Applied sciences

Metrology and Measurement Systems

Content

Metrology and Measurement Systems | 2015 | vol. 22 | No 1

Download PDF Download RIS Download Bibtex

Abstract

An array consisting of four commercial gas sensors with target specifications for hydrocarbons, ammonia, alcohol, explosive gases has been constructed and tested. The sensors in the array operate in the dynamic mode upon the temperature modulation from 350°C to 500°C. Changes in the sensor operating temperature lead to distinct resistance responses affected by the gas type, its concentration and the humidity level. The measurements are performed upon various hydrogen (17-3000 ppm), methane (167-3000 ppm) and propane (167-3000 ppm) concentrations at relative humidity levels of 0-75%RH. The measured dynamic response signals are further processed with the Discrete Fourier Transform. Absolute values of the dc component and the first five harmonics of each sensor are analysed by a feed-forward back-propagation neural network. The ultimate aim of this research is to achieve a reliable hydrogen detection despite an interference of the humidity and residual gases.
Go to article

Authors and Affiliations

Patryk Gwiżdż
Andrzej Brudnik
Katarzyna Zakrzewska
Download PDF Download RIS Download Bibtex

Abstract

As it contains elements of complete digital impedance meter, the AD5933 integrated circuit is an interesting solution for impedance measurements. However, its use for measurements in a wide range of impedances and frequencies requires an additional digital and analogue circuitry. This paper presents the design and performance of a simple impedance meter based on the AD5933 IC. Apart from the AD5933 IC it consists of a clock generator with a programmable prescaler, a novel DC offset canceller for the excitation signal based on peak detectors and a current to voltage converter with switchable conversion ratios. The authors proposed a simple method for choosing the measurement frequency to minimalize errors resulting from the spectral leakage and distortion caused by a lack of an anti-aliasing filter in the DDS generator. Additionally, a novel method for the AD5933 IC calibration was proposed. It consists in a mathematical compensation of the systematic error occurring in the argument of the value returned from the AD5933 IC as a result. The performance of the whole system is demonstrated in an exemplary measurement.
Go to article

Authors and Affiliations

Konrad Chabowski
Tomasz Piasecki
Andrzej Dzierka
Karol Nitsch
Download PDF Download RIS Download Bibtex

Abstract

Ambient concentrations of CO, as well as NOx and O3, were measured as a part of the PARADE campaign conducted at the Taunus Observatory on the summit of the Kleiner Feldberg between the 8th of August and 9th of September 2011. These measurements were made in an effort to provide insight into the characteristics of the effects of both biogenic and anthropogenic emissions on atmospheric chemistry in the rural south-western German environment. The overall average CO concentration was found to be 100.3±18.1 ppbv (within the range of 71 to 180 ppbv), determined from 10-min averages during the summer season. The background CO concentration was estimated to be ~90 ppbv. CO and NOx showed bimodal diurnal variations with peaks in the late morning (10:00-12:00 UTC) and in the late afternoon (17:00-20:00 UTC). Strong correlations between CO and NOx indicated that vehicular emission was the major contributor to the notable CO plumes observed at the sampling site. Both local meteorology and backward trajectory analyses suggest that CO plumes were associated with anthropogenically polluted air masses transferred by an advection to the site from densely populated city sites. Furthermore, a good linear correlation of R2 = 0.54 between CO and O3 (∆O3/∆CO=0.560±0.016 ppbv/ppbv) was observed, in good agreement with previous observations
Go to article

Authors and Affiliations

Jingsong Li
Andreas Reiffs
Uwe Parchatka
Horst Fischer
Download PDF Download RIS Download Bibtex

Abstract

To reduce the influence of the static unbalance on an infrared missile guidance system, a new static unbalance measure system for the gimbals axes has been developed. Considering the coupling effects caused by a mass eccentricity, the static balance condition and measure sequence for each gimbal axis are obtained. A novel static unbalance test approach is proposed after analyzing the dynamic model of the measured gimbal axis. This approach is to drive the measured gimbal axis to do sinusoidal reciprocating motion in a small angle and collect its drive currents in real time. Then the static unbalance of the measured gimbal axis can be obtained by the current multi-cycle integration. Also a measuring system using the proposed approach has been developed. A balanced simulator is used to verify the proposed approach by the load and repeatability tests. The results show the proposed approach enhances the efficiency of the static unbalance measurement, and the developed measuring system is able to achieve a high precision with a greater stability.
Go to article

