This paper is devoted towards life cycle economic analysis (LCEA) of a solar photovoltaic (PV) powered tri-cycle. The paper is meant to propose a more systematic approach in determining the optimum use of scarce resources in order to determine the most cost-effective option of the solar tri-cycle. This analysis is based on the life cycle cost of this solar vehicle, involving its comparison with the customary fuel-based tri-cycle which exhibits the relatively less expenditure of the solar alternative. The economic analysis takes into account the fact that over 20 years, the overall price of solar component, replacement and electricity charges, is much lower as compared to that of a fuel-based tri-cycle in India taking into consideration the fuel cost, maintenance and annual inflation over the same period.
The transformer-less grid connected inverters are gaining more popularity due to their high efficiency, very low ground leakage current and economic feasibility especially in photovoltaic systems. The major issue which surfaces these systems is that of common mode leakage current which arises due to the absence of an electrical transformer connected between the inverter and the utility grid. Several topologies have evolved to reduce the impact of common mode leakage current and a majority of them have succeeded in eliminating the impacts and have well kept them within the limits of grid standards. This paper compares and analyses the impact of the common mode leakage current for four popular inverter configurations through simulation of the topologies such as H5, H6, HERIC and FBZVR inverters.
A novel phase shift full bridge (PSFB) converter with voltage-doubler and decoupling integrated magnetics in photovoltaic (PV) systems is proposed. Considering the demand that the output voltage is higher than the input voltage in PV systems, the voltage-doubler is added to achieve higher voltage gain compared with the traditional PSFB. In order to avoid current oscillation caused by the voltage-doubler and obtain the wide zero voltage switching (ZVS) ranges, an external inductor is imposed on the circuit. Especially, to obtain much higher power density, the external inductor and transformer are integrated into one magnetic core. The operation and voltage gain of proposed converter are analyzed. Also, in order to reveal the effects the integrated magnetics gives to the converter, the decoupling condition and the expression of leakage inductor of integrated magnetics are obtained in detail. Finally a 100 W prototype converter is made and the experimental results are given to verify the analysis.
Solar energy is widely available in nature and electricity can be easily extracted using solar PV cells. A fuel cell being reliable and environment friendly becomes a good choice for the backup so as to compensate for continuously varying solar irradiation. This paper presents simple control schemes for power management of the DC microgrid consisting of PV modules and fuel cell as energy sources and a hydrogen electrolyzer system for storing the excess power generated. The supercapacitor bank is used as a short term energy storage device for providing the energy buffer whenever sudden fluctuations occur in the input power and the load demand. A new power control strategy is developed for a hydrogen storage system. The performance of the system is assessed with and without the supercapacitor bank and the results are compared. A comparative study of the voltage regulation of the microgrid is presented with the controller of the supercapacitor bank, realized using a traditional PI controller and an intelligent fuzzy logic controller.
In a PV-dominant DC microgrid, the traditional energy distribution method based on the droop control method has problems such as output voltage drop, insufficient power distribution accuracy, etc. Meanwhile, different battery energy storage units usually have different parameters when the system is running. Therefore, this paper proposes an improved control method that introduces a reference current correction factor, and a weighted calculation method for load power distribution based on the parameters of battery energy storage units is proposed to achieve weighted allocation of load power. In addition, considering the variation of bus voltage at the time of load mutation, voltage secondary control is added to realize dynamic adjustment of DC bus voltage fluctuation. The proposed method can achieve balance and stable operation of energy storage units. The simulation results verified the effectiveness and stability of the proposed control strategy.
The process of synchronization of synchronous generators and power electronic converters with the power grid may take on quite different forms. This is due to their specific principles of operation and essential differences in energy conversion process. However, since synchronous generators and power converter often operate in the same utility network, coherent rules should be defined for them. Therefore, this paper aims at a formulation of the uniform and consistent interpretation of synchronization with the power grid for both types of aforementioned units. The author starts from the classic interpretation of synchronization for synchronous generators and power electronic converters, considered as micro-generators, specifies their mathematical and numerical models and then performs simulation tests. Selected synchronization algorithms are described in detail. Simulation tests are used for analysis of the elaboration of outcomes. The results of simulation tests are handled to formulate a uniform interpretation of synchronization for the micro-generation systems considered. Based on the results obtained, appropriate parallels are built between the two systems being compared. It is shown that the synchronization processes are identical regardless of the micro-generation unit considered. Nonetheless, they differ significantly due to their properties in transient states. Inverter systems have higher dynamics but their disadvantage lies in the relatively high sensitivity to disturbances and the complex selection process of the synchronization algorithm.
Architecture is a discipline combining aesthetics with technology. This paper is focusing on the relationship between aesthetics and energy efficiency in architecture with special interest in solar collectors and photovoltaic panels as technological equipment of the buildings. The paper takes into consideration the present situation and architectural development in northern Poland, with some input basing on European experiences. The paper defi nes aesthetics and effi ciency in the field of architectural design as well as the use of public and urban spaces. Authors present also some case studies regarding the use of solar panels in selected architectural examples. The paper ends with summary and some conclusions including the need for further research in the field of architectural design, technology and product design, as well as the perception of urbanised spaces and the important field of economic and financial factors connected to the topic.
This study set out to investigate, for the first time, the distribution and colocalization pattern of cocaine-and amphetamine-regulated transcript (CART) and one of the calcium binding-proteins: parvalbumin (PV) in the chinchilla’s hippocampus proper (HP). HP, consisting of Ammon’s horn (CA) and the dentate gyrus (DG), is an important component of the limbic system, involved in learning and memory processes. CA showed a higher immunoreactivity of CART (-IR) compared to DG. CART-IR neurons were mainly observed in the molecular layer of DG and in the pyramidal layer of CA. CART-IR fibers were present in the granular layer; in the hilus numerous mossy fibers were detected, while in the molecular layer CART-IR fibers were not found. In all CA fields (CA1-CA3), CART-IR fibers were only present in the lacuno- sum-molecular layer. Immunofluorescence with double- labeling showed that only CART-IR cells stained positive for PV, whereas in CART-IR fibers there was no PV-positive reaction. Our research supplements missing knowledge about the distribution and colocalization pattern of CART with PV in the chinchilla’s hippocampus, and also provides a better understanding of the similarities and differences among individuals of the same species and also with other mammals.
The grid integration of large-scale wind and solar energy affects the power flow of wind-PV-thermal-bundled power transmission systems and may introduce an unpredicted threat to the power system’s small signal stability. Meanwhile, a power system stabilizer (PSS) and static synchronous series compensator (SSSC) play an important role in improving the static and dynamic stability of the system. Based on this scenario and in view of the actual engineering requirements, the framework of wind-PV-thermal-bundled power transmitted by an AC/DC system with the PSS and SSSC is established considering the fluctuation of wind and photovoltaic power output and the characteristics of the PSS and SSSC. Afterwards, the situation model is constructed in the IEEE 2-area 4-unit system, and the influence of the PSS and SSSC on the system stability under different operating conditions is analyzed in detail through eigenvalue analysis and time-domain simulation. Finally, an index named the gain rate is defined to describe the improvement of the stability limitations of various wind-PV-thermal operating conditions with the PSS and SSSC. The results indicate (K) that the damping characteristics, dynamic stability and stability limitations for various wind-PV-thermal operating conditions of the wind-PV-thermal-bundled power transmission system can be significantly improved by the interaction of the PSS and SSSC.