Search results

Filters

  • Journals
  • Autorzy
  • Słowa kluczowe
  • Data
  • Typ

Search results

Number of results: 17
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Many techniques of soil bioremediation enhancement have been developed recently. Two of them are application of weak electric field which induces favorable electrokinetic phenomena in the soil environment and surface active agents application which increase the biodegradation degree of poorly soluble contamination. During experiments the influence of the electric field and surfactants (biosurfactants, non-ionic and anionic surfactants) on the Pseudomonas putida and Bacillus subtilis bacteria migration in soil was determined. The intensity of the biodegradation of contamination was also estimated. The results show substantial impact of the electric field and surfactants on the intensity and direction of bacteria migration in soil as well as on the intensity of the contamination biodegradation.
Go to article

Authors and Affiliations

Krzysztof Piechowiak
Andrzej Olszanowski
Download PDF Download RIS Download Bibtex

Abstract

Complex gaps may be formed when carrying out live working in substations, while the discharge characteristics of complex gaps are different from those of single gaps. This paper focuses on the prediction of critical 50% positive switching impulse breakdown voltage ( U 50–crit + of phase-to-phase complex gaps formed in 220 kV substations. Firstly, several electric field features were defined on the shortest discharge path of the complex gap to reflect the electric field distribution. Then support vector machine (SVM) prediction models were established according to the connection between electric field distribution and breakdown voltage. Finally, the U 50–crit¸+ data of the complex gap were obtained through twice electric field calculations and predictions. The prediction results show that the minimum U 50–crit + of phase-to-phase complex gaps is 1147 kV, and the critical position is 0.9 m away from the high voltage conductor, accounting for 27% of the whole gap. Both critical position and voltage are in good agreement with the values provided in IEC 61472.
Go to article

Authors and Affiliations

Zhenpeng Tang
1
Yuancheng Qin
2
ORCID: ORCID
Changsheng Wu
1
Ronghuan Mai
1

  1. Jiangmen Power Supply Bureau Co., Ltd., China
  2. School of Automation, Wuhan University of Technology, China
Download PDF Download RIS Download Bibtex

Abstract

As a kind of mass transfer process as well as the basis of separating and purifying mixtures, interfacial adsorption has been widely applied to fields like chemical industry, medical industry and purification engineering in recent years. Influencing factors of interfacial adsorption, in addition to the traditional temperature, intensity of pressure, amount of substance and concentration, also include external fields, such as magnetic field, electric field and electromagnetic field, etc. Starting from the point of thermodynamics and taking the Gibbs adsorption as the model, the combination of energy axiom and the first law of thermodynamics was applied to boundary phase, and thus the theoretical expression for the volume of interface absorption under electric field as well as the mathematical relationship between surface tension and electric field intensity was obtained. In addition, according to the obtained theoretical expression, the volume of interface absorption of ethanol solution under different electric field intensities and concentrations was calculated. Moreover, the mechanism of interfacial adsorption was described from the perspective of thermodynamics and the influence of electric field on interfacial adsorption was explained reasonably, aiming to further discuss the influence of thermodynamic mechanism of interfacial adsorption on purifying air-conditioning engineering under intensification of electric field.

Go to article

Authors and Affiliations

Yun-Yu Chen
Download PDF Download RIS Download Bibtex

Abstract

The development of a distributed generation will influence the structure of the power transmission and distribution network. Distributed sources have lower power and therefore the lines of lower voltage are used. Therefore, the electric field intensity near such lines is lower. On the other hand magnetic field intensity may prove essential. The main aim of the paper is to present a method estimating the “ballast” of the natural environment at 50 Hz electric and magnetic fields in the power system, with distributed and centralized generation in real operating conditions.

