Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Water is the main source of daily life for everyone and everywhere in the world. Sufficient water distribution depends on the place and design of water tank in certain areas. Water storage tanks are relatively flexible structures and they can tolerate greater settlements than other engineering structures. Deformation of tanks may cause severe damages to tank or even loss of life and injury to people, so monitoring the structural deformation and dynamic response of water tank and its supporting system to the large variety of external loadings has a great importance for maintaining tank safety and economical design of manmade structures. This paper presents an accurate geodetic observations technique to investigate the inclination of an elevated circular water tank and the deformation of its supporting structural system (supporting columns and circular horizontal beams) using reflector-less total station. The studied water tank was designed to deliver water to around 55000 person and has a storage capacity about 750 m3. Due to the studied water tank age, a non-uniform settlement of tank foundation and movement of pumps and electric machines under tank’s body will cause stress and strain for tanks membrane and settlement of sediments. So the studied water tank can tend to experience movement vertically, horizontally or both. Three epochs of observations were done (July 2014, September 2014 and December 2014). The results of the practical measurements, calculations and analysis of the interesting deformation of the studied elevated tanks and its supporting system using least squares theory and computer programs are presented. As a results of monitoring the water storage tank, circular reinforced concrete beams and columns at three monitoring epochs. The body of water storage tank has an inclination to the east direction and the value of inclination is increased with the time.

Go to article

Authors and Affiliations

Zaki Zeidan
Ashraf A.A. Beshr
Sara Sameh
Download PDF Download RIS Download Bibtex

Abstract

The analysis of a solar installation operation was conducted on the example of a detached house in the Lesser Poland province in Poland. A gas boiler and three flat-plate collectors are located inside the house, which are used for heating water in the hot water tank with a volume of 220 dm3. The installation was established in 2012. The heat measured system (for solar gains) was added in 2014. In 2015–2019 solar heat gains measured per area of absorber were higher than 340 kWh/m2. During a two-week period in June 2015, the insolation on the horizontal plane and the temperature were measured in 4 different points of the hot water tank. On this basis, heat losses from the storage tank were determined, i.e. a decrease in temperature during periods with and without the consumption of hot water by the residents. During this period, a temperature higher than 80°C was observed several times in the hot water tank. In two parts of the hot water tank, rhe determined temperature decreases were used to obtain the heat loss amount. In the analyzed period (2 weeks), 9 days were observed with solar heat gains higher than 9 kWh/day. For these days, the value of heat loss from the solar hot water tank was estimated at over 6 kWh/day. This data corresponds to the actual heat demand for hot water preparation in the building at 7.3 kWh/day. The correlation between daily solar heat gains and solar hot water tank heat losses were also determined. In addition, based on the amount of heat losses, the value of the tank loss coefficient was estimated. The obtained value was compared with the manufacturer’s data and reference data.

Go to article

Authors and Affiliations

Piotr Olczak
ORCID: ORCID

This page uses 'cookies'. Learn more