Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 14
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The primary objective of the present study was to determine the seasonal dynamics of ciliates in activated sludge. Studies were carried out in order to verify the hypothesis that fertility of a habitat may significantly influence the seasonal dynamics of the abundance of ciliates, as well as the number and intensity of correlations between physic-chemical parameters and ciliates. It seems that the values of numbers of ciliates were seasonally changeable. The highest numbers of ciliates were found in spring and summer, however the lowest numbers of ciliate communities were noted in winter. The studies showed that protozoa community is determined by ammonia mainly in summer. In spring and winter additional factors may be important. Probably suspended solid, total organic carbon and concentration of appropriate food (bacteria and flagellates) are the major regulator of abundance of ciliates.
Go to article

Authors and Affiliations

Monika Tarkowska-Kukuryk
Tomasz Mieczan
Wojciech Pęczuła
Jacek Rechulicz
Wojciech Płaska
Katarzyna Radomska
Download PDF Download RIS Download Bibtex

Abstract

The paper presents preliminary results of investigations on a relationship between turbidity and other quality parameters in the SBR plant effluent. The laboratory tests demonstrated a high correlation between an effluent turbidity and a total suspended solids (TSS) concentration as well as between TSS and COD. Such a relationship would help to continuously monitor and control quality of a wastewater discharge using turbidity measurement.

Go to article

Authors and Affiliations

Zbigniew Mucha
Przemysław Kułakowski
Download PDF Download RIS Download Bibtex

Abstract

The aim of this study was to determine the impact of the temperature of wastewater in a biological reactor with activated sludge and the BOD5/N-NH4 ratio in the influent to the treatment plant on nitrification efficiency and the concentration of ammonium nitrogen in treated wastewater. Tests were carried out in a household wastewater treatment plant which collects and treats sewage from a school building and a teacher’s house. During the 3-year study, large fluctuations in the sewage temperature in bioreactor were noted which was closely related to the ambient temperature. There were also large fluctuations in the concentration of organic matter and the concentration of ammonium nitrogen in inflowing sewage. The influence of wastewater temperature in the bioreactor and the BOD5/N-NH4 ratio on the concentration of ammonium nitrogen in treated wastewater was determined using Pearson’s linear correlation. A statistical analysis showed that a 1°C decrease in the temperature of wastewater in the bioreactor increased the concentration of ammonium nitrogen in treated wastewater by 2.64 mgN-NH4·L-1. Moreover, it was found that nitrification depended on the ratio of BOD5 to the concentration of ammonium nitrogen in wastewater flowing into the bioreactor. An increase in the BOD5/N-NH4 ratio by 1 value led to a 5.41 mgN-NH4·L-1 decrease in the concentration of ammonium nitrogen.

Go to article

Authors and Affiliations

Piotr Bugajski
Karolina Kurek
Krzysztof Jóźwiakowski
Download PDF Download RIS Download Bibtex

Abstract

The aim of the study was to evaluate the possibility of applying different methods of data mining to model the inflow of sewage into the municipal sewage treatment plant. Prediction models were elaborated using methods of support vector machines (SVM), random forests (RF), k-nearest neighbour (k-NN) and of Kernel regression (K). Data consisted of the time series of daily rainfalls, water level measurements in the clarified sewage recipient and the wastewater inflow into the Rzeszow city plant. Results indicate that the best models with one input delayed by 1 day were obtained using the k-NN method while the worst with the K method. For the models with two input variables and one explanatory one the smallest errors were obtained if model inputs were sewage inflow and rainfall data delayed by 1 day and the best fit is provided using RF method while the worst with the K method. In the case of models with three inputs and two explanatory variables, the best results were reported for the SVM and the worst for the K method. In the most of the modelling runs the smallest prediction errors are obtained using the SVM method and the biggest ones with the K method. In the case of the simplest model with one input delayed by 1 day the best results are provided using k-NN method and by the models with two inputs in two modelling runs the RF method appeared as the best.

