Random nature of corona processes in UHV power lines and the accompanying noise is the reason that in practice the best determination of acoustic parameters, necessary for the noise evaluation, is obtained from the continuous monitoring procedure. However because of considerable fluctuations (both the useful signal part and the interfering components), careful selection of monitored parameters is necessary to enable a possibility of automatic determination of the parameters that are required for long-term evaluation of corona noise.
In the present work a practical realization is shown for estimation of corona noise parameters, based on the data obtained from continuous monitoring stations, making use of the statistical spectra measurement and characteristic features of corona process acoustic signal.
Selected results are presented from continuous monitoring of corona noise generated at a 400 kV power line, with special attention focused on definitions of the measured quantities, which enable automatic estimation of the basic factors required for noise evaluation. Accompanying monitoring of environmental conditions, including humidity, precipitation intensity and fog density, that are well correlated with the corona process intensity, which might definitely increase the filtration efficiency of environmental disturbances and on the other hand, it enables verification of calculation methods applied to corona noise.
The paper also contains a description of practical approach to selection signal parameters of corona noise in continuous monitoring stations.
Arriving at a good combination of coding and modulation schemes that can achieve good error correction constitutes a challenge in digital communication systems. In this work, we explore the combination of permutation coding (PC) and pulse amplitude modulation (PAM) for mitigating channel errors in the presence of background noise and jitter. Since PAM is characterised with bi-polar constellations, Euclidean distance is a good choice for predicting the performance of such coded modulation setup. In order to address certain challenges facing PCs, we therefore introduce injections in the coding system, together with a modified form of PAM system. This modification entails constraining the PAM constellations to the size of the codeword’s symbol. The results obtained demonstrate the strength of the modified coded PAM system over the conventional PC coded PAM system.
Low-power consumption and long-distance transmission are two problems that have to be solved by the application of broadband power line communication for the automatic meter reading system. To reduce the power consumption of the communication module, based on the analysis of the composition of the power consumption, some methods are proposed. From the communication chip level and the module circuit level, the design scheme of low-power consumption is given. To solve the problem of transmission distance, a frequency band of 2.44 MHz~5.6 MHz is used as the main working frequency band. The communication module supports multiple frequency bands. Using this feature, the optimal frequency band is adaptively selected for communication and automatic switching, which further improve the transmission distance. Field application shows that the above methods effectively decrease the power consumption of the communication module and extend the transmission distance.
To overcome the detrimental influence of α impulse noise in power line communication and the trap of scarce prior information in traditional noise suppression schemes , a power iteration based fast independent component analysis (PowerICA) based noise suppression scheme is designed in this paper. Firstly, the pseudo-observation signal is constructed by weighted processing so that single-channel blind separation model is transformed into the multi-channel observed model. Then the proposed blind separation algorithm is used to separate noise and source signals. Finally, the effectiveness of the proposed algorithm is verified by experiment simulation. Experiment results show that the proposed algorithm has better separation effect, more stable separation and less implementation time than that of FastICA algorithm, which also improves the real-time performance of communication signal processing.