Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 300
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The article describes the methodology for the determination of ambient temperature for thermovision measurements. The adopted methodology consists in the use of the technical blackbody model. Determining the value of the ambient temperature parameter makes it possible to enhance the accuracy of temperature measurement of objects exposed to strong irradiation using a thermovision camera.

Go to article

Authors and Affiliations

Rafał Wyczółkowski
Dorota Musiał
Download PDF Download RIS Download Bibtex

Abstract

Worldwide Interoperability for Microwave Access (WiMAX), based on the IEEE 802.16 standards, is a technology that offers low cost mobile broadband access to multimedia and internet applications for operators and end-users. Similarly to cellular phone or other Radio Frequency devices, WiMAX has to be considered as a possible source of electromagnetic pollution and so monitoring its emission could be necessary to verify compliance with the applicable emission limits. Generally, the monitoring of the electromagnetic pollution is performed by means of a suitable measurement chain constituted by an antenna connected to a traditional spectrum analyzer. The use of this kind of device to measure the power of digital modulated noise-like signals, such as WiMAX, requires to use proper measurement methods and to carefully set many instrument parameters to obtain reliable measurement results, otherwise a significant underestimate or overestimate of the human exposure can be obtained.

In this framework, this paper investigates the feasibility of using the traditional spectrum analyzer to perform the electromagnetic pollution measurements due to WiMAX devices. A large experimental campaign is carried out to identify the most proper measurement method and spectrum analyzer settings able to warrant reliable measurements.

Go to article

Authors and Affiliations

Giovanni Betta
Domenico Capriglione
Gianfranco Miele
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a method of measuring the angle of rotation and twist using a tilted fibre Bragg grating

(TFBG) periodic structure with a tilt angle of 6◦, written into a single-mode optical fibre. It has been shown

that the rotation of the sensor by 180◦ causes a change in the transmission coefficient from 0.5 to 0.84 at

a wavelength of 1541.2 nm. As a result of measurements it was determined that the highest sensitivity can

be obtained for angles from 30◦ to 70◦ in relation to the basic orientation. The change in the transmission

spectrum occurs for cladding modes that change their intensity with the change in the polarization of light

propagating through the grating. The same structure can also be used to measure the twist angle. The

possibility of obtaining a TFBG twist by 200◦ over a length of 10 mm has been proved. This makes it

possible to monitor both the angle of rotation and the twist of an optical fibre with the fabricated TFBG.

Go to article

Authors and Affiliations

Sławomir Cięszczyk
Piotr Kisała
Krzysztof Skorupski
Patryk Panas
Jacek Klimek
Download PDF Download RIS Download Bibtex

Abstract

In the paper an example of application of the Kalman filtering in the navigation process of automatically guided vehicles was presented. The basis for determining the position of automatically guided vehicles is odometry – the navigation calculation. This method of determining the position of a vehicle is affected by many errors. In order to eliminate these errors, in modern vehicles additional systems to increase accuracy in determining the position of a vehicle are used. In the latest navigation systems during route and position adjustments the probabilistic methods are used. The most frequently applied are Kalman filters.
Go to article

Authors and Affiliations

Mirosław Śmieszek
Magdalena Dobrzańska
Download PDF Download RIS Download Bibtex

Abstract

An innovative system designed for the continuous monitoring of acoustic climate of urban areas was presented in the paper. The assessment of environmental threats is performed using online data, acquired through a grid of engineered monitoring stations collecting comprehensive information about the acoustic climate of urban areas. The grid of proposed devices provides valuable data for the purpose of long and short time acoustic climate analysis. Dynamic estimation of noise source parameters and real measurement results of emission data are utilized to create dynamic noise maps accessible to the general public. This operation is performed through the noise source prediction employing a propagation model being optimized for computer cluster implementation requirements. It enables the system to generate noise maps in a reasonable time and to publish regularly map updates in the Internet. Moreover, the functionality of the system was extended with new techniques for assessing noise-induced harmful effects on the human hearing system. The principle of operation of the dosimeter is based on a modified psychoacoustic model of hearing and on the results of research performed with participation of volunteers concerning the impact of noise on hearing. The primary function of the dosimeter is to estimate, in real time, auditory effects which are caused by exposure to noise. The results of measurements and simulations performed by the system prototype are depicted and analyzed. Several cases of long-term and short-term measurements of noise originating from various sources were considered in detail. The presented outcomes of predicted degree of the hearing threshold shift induced during the noise exposure can increase the awareness of harmfulness of excessive sound levels.