Go to article

Authors and Affiliations

Bartosz Szeląg
Lidia Bartkiewicz
Jan Studziński
Krzysztof Barbusiński
Download PDF Download RIS Download Bibtex

Abstract

Microbiological studies were carried out of atmospheric air sampled on the area and in the surroundings of a mechanical and biological wastewater treatment plant (WTP) treating municipal sewage. The capacity of the wastewater treatment plant, which also received some wastewater from the dairy industry, was ca 3· 103 m3d-1. Counts ofheterotrophic psychrophilic, psychrotrophic and mesophilic bacteria as well as some physiological groups of microorganisms which belong to Enterobacteriaceae family, Staphylococcus and Enterococcus genera, Pseudomonas fluorescens and P. aeruginosa species, hemolysing bacteria and actinomycetes were analyzed. Air samples were collected in summer, autumn, winter and spring seasons simultaneously by the sedimentation and impact methods at 6 sites located on the area of the WTP and at 5 sites situated in its surroundings. The background was established depending on the direction of wind, always on the windward side in relation to the location of the WTP. In addition, temperature and air humidity as well as wind speed and direction at each sampling sites were observed. Statistically significant differences were found in studied groups of microorganisms counts between air samples collected in different seasons of the year (with the exception of psychrophilic bacteria and by the two different methods (with the exception of psychrophilic bacteria) and microorganisms which belong to Enterobacteriaceae family). The highest mean counts of the microorganisms were usually determined in air samples collected by the sedimentation method, especially during the autumn (with the exception of actinomycetes, which are the most numerous in spring), the lowest ones in winter and/or in summer. No statistically significant differences were observed in counts of the analyzed groups of microorganisms in air sampled at particular sites (with the exception of Enterobacteriaceae bacteria isolated on Chromocult medium). However, higher counts of these microorganisms were typically found in the air sampled in the area of the WTP, particularly near the grit chamber, phosphorus removal tank, nitrification and denitrification chambers and secondary settling tank. According to the Polish Standards used for evaluation of atmospheric air pollution, the air sampled in the area of wastewater treatment plant and in its surroundings was classified as only slightly and sporadically strongly polluted. It was mainly in the spring and autumn seasons that the air was strongly polluted with psychrophilic and mesophilic bacteria. No increased emission of the analyzed groups of microorganisms, including faecal bacteria was determined in the air samples collected outside the WT
Go to article

Authors and Affiliations

Ewa Korzeniewska
Zofia Filipkowska
Anna Gotkowska-Płachta
Wojciech Janczukowicz
Bartosz Rutkowski
Download PDF Download RIS Download Bibtex

Abstract

The remarkable development of sanitation in Morocco has inevitably led to the production of sludge generated from wastewater treatment plants in increasing quantities. Consequently, the problem of sludge management becomes persistent and worrying.

The aim of this paper was to contribute to the study of sewage sludge management issue in Morocco by identifying the various constraints hampering the sustainable disposal and/or recovery of municipal sewage sludge and drawing up rec-ommendations for the decision-makers. Moreover, in the context of improving by learning from best practices and seeking common solutions regarding this problematic, benchmarking with other countries has been conducted as well.

To carry out this study, a methodological approach was defined based on bibliographic research, surveys, interviews and benchmarking.

The constraints hampering the sustainable management of sludge are numerous and complex, they have not been tech-nical and environmental but also a regulatory, institutional-organizational and economic-financial nature yet. Therefore, municipalities, government and academia ideally would be encouraged to participate in the decision-making process re-garding the management of sewage sludge. Technical solutions, when coupled with stakeholder participation, can lead to policy implementation with a higher chance of improving the present situation.

In the case of Morocco, when comparing with others sludge recovery and disposal routes, land application (reuse in ag-riculture, silviculture and rehabilitation of degraded soils) remains the most environmentally friendly option, as well as a sustainable and economically viable solution.

Go to article

Authors and Affiliations

Abdessamad Ghacha
Lailal Ben Alla
Mohammed Ammari
Download PDF Download RIS Download Bibtex

Abstract

The aim of the work was to determine the technological reliability of the selected pollution indicators removal BOD5, CODCr and total suspension from the sewage treatment plant working with the bioreactor Pomiltek Mann type. Wastewater treatment plant which is a subject of this study is located in Lesser Poland, in Siepraw commune. The analysis was per-formed using the Weibull method for basic indicators of impurities, BOD5, CODCr and total suspended solids. Physico-chemical analyses of raw and treated wastewater, were carried out in the period from 2003 to 2014 (11 years). The research period included measured values of pollutions indicators in 38 samples of raw and treated sewage. For each of pollution indicators descriptive statistic, percentage reduction (��) and treatment plant reliability factors (RF) were calculated. Aver-age reduction for BOD5 and TSS was on level equal 94%, only for COD the average reduction was lower and was on level 89%. The reliability values determined by Weibull method, were: 75% (BOD5), 90% (CODCr) and 89.5% (TSS). The relia-bility results have been lower than the presented by literature source, which means that work of wastewater treatment plant in Siepraw was not satisfied in 11 years of research.

