@ARTICLE{Brzeziński_M._Applications_2012, author={Brzeziński, M. and Ziółkowski, E. and Wrona, R. and K. Smyksy and Zyzak, P.}, number={No 2}, journal={Archives of Foundry Engineering}, howpublished={online}, year={2012}, publisher={The Katowice Branch of the Polish Academy of Sciences}, abstract={Vacuum conditions in foundry installations are generated using electric-driven vacuum pumps. The purpose of the experiment is to evaluate the performance of a vacuum-assisted system for compaction of moulding sand basing on registered plots of selected electric power parameters of the power-supplying system of the pumps. Model testing done on an experimental vacuum system installation, power-supplied from a system incorporating the recorders of instantaneous current and voltage values. Following the numerical procedure, the experimental data are analysed to yield mathematical relationships between the variations of the generated vacuum pressure levels and variations of selected electric power parameters. Registered and computed values of selected parameters: instantaneous and RMS voltage and current values, active, reactive and apparent power levels and power coefficient allow for diagnosing the adequacy and reliability of the system operation. According to the authors, the applied monitoring of the power parameters of a vacuum-assisted installation may become an effective and easy practical method of evaluating the performance of such installations, used also in foundry plants.}, type={Artykuły / Articles}, title={Applications of Monitoring of Electric Power Parameters to Performance Evaluation of a Model Vacuum-Assisted Moulding Installation}, URL={http://www.czasopisma.pan.pl/Content/86884/PDF/46_paper.pdf}, doi={10.2478/v10266-012-0071-4}, keywords={Mechanisation and Automation of Foundry Processes, Electric Power Measurements, Vacuum-Assisted Moulding Processes}, }