Go to article

Authors and Affiliations

Bożena Kostek
Andrzej Czyżewski
Józef Kotus
Maciej Szczodrak
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a method of measuring deformations of cylindrical samples on the testing machine for free tube hydroforming experiments. During experiments a sample made of a thin-walled metal tube is expanded by the internal pressure of the working liquid and additionally subjected to axial compression. This results in a considerable circumferential deformation of the tube and its shortening. Analysis of the load cases and their impact on the deformations can be helpful in determining e.g. tube material properties or general limiting conditions in the tube hydroforming process. In connection with the above, the value of deformations and knowledge of their course during experiment has become one of the most important problems related to the issue described above.

Go to article

Authors and Affiliations

H. Sadłowska
Ł. Morawiński
C. Jasiński
Download PDF Download RIS Download Bibtex

Abstract

The paper presents improvements of the developed system for hot plasma radiation measurement in the soft Xray range based on a Gas Electron Multiplier (GEM) detector. Scope of work consists of a new solution for handling hardware time-synchronization with tokamak systems needed for better synchronization with other diagnostics and measurement quality. The paper describes the support of new modes of triggering on PC-side. There are communication and data path overview in the system. The new API is described, which provide separate channels for data and control and is more robust than the earlier solution. Work concentrates on stability and usability improvements of the implemented device providing better usage for end-user.
Go to article

Authors and Affiliations

Paweł Linczuk
1
Andrzej Wojenski
2
Piotr Kolasinski
2
Rafał Krawczyk
2 3
Wojciech Zabolotny
2
Krzysztof Pozniak
2
Maryna Chernyshova
4
Tomasz Czarski
4
Michał Gaska
2
Grzegorz Kasprowicz
2
Karol Malinowski
4

  1. Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  2. Institute of Electronic Systems, Faculty of Electronics and Information Technology, University of Technology, Warsaw, Poland
  3. CERN, Geneva, Switzerland
  4. Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland
Download PDF Download RIS Download Bibtex

Abstract

Robotic total stations are a group of surveying instruments that can be used to measure moving prisms. These devices can generate significant errors during kinematic surveys. This is due to the different speeds of the total station’s measurement subsystems, which results in the observations of the point location being performed in different places of the space. Total stations which are several years old may generate errors of up to a few dozen centimeters. More modern designs, with much lower delays of the mechanical and electronic subsystems, theoretically allow to significantly reduce the values of the errors. This study involved the performance of kinematic tests on the modern robotic total station Leica MS50 in order to determine the values of measurement errors, and also to define the possibility of using them for the above-mentioned applications.

Go to article

Authors and Affiliations

G. Lenda
A. Uznański
M. Strach
Download PDF Download RIS Download Bibtex

Abstract

It was demonstrated that in the fishes of the species Trematomus bernacchi, predominant in the regions of the USSR Antarctic Station Mirny (Davis Sea), body proportions changes along with the growth of these specimens. Measurements include 20 plastic features in 171 fishess (total length 110.2—265.0 mm). Statistically significant variations of eleven proportions of the body were stated during the growth of the fishes. Five other proportions changed in a degree of little statistical significance, whereas the last three of the body proportions did not change at all.

Go to article

Authors and Affiliations

Ryszard J. Wróblewski
Download PDF Download RIS Download Bibtex

Abstract

The results and method of measurements of D, H and T carried out at Hornsund in the summer of 1979 are presented. The relative and absolute values of these elements are given in reduction to the Polish magnetic station at Hornsund. An initial evaluation of changes in the magnetic field from 1957 to 1979 is carried out.

Go to article

Authors and Affiliations

Andrzej Koblański
Stanisław Małoszewski
Janusz Śliz
Download PDF Download RIS Download Bibtex

Abstract

This paper presents the results of magnetic mapping carried out in the area of the metamorphic series of Ariekammen and Skoddefjellet. On the basis of qualitative interpretation of measurements a number of anomalous zones were distinguished, whose position can be correlated with local changes in mineralitation and polymetallic ore content in the Fuglebergsletta area. The SE-NW orientation, skew to the almost meridional run of the layers of slates and marbles making up the metamorphic complex, dominates in the course of the anomalous zones.

