TY - JOUR N2 - The touch trigger probe plays an important role in modern metrology because of its robust and compact design with crash protection, long life and excellent repeatability. Aside from coordinate measuring machines (CMM), touch trigger probes are used for workpiece location on a machine tool and for the accuracy assessment of the machine tools. As a result, the accuracy of the measurement is a matter of interest to the users. The touch trigger probe itself as well as the measuring surface, the machine tool, measuring environment etc. contribute to measurement inaccuracies. The paper presents the effect of surface irregularities, surface wetness due to cutting fluid and probing direction on probing accuracy on a machine tool. L1 - http://www.czasopisma.pan.pl/Content/104282/PDF/ame-2016-0028.pdf L2 - http://www.czasopisma.pan.pl/Content/104282 PY - 2016 IS - No 4 EP - 510 DO - 10.1515/meceng-2016-0028 KW - probing KW - machine tool KW - touch probe KW - repeatability KW - measurement inaccuracy A1 - Rahman, Md. Mizanur A1 - Mayer, J.R.R. PB - Polish Academy of Sciences, Committee on Machine Building VL - vol. 63 DA - 2016.12.17 T1 - Measurement accuracy investigation of touch trigger probe with five-axis machine tools SP - 495 UR - http://www.czasopisma.pan.pl/dlibra/publication/edition/104282 T2 - Archive of Mechanical Engineering ER -