Abstract

Three-level T-type inverters have lower total harmonic distortion in output voltage, higher power density and lower voltage stress of power switches compared with conventional two-level inverters and have been widely used in applications with a wide-power range. Reliability improvement is particularly important for the T-type inverters because of the increased number of power switches and high system complexity. This paper proposes a fault-tolerant topology, which is constructed by adding a redundant leg including halfbridge switches and neutral-point switches connected between the DC bus capacitors and the DC-link midpoint of the conventional T-type inverter. In addition, an after-fault control strategy is proposed based on the results of a fault diagnosis method using bridge voltage. The fault-tolerant control of the open-circuit fault of the power switches and the phase-leg fault can both be achieved by the proposed method. Experimental results are given to verify that the proposed fault-tolerant three-level T-type inverter can output the full voltage level and power during the fault-tolerant operation based on the proposed control strategy.
Go to article

Authors and Affiliations

Danjiang Chen
1
ORCID: ORCID
Liyuan Zheng
1
ORCID: ORCID

  1. College of Information and Intelligence Engineering, Zhejiang Wanli University, No. 8, South Qian Hu Road, Ningbo, Zhejiang, China 315100