Go to article

Authors and Affiliations

Karolina Kurek
Piotr Bugajski
ORCID: ORCID
Agnieszka Operacz
ORCID: ORCID
Dariusz Młyński
Andrzej Wałęga
Download PDF Download RIS Download Bibtex

Abstract

In many wastewater treatment plants (WWTPs) inconveniences resulting from foam formation on the surface of activated sludge wastewater treatment devices appear. Foaming phenomenon is related to the characteristics of raw sewage and applied technological parameters of activated sludge process which promote the development of specific foam-forming filamentous microorganisms. In bulking activated sludges there are about 30 species of filamentous microorganisms and in the foam not more than about 1 O species. Basic method of identification of filamentous microorganisms present in foam are microscopic investigations which can be performed both in vivo by direct observation of no stained, so called living smears, with contrast - phase device and in stained smears alter different stain methods in direct light or dark field.
Go to article

Authors and Affiliations

Liliana Kalisz
Marcin Każrnierczuk
Download PDF Download RIS Download Bibtex

Abstract

This work aims to evaluate the treated wastewater from the activated sludge treatment plant in the City of Sidi Bel Ab-bes (North-Western Algeria) which is required for reuse in irrigation. The control of irrigated areas downstream is done based on a pedological study. Physico-chemical analysis such as (pH, BOD5, COD and SS) indicate results in Algerian and international standards required by the WHO. The Sodium Adsorption Ratio and Electrical Conductivity values of the treated wastewater belong to the C3-S1 class. The treated wastewater has a fairly good microbiological quality that meets Algerian standards. The helminth eggs are practically absent. The concentrations of heavy metals are much lower than the limits prescribed in the Algerian decrees. Therefore, the overall processing plant efficiency is satisfactory and has the char-acteristics of a good treated water quality for reuse in the field of irrigation while protecting the environment. The pedolo-gical study of the soil samples shows that the most dominant fraction is undeveloped calcimagnetic. The planned irrigation plain covers an area of about two thousand hectares. Depending on the crops to irrigate; the development and nature of the necessary or recommended improvements, the proposed irrigation perimeter could be classified into five categories in which only three categories are irrigable. Water projects have been proposed to ensure the irrigation of three subdivided sectors.

Go to article

Authors and Affiliations

Zakari Mahfoud
Download PDF Download RIS Download Bibtex

Abstract

The objective of this experimental study was to examine whether an assisting layer of lightweight expanded clay aggregate (LECA) of the granulation 1–4 mm, introduced into a subsoil, is able to improve an efficiency of removal of total nitrogen and total phosphorus from domestic wastewater. In the investigations, an assisting 0.10 and 0.20 m thick LECA layer was applied. It has been observed that the effectiveness of removal of total suspended solids (TSS), total nitrogen and total phosphorus from wastewater as well as the level of biochemical oxygen demand ( BOD 5) and chemical oxygen demand ( COD) is in accordance with the Polish standards on wastewater disposal into grounds and surface water. The performed experiments showed that the effectiveness of raw wastewater purification for the medium sand soil bed with the 0.20 m thick assisting LECA layer is higher than for the 0.10 m thick assisting layer. In the medium sand soil bed with the 0.20 m thick assisting LECA layer, the removal efficiency regarding total nitrogen increased by 20.6%, total phosphorus by 5.2%, ammonium nitrogen by 8.8% and TSS by 5.3%, and reduction efficiency regarding BOD 5 increased by 1.7% and COD by 2.3% with relation to the 0.10 m thick assisting LECA layer (all percentages – in average). The results of the experiment showed that the LECA with the granulation 1–4 mm can be used to assist in removal of total nitrogen and total phosphorus from wastewater with application of infiltration drainage.
Go to article

Authors and Affiliations

Marek Kalenik
1
ORCID: ORCID
Piotr Wichowski
1
ORCID: ORCID
Marek Chalecki
2
ORCID: ORCID
Adam Kiczko
1
ORCID: ORCID

  1. Warsaw University of Life Sciences – SGGW, Institute of Environmental Engineering, Department of Hydraulics and Sanitary Engineering, Nowoursynowska 159, 02-776 Warsaw, Poland
  2. Warsaw University of Life Sciences – SGGW, Institute of Civil Engineering, Department of Mechanics and Building Structures, Warsaw, Poland