Go to article

Authors and Affiliations

Michał Zeńczak
Download PDF Download RIS Download Bibtex

Abstract

In this work we discussed the safety of the electric field environment in the No.3 carriage where the pantograph is located. DSA380 pantograph, CRH5 EMU carriage and passengers’ models were established to study the electric field exposure of passengers at different positions. The results showed that Emax in the carriage without passengers is 1.173 x 10 6 mV/m. Then we set the passengers’ positions according to the electric field distribution in the carriage without passengers and obtained that Emax in the carriage with passengers is 3.195 x 10 6 mV/m. It can be seen that the maximum induced electric field intensity of passengers at different positions appears on the soles of shoes, the maximum value is 3.028 x 105 mV/m, the maximum induced current density occurs at the ankle, its maximum value is 3.476 x 10 -5 A/m 2. It can be concluded that the maximum induced electric field intensity of passenger’s head appears in the cerebrospinal fluid area, with a maximum value of 202.817 mV/m, and the maximum induced electric field intensity of passenger’s head at the door is larger than that in the middle of the carriage. The maximum values of the induced electric field intensity in all tissues of passengers are much smaller than the basic limits of electromagnetic exposure to the public set by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). This study indicated that the pantograph has little influence on the electric field environment in the carriage under working state, and will not cause any health hazard to the passengers in this working frequency electric field environment.
Go to article

Authors and Affiliations

Rui Tian
1
Jia-qi Zhang
1
Mai Lu
1
ORCID: ORCID

  1. Key Laboratory of Opto-Electronic Technology and Intelligent Control of Ministry of Education, Lanzhou Jiaotong University, Gansu Province, China
Download PDF Download RIS Download Bibtex

Abstract

The instability characteristics of a dielectric fluid layer heated from below under the influence of a uniform vertical alternating current (AC) electric field is analyzed for different types of electric potential (constant electric potential/ electric current), velocity (rigid/free) and temperature boundary conditions (constant temperature/heat flux or a mixed condition at the upper boundary). The resulting eigenvalue problem is solved numerically using the shooting method for various boundary conditions and the solution is also found in a simple closed form when the perturbation heat flux is zero at the boundaries. The possibility of a more precise control of electrothermal convection (ETC) through various boundary conditions is emphasized. The effect of increasing AC electric Rayleigh number is to hasten while that of Biot number is to delay the onset of ETC. The system is more stable for rigid-rigid boundaries when compared to rigid-free and least stable for free-free boundaries. The change of electric potential boundary condition at the upper boundary from constant electric potential to constant electric current is found to instill more stability on the system. Besides, increase in the AC electric Rayleigh number and the Biot number is to reduce the size of convection cells.

Go to article

Authors and Affiliations

M. Ravisha
K.R. Raghunatha
A.L. Mamatha
I.S. Shivakumara
Download PDF Download RIS Download Bibtex

Abstract

Analytical relations, describing the electrical fields of cylindrical piezoceramic radiators with circular polarization as a member of the cylindrical systems with the baffle in the inner cavity, using the related fields method in multiply connected regions were obtained. Comparative analysis of the results of numerical experiments performed on the frequency characteristics of the electric field of the radiating systems for different modes of radiation allow to establish a number of subtle effects of the formation of the electric field of radiators.

Go to article

Authors and Affiliations

Aleksandr Leiko
Anatolii Derepa
Aleksandr Rasstrygin
Andrii Kosiakovskyi
Oksana Kocharian
Yaroslav Starovoit
Download PDF Download RIS Download Bibtex

Abstract

In this work, an electrically tunable long-period fiber grating (LPFG) coated with liquid crystal layer (LC) is presented. As a LC layer, a prototype low-birefringence 1550A LC mixture was chosen. As a LPFG host, two types of gratings were studied: the LPFGs based on a standard telecommunication fiber, produced by an electric arc technique with a period of 222 μm, and the LPFGs based on a boron co-doped fiber written by a UV technique with a period of 226.8 μm. The relatively short period of these gratings allowed exploiting unique sensing properties of the attenuation bands associated with modes close to the turn-around point. Experiments carried out showed that for the UV-induced LPFG with a LC layer, on the powered state the attenuation band could be offset from the attenuation band measured in the unpowered state by almost 130 nm. When the arc-induced LPFG was coated with the LC, the depth of the attenuation band could be efficiently controlled by applying an external E-field. Additionally, all experimental results obtained in this work were supported by the theoretical analysis based on a model developed with Optigrating v.4.2 software.