Authors and Affiliations

Hui Yang
Yan Zhao
Min Li
Falin Wu
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a technique for measuring membrane displacements with one motionless camera. The method consists in measuring the distance to an object based on one image obtained from a motionless camera with a fixed-focus lens. The essence of the proposed measurement technique is to determine changes of the distance between a membrane and a video camera based on analysis of changes in the focus view of a marker placed on the membrane plane. It is proven that the used technique allows to monitor the frequency and amplitude of the membrane vibration. The tests were performed for the oscillation frequency in the range from 0.5 Hz to 6 Hz and deviations from the neutral position in the range of ±3 mm.
Go to article

Authors and Affiliations

Krzysztof Murawski
Download PDF Download RIS Download Bibtex

Abstract

This paper presents a new test method able to infer - in periods of less than 7 seconds - the refrigeration capacity of a compressor used in thermal machines, which represents a time reduction of approximately 99.95% related to the standardized traditional methods. The method was developed aiming at its application on compressor manufacture lines and on 100% of the units produced. Artificial neural networks (ANNs) were used to establish a model able to infer the refrigeration capacity based on the data collected directly on the production line. The proposed method does not make use of refrigeration systems and also does not require using the compressor oil.
Go to article

Authors and Affiliations

Rodrigo Coral
Carlos A. Flesch
Cesar A. Penz
Maikon R. Borges
Download PDF Download RIS Download Bibtex

Abstract

This paper deals with the amplitude estimation in the frequency domain of low-level sine waves, i.e. sine waves spanning a small number of quantization steps of an analog-to-digital converter. This is a quite common condition for high-speed low-resolution converters. A digitized sine wave is transformed into the frequency domain through the discrete Fourier transform. The error in the amplitude estimate is treated as a random variable since the offset and the phase of the sine wave are usually unknown. Therefore, the estimate is characterized by its standard deviation. The proposed model evaluates properly such a standard deviation by treating the quantization with a Fourier series approach. On the other hand, it is shown that the conventional noise model of quantization would lead to a large underestimation of the error standard deviation. The effects of measurement parameters, such as the number of samples and a kind of the time window, are also investigated. Finally, a threshold for the additive noise is provided as the boundary for validity of the two quantization models
Go to article

Authors and Affiliations

Diego Bellan
Download PDF Download RIS Download Bibtex

Abstract

The vapour pressure of most explosives is very low. Therefore, the explosive trace detection is very difficult. To overcome the problem, concentration units can be applied. At the Institute of Optoelectronics MUT, an explosive vapour concentration and decomposition unit to operate with an optoelectronic sensor of nitrogen dioxide has been developed. This unit provides an adsorption of explosive vapours from the analysed air and then their thermal decomposition. The thermal decomposition is mainly a chemical reaction, which consists in breaking up compounds into two or more simple compounds or elements. During the heating process most explosive particles, based on nitro aromatics and alkyl nitrate, release NO2 molecules and other products of pyrolysis. In this paper, the most common methods for the NO2 detection were presented. Also, an application of the concentration and decomposition unit in the NO2 optoelectronic sensor has been discussed.
Go to article

Authors and Affiliations

Beata Zakrzewska
Download PDF Download RIS Download Bibtex

Abstract

A sensing system utilizing a standard optical fiber as a distributed sensor for the detection and localization of mechanical vibrations is presented. Vibrations can be caused by various external factors, like moving people, cars, trains, and other objects producing mechanical vibrations that are sensed by a fiber. In our laboratory we have designed a sensing system based on the Φ-OTDR (phase sensitive Optical Time Domain Reflectometry) using an extremely narrow laser and EDFAs.
Go to article

Authors and Affiliations

Radim Sifta
Petr Munster
Petr Sysel
Tomas Horvath
Vit Novotny
Ondrej Krajsa
Miloslav Filka
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a study of the performance of some selected UV detectors. Unlike many similar works, the obtained data refer to commercial photodiodes (not only to detector materials). The main task of the research was to determine the influence of the operating temperature and annealing on the detector spectral responsiveness. A comparison of the results obtained for the photodiodes made of GaN and SiC was also performed. Although both kinds of detectors can work at high temperatures for a long time, some modification of their properties was observed. However, for GaN and SiC photodiodes, this modification has a substantially different nature. It is very important for some applications, e.g. fire alarms and a military equipment.
Go to article

Authors and Affiliations

Joanna Ćwirko
Robert Ćwirko
Janusz Mikołajczyk
Download PDF Download RIS Download Bibtex

Abstract

The aim of this study was to assess the innovation risk for an additive manufacturing process. The analysis was based on the results of static tensile tests obtained for specimens made of photocured resin. The assessment involved analyzing the measurement uncertainty by applying the FMEA method. The structure of the cause