Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 5
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Inguinal hernia repairs are one of the most common procedures performed in general surgical departments. Approximately 20 million hernia repairs are performed annually all over the world. According to the EHS guidelines, the recommended treatment methods of the inguinal hernia are tension–free techniques: the Lichtenstein open hernia repair and the laparoscopic transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) methods. The TEP hernia repair, first performed by Duluq in 1992, is one of the three current leading techniques in the inguinal hernia repair. The most important advantage of this technique is minimal invasive access without the need to open the peritoneum, which carries a lower risk of abdominal organs injury. Additionally, the TEP method facilitates shorter recovery time, less postoperative pain and an earlier discharge form hospital. The aim of the article is to present the TEP method by comparing it with the other inguinal hernia repair techniques, on the basis of the available literature.

Go to article

Authors and Affiliations

Jakub Łomnicki
Agnieszka Leszko
Daria Kuliś
Mirosław Szura
Download PDF Download RIS Download Bibtex

Abstract

The aim of the study was to develop a method of laparoscopic embryo transfer in pigs and to compare different variants of this method. Two catheter diameters (1.6 mm and 1.0 mm), the method and site of embryo deposition (oviduct or uterus), the embryo development stage (2 – 4 cell or blastocyst), the method for oviduct or uterus stabilization, the potential for cryopreserved embryo transfer, the developmental potential of the embryos after transfer to the oviduct, patomorphology of the oviduct after transfer and possible clinical complications were taken into consideration. Two studies compared two variants of transfer to the uterus, and five variants of transfer to the fallopian tube. The transfer of embryos by the infundibulum may be of limited use due to handling problems and very low efficiency (pregnancy was not achieved). Very low efficiency was shown after transfer of vitrified embryos. Transfer to the fallopian tube by puncture of the fallopian tube, regardless of the developmental stage of the embryo, is the recommended method of embryo transfer. The histopathological examination of the fallopian tube revealed possible changes within the puncture site. The numerous clinical complications observed did not affect the effectiveness of the method.
Go to article

Authors and Affiliations

J. Wieczorek
1
E. Stodolak-Zych
2
ORCID: ORCID
K. Okoń
3
J. Koseniuk
4
M. Bryła
5
J. Jura
5
K. Poniedziałek-Kempny
5
I. Rajska
5
K. Sobol
5
M. Kotula Balak
1
M. Chmurska-Gasowska
1

  1. University Centre of Veterinary Medicine, University of Agriculture in Krakow, Mickiewicza 24/28, 30-059 Krakow, Poland
  2. Department of Biomaterials, Faculty of Materials Science and Ceramics, University of Science and Technology, Mickiewicza 30, 30-059 Krakow, Poland
  3. Chair of Pathomorphology, Collegium Medicum, Jagiellonian University, Grzegorzecka 16, 30-526 Krakow, Poland
  4. Artvimed Centre for Reproductive Medicine, Czyzowka 14, 30-526 Krakow, Poland
  5. Department of Reproductive Biotechnology and Cryoconservation, National Research Institute of Animal Production, Krakowska 1, 30-322 Balice/Krakow, Poland
Download PDF Download RIS Download Bibtex

Abstract

The aim of the study was to develop new laparoscopic technique for repeated recovery of sheep oocytes. Oocytes were aspirated with specifically designed catheter. It allowed to recover oocytes without ovary damage and to preserve very good quality of recovered oocytes. Fifteen ewes were oocytes donors. Oocytes were collected: one time (group I, n=15), two times (group II, n=15), three times (group III, n=10), four times (group IV, n=5). The endoscope was inserted into the abdominal cavity. Two trockars for putting the manipulators were inserted 15 cm cranial from the udder. Oocytes were collected by aspiration of the follicular fluid from the ovarian follicles. The observed clinical complications were: ovary bleeding and cicatrix at place of needle insertion, the fragmentary adhesion of infundibulum and ovary, adhesions of omentum and peri- toneum near the place where the grasping forceps were inserted and adhesion of ovary and uterus. Ovarian follicles (n=204) were aspirated, 130 (63.8%) oocytes were obtained. Out of 130 obtained oocytes, 112 were qualified for in vitro maturation. The remaining 18 oocytes (13.8%) were rejected due to cytoplasmic changes. The proposed technique allows for the collecting oocytes of good quality that can be used for IMV/IVF techniques and cloning.