Go to article

Authors and Affiliations

Andrzej Koblański
Download PDF Download RIS Download Bibtex

Abstract

Before disassemble and demolition of five granulation towers the authors planned and carried out measurements of the intensity of vibrations induced during the fall of the dismantled components of towers on the ground. The main aim of the study was to determine the maximum permissible weight of falling elements of the towers during the demolition, in terms of ensuring the protection of buildings and equipment located in the vicinity of the works. It was unacceptable to increase the vibration amplitude displacement in each section of measurement on each of the three perpendicular axes by more than 2 μm peak-to-peak value and the absolute velocity of RMS of vibration amplitude couldn’t be increased by more than 1 mm/sec value than the background vibration during the demolition of the towers. Preliminary experimental studies were conducted on a test stand and the measurements were made on the real object. The amplitudes of vibration waves displacement and velocity were recorded on the measurement section in the direction of the protected building. The results of measurements were used to identify the propagation of the shock wave and the effectiveness of the proposed insulation layers.

Go to article

Authors and Affiliations

Jan Targosz
Jarosław Bednarz
Wojciech Lisowski
Download PDF Download RIS Download Bibtex

Abstract

The aim of this paper is two-fold. First, some basic notions on acoustic field intensity and its measurement are shortly recalled. Then, the equipment and the measurement procedure used in the sound intensity in the performed research study are described. The second goal is to present details of the design of the engineered 3D intensity probe, as well as the algorithms developed and applied for that purpose. Results of the intensity probe measurements along with the calibration procedure are then contained and discussed. Comparison between the engineered and the reference commercial probe confirms that the designed construction is applicable to the sound field intensity measurements with a sufficient effectiveness.

Go to article

Authors and Affiliations

Bożena Kostek
Andrzej Czyżewski
Józef Kotus
Download PDF Download RIS Download Bibtex

Abstract

Many precision devices, especially measuring devices, must maintain their technical parameters in variable ambient conditions, particularly at varying temperatures. Examples of such devices may be super precise balances that must keep stability and accuracy of the readings in varying ambient temperatures. Due to that fact, there is a problem of measuring the impact of temperature changes, mainly on geometrical dimensions of fundamental constructional elements of these devices. In the paper a new system for measuring micro-displacements of chosen points of a constructional element of balance with a resolution of single nanometres and accuracy at a level of fractions of micrometres has been proposed.

Go to article

Authors and Affiliations

Marek Dobosz
Adam Woźniak
Mariusz Kożuchowski
Marek Ściuba
Olga Iwasińska-Kowalska
Download PDF Download RIS Download Bibtex

Abstract

The article presents an application of Prony’s method with some known components in the analysis of electric power quality. Modifications of the Prony algorithm broaden the scope of method application. Modification of the filter of known components enables more accurate analysis of the parameters of unknown components and components with known or assumed frequencies. This article presents a comparison of the results of analyses conducted with the proposed algorithm for simulated and real signals and the results obtained by means of a commercial electric power quality testing device, operating in class A and using the Fourier transform. The proposed method enables to estimate the levels of the harmonic components, the frequency of the fundamental signal and real parameters of the interharmonic components, which are grouped and averaged in the contemporary monitoring equipment. Knowledge of the individual parameters of the interharmonics has considerable diagnostic importance while removing causes of incorrect operation affecting sensitive equipment in some electric power systems. Additionally, the algorithm is capable of analyzing exponentially damped components and finds its application in analysis of disturbances, for example, transient oscillations.

Go to article

Authors and Affiliations

Janusz Mroczka
Jarosław Zygarlicki
Download PDF Download RIS Download Bibtex

Abstract

The aim of this paper is the methodology of measurements executed in a radio link for the realization of radiolocation services in radiocommunication networks, particularly in cellular networks. The main results of the measurements obtained in the physical layer of the universal mobile telecommunications system (UMTS) are introduced. A new method for the utilization of the multipath propagation phenomenon to improve the estimation of the distance between the mobile station (MS) and the base station (BS) is outlined. This method significantly increases the quality of location services in systems which use a radio interface with direct sequence code division multiple access (DS CDMA).