Go to article

Authors and Affiliations

A. Czapla
W.J. Bock
T.R. Woliński
P. Mikulic
R. Dąbrowski
E. Nowinowski-Kruszelnicki
Download PDF Download RIS Download Bibtex

Abstract

Extremely dense fog event was studied on the 3rd December 2001, which occurred in the city of Apatity, the Kola Peninsula, northwestern Russia. Fog had low visibility (30–50 m) and lasted 17 h. Variations of atmospheric pressure and electric field before and during the fog event were measured. Multiple Taper Method (MTM) of spectral analysis has revealed pulsations of the atmospheric electric field in the frequency band of 0.007–0.05 Hz with a power-law turbulence spectrum. MTM and wavelet decomposition analysis results indicate the appearance of two types of atmospheric pressure oscillations under the fog conditions: low-frequency variations with periods of internal gravity waves and a substantial increase in pulsation intensity (more than an order of magnitude) in the high frequency (0.03–0.35 Hz) range. These results may help to improve the understanding of the microphysics of fog formation, development, and dissipation. High-frequency pulsations generation of atmospheric pressure under the fog conditions is also of interest because their period is close to the range of infrasonic oscillations, which can have negative consequences for human health.
Go to article

Authors and Affiliations

Oleg I. Shumilov
1
Elena A. Kasatkina
1
Dmitry V. Makarov
1
Marek Krapiec
2

  1. Institute of North Industrial Ecology Problems, Kola Science Centre RAS, Fersman 14a, Apatity, Russia
  2. University of Science and Technology (AGH), Mickiewicza 30, 30-059 Krakow, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper presents optimization of power line geometrical parameters aimed to reduce the intensity of the electric field and magnetic field intensity under an overhead power line with the use of a genetic algorithm (AG) and particle swarm optimization (PSO). The variation of charge distribution along the conductors as well as the sag of the overhead line and induced currents in earth wires were taken into account. The conductor sag was approximated by a chain curve. The charge simulation method (CSM) and the method of images were used in the simulations of an electric field, while a magnetic field were calculated using the Biot–Savart law. Sample calculations in a three-dimensional system were made for a 220 kV single – circuit power line. A comparison of the used optimization algorithms was made.

Go to article

Authors and Affiliations

Krzysztof Król
Wojciech Machczyński
Download PDF Download RIS Download Bibtex

Abstract

This paper describes multiple electric field control methods for foil coils in high-voltage coreless linear actuators and their sensitivity to misalignment. The investigated field control methods consist of resistive, refractive, capacitive and geometrical solutions for mitigating electric stress at edges and corners of foil coils. These field control methods are evaluated using 2-D boundary element and finite element methods. A comparison is presented between the field control methods and their ability to mitigate electric stress in coreless linear actuators. Furthermore, the sensitivity to misalignment of the field control methods is investigated.
Go to article

Authors and Affiliations

T.A. van Beek
J.W. Jansen
E.A. Lomonova
Download PDF Download RIS Download Bibtex

Abstract

The purpose of the presented research is to analyse possible methods of thickening of the Microcystis aeruginosa (Kützing) Kützing cyanobacteria using the obtained concentrate as a biomass for the production of energy carriers and bio-logically valuable substances. Method of cyanobacteria thickening under the action of electric current and in the electric field, as well as the method of coagulation–flocculation and gravity thickening, was experimentally investigated in lab-scale conditions. Electrical methods didn't show positive results for the Microcystis aeruginosa thickening, despite the re-ports of their potential efficiency in a number of previous studies. The high efficiency of the method of coagulation–flocculation and gravity thickening of Microcystis aeruginosa suspensions was obtained. The optimum concentrations of industrial polymeric coagulants and flocculants for the thickening of Microcystis aeruginosa suspensions were defined in the range of about 10 ppm for the coagulants and about 1 ppm for the flocculants. Negative effect of the previous cavitational treatment of the diluted suspensions of Microcystis aeruginosa on the effectiveness of the coagulation–flocculation and gravitational thickening was confirmed experimentally. Hydrodynamic cavitation should be recommended to use after the thickening as the next step of processing of concentrated suspensions of Microcystis aeruginosa to achieve maximum extraction of energy carriers and biologically valuable substances.