Go to article

Authors and Affiliations

J. Wieczorek
J. Koseniuk
M. Cegla
Download PDF Download RIS Download Bibtex

Abstract

Conventional methods for determining the reproductive performance of sheep bred either after estrus synchronization during the breeding season or after induction of estrus/ovulation during the non-breeding season take a long time and may give misleading results due to the effect of environmental factors. Laparoscopic observations allow real-time monitoring of ovarian activity around estrus or ovulation. This study was aimed at assessing the superovulatory effects of follicle-stimulating hormone (FSH) and equine chorionic gonadotropin (eCG) treatments by laparoscopy during breeding (September-November, n=12) and non-breeding (April-June, n=12) seasons in Akkaraman sheep. In both seasons, after CIDR withdrawal, the ewes were injected either with 600 IU eCG or 300 μl (20 mg/ml) FSH twice at 12 hour intervals. Plasma P4, E2 and LH concentrations were determined at the time of intra-vaginal CIDR insertion (day 0) and then at its withdrawal (day 12), followed by 3 and 6 days of eCG or FSH injections. After 3 (first observation) and 6 (second observation) days of hormone injections, laparoscopy was performed to record ovarian activity in both seasons. The eCG increased (p<0.05) the numbers of large follicles (first observation) and CL (first and second observations) in the breeding season compared to FSH treatment. CL, small-moderate and large follicle numbers of eCG treated ewes were higher (p<0.05) than those of FSH at both observations in the non-breeding season. In the breeding season, eCG treated ewes had higher (p<0.05) plasma P4 (3 and 6 days after hormones injections) and E2 (3 days after hormones injections) concentrations than those of FSH. In conclusion, the results of the present study indicate that treatment with eCG during the non-breeding season can support ovarian activity, and thus increase ovulation rate and plasma hormone concentrations around induced estrus/ovulation in Akkaraman ewes.

Go to article

Authors and Affiliations

U. Şen
Download PDF Download RIS Download Bibtex

Abstract

Whatever the type of surgery related to inner organs, traditional or robotic, the contact with them during surgery is a key moment for pursuing the intervention. Contacts by means of surgery instruments namely scalpels, staples, clamps, graspers, etc. are decisive moments. False, and erroneous touching and manoeuvring of organs operated on can cause irreversible damage as regard morphological aspects (outer impact) and physiological aspects (inner impact). The topic is a great challenge in the effort to measure and characterize damages. In general, electrical instruments for surgery employ the following technologies: ultrasound, radiofrequency (monopolar, and bipolar), and laser. They all result in thermal damages difficult to evaluate. The article proposes a method for a pre-screening of organ features during robotic surgery sessions by pointing out mechanical and thermal stresses. A dedicated modelling has been developed based on experimental activities during surgery session. The idea is to model tissue behaviour from real images to help surgeons to be aware of handling during surgery. This is the first step for generalization by considering the type of organ. The measurement acquisitions have been performed by means of an advanced external camera located over the surgery quadrant. The modelling and testing have been carried out on kidneys. The modelling, carried out through Comsol Multiphysics, is based on the bioheat approach. A further comparative technique has been implemented. It is based on computer vision for robotics. The findings of human tissue behavior exhibit reliable results.
Go to article

Authors and Affiliations

Aimé Lay-Ekuakille
1
Moise Avoci Ugwiri
2
Consolatina Liguori
2
Satya P. Singh
3
Md Zia Uhr Rahman
4
Domenico Veneziano
5

  1. University of Salento, Department of Innovation Engineering, Via Monteroni sn, 73100 Lecce, Italy
  2. University of Salerno, Department of Industrial Engineering, Via Giovanni Paolo II n.132, 84084 Fisciano, Italy
  3. Nanyang Technological University, School of Computer Science and Engineering, 50 Nangyang Ave, Singapore 639798
  4. K L University, Department of Electronics & Communication Engineering, Green Fields, Vaddeswaram, Guntur-522502, India
  5. Asl Reggio Calabria, Hospital “Bianchi-Melacrino-Morelli”, Via Giuseppe Melacrino n.21, 89124 Reggio Calabria, Italy

This page uses 'cookies'. Learn more