Go to article

Authors and Affiliations

Jacek Stefanski
Download PDF Download RIS Download Bibtex

Abstract

In the paper selected methods of measuring the thermal resistance of an IGBT (Insulated Gate Bipolar Transistor) are presented and the accuracy of these methods is analysed. The analysis of the measurement error is performed and operating conditions of the considered device, at which each measurement method assures the least measuring error, are pointed out. Theoretical considerations are illustrated with some results of measurements and calculations.
Go to article

Authors and Affiliations

Krzysztof Górecki
Paweł Górecki
Download PDF Download RIS Download Bibtex

Abstract

Investigations of operating parameters of widely used sand mixers reveal a wide variability range in the values of parameters associated

with their power demand. Power efficiency of manufacturing processes has received a great deal of attention lately, which encourages the

research efforts to optimise this aspects of operation of machines and installations as well. In the first place these machines

and installations have to work properly as a part of the process line- which applies also to moulding sand mixers. Experiments conducted

by the authors suggest that the same goal can be achieved at variable energy input levels. To obtain information about the power demands

of sand mixers requires the use of highly specialised equipment, methodology and result processing procedures. This study provides a brief

characteristic of measurement equipment and results of measurements taken on a unit AG-015 (based on a roller mixer) and a laboratory

rotor mixer.

Go to article

Authors and Affiliations

K. Smyksy
E. Ziółkowski
R. Wrona
Download PDF Download RIS Download Bibtex

Abstract

This paper presents an example of practical use of Prony's method for monitoring of power waveform fundamental harmonic fluctuations, which is required for the analysis of window synchronizations in frequency analyses in power monitoring systems. The example presented offers verification of the authors' theoretical considerations published earlier in articles about Prony's method and its opportunities for practical use for real life signals. The investigations shown are based on the least squares Prony's method, which, in connection with digital filtrations, enables estimations of fundamental frequency at the rate of even tens of times per one fundamental harmonic period.

Go to article

Authors and Affiliations

Janusz Mroczka
Jarosław Zygarlicki
Download PDF Download RIS Download Bibtex

Abstract

The article presents a new modification of the the least squares Prony method. The so-called variable-frequency Prony method can be a useful tool for estimating parameters of sinusoidal components, which, in the analyzed signal, are characterized by time-dependent frequencies. The authors propose use of the presented method for testing the quality of electric energy. It allows observation of phenomena which, when using traditional methods, are averaged in the analysis window. The proposed modification of least squares Prony method is based on introduction and specific selection of a frequency matrix. This matrix represents frequencies of estimated components and their variability in time.

Go to article

Authors and Affiliations

Janusz Mroczka
Jarosław Zygarlicki
Download PDF Download RIS Download Bibtex

Abstract

This article presents a way of analyzing the transfer function of electronic signal amplifiers. It also describes the possibility of using signal precorrection which improves the parasitic harmonics in the THD (Total Harmonic Distortion) of the amplified signal by correcting linearity of the tested amplifier’s transfer function. The proposed method of analyzing and presenting the transfer function allows to diagnose the causes of generating parasitic harmonics, what makes it a useful tool when designing low distortion amplifier systems, such as e.g. amplifiers in measurement systems. The presented THD correction can be used in e.g. amplifier systems that cooperate with arbitrary generators.

Go to article

Authors and Affiliations

Janusz Mroczka
Jarosław Zygarlicki
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a method of adaptation of the original second order Prony’s method for applications in lowcost digital measurement systems with low computing performance. The presented method can be used in measuring systems where it is important to obtain in real time the values of amplitude, frequency, initial phase and damping coefficient of a single sinusoidal component of an analysed signal. The paper presents optimized, in terms of the number of mathematical operations, implementation of the method in selected embedded devices as well as the calculation times of the method for each platform.

Go to article

Authors and Affiliations

Jarosław Zygarlicki
Download PDF Download RIS Download Bibtex

Abstract

In the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and a resistive sensor connected in parallel with an interference suppression capacitor. The measurement method is based on stimulation of the sensor interface circuit by a single square voltage pulse and on sampling the resulting voltage on the resistive sensor. The proposed solution is illustrated by a complete application of the compact smart resistive sensor used for temperature measurements, based on an 8-bit ATxmega32A4 microcontroller with a 12-bit ADC and a Pt100 resistive sensor. The results of experimental research confirm that the compact smart resistive sensor has 1°C resolution of temperature measurement for the whole range of changes of measured temperatures.

Go to article

Authors and Affiliations

Zbigniew Czaja

This page uses 'cookies'. Learn more