Go to article

Authors and Affiliations

Myroslav Malovanyy
Volodymyr Zhuk
Volodymyr Nykyforov
Igor Bordun
Iurii Balandiukh
Galyna Leskiv
Download PDF Download RIS Download Bibtex

Abstract

Food processing technologies for food preservation have been in constant development over a few decades in order to meet current consumer’s demands. Healthy competitive improvements are observed in both thermal and non-thermal food processing technology since past two decades due to technical revolution. Among these novel technologies, pulsed electric field food processing technology has shown to be a potential non-thermal treatment capable of preserving liquid foods. The high-voltage pulse generators specifically find their applications in pulsed electric field technology. So, this paper proposes a new structure of a high-voltage pulse generator with a cascaded boost converter topology. The choice of a cascaded boost converter helps in selecting low DC input voltage and hence the size and space requirement of the high-voltage pulse generator is minimized. The proposed circuit is capable of producing high-voltage pulses with flexibility of an adjusting duty ratio and frequency. The designed circuit generates a maximum peak voltage of 1 kV in the frequency range of 7.5–20 kHz and the pulse width range of 0.8–1.8 μs. Also, the impedance matching between the cascaded boost converter and the high-voltage pulse generator is found simple without further additional components. The efficiency can be improved in the circuit by avoiding low frequency transformers.
Go to article

Bibliography

[1] Nazni P., Shobana Devi R., Effect of Processing on the Characteristics Changes in Barnyard and Foxtail Millet, Journal of Food Processing Technology, vol. 7, no. 3, pp. 1–8 (2016).
[2] Khanam A., Platel K., Influence of domestic processing on the bioaccessibility of selenium from selected food grains and composite meals, Journal of Food Science and Technology, vol. 53, no. 3, pp. 1634–1639 (2016).
[3] Gabaza M., Shumoy H., Louwagie L., Muchuweti M., Vandamme P., Du Laing G., Raes K., Traditional fermentation and cooking of finger millet: Implications on mineral binders and subsequent bioaccessibility, Journal of Food Composition and Analysis, vol. 68, pp. 87–94 (2018).
[4] Sunil Neelash C., Jaivir S., Suresh C., Vipul C., Vikrant K., Non-thermal techniques: Application in food industries-A review, Journal of Pharmacognosy and Phytochemistry, vol. 7, no. 5, pp. 1507–1518 (2018).
[5] Nowosad K., Sujka M., Pankiewicz U., Kowalski R., The application of PEF technology in food processing and human nutrition, Journal of Food Science and Technology, vol. 58, pp. 397–411 (2020), DOI: 10.1007/s13197-020-04512-4.
[6] Rana Muhammad A., Xin-An Z., Zhong H., Amna S., Anees Ahmed K., Ubaid U.R., Muneeb K., Tariq M., Combined effects of pulsed electric field and ultrasound on bioactive compounds and microbial quality of grapefruit juice, Journal of Food Processing and Preservation, vol. 42, no. 2 (2018), DOI: 10.1111/jfpp.13507 (2018).
[7] Ramune B., Gianpiero P., Nerijus L., Saulius S., Pranas V., Giovanna F., Application of pulsed electric field in the production of juice and extraction of bioactive compounds from blueberry fruits and their by-products, Journal of Food Science and Technology, vol. 52, no. 9, pp. 5898–5905 (2015).
[8] Carbonell-Capella J.M., Buniowska M., Cortes C., Zulueta A., Frigola A., Esteve M.J., Influence of pulsed electric field processing on the quality of fruit juice beverages sweetened with Stevia rebaudiana, Food and Bioproducts Processing, vol. 101, pp. 214–222 (2017).
[9] Caminity I.M., Palgan I., Noci F., Arantxa Muñoz, Whyte P., Cronin D.A., Morgan D.J., Lyng J.G., The effect of pulsed electric fields (PEF) in combination with high intensity light pulses (HILP) on Escherichia coli inactivation and quality attributes in apple juice, Innovative Food Science and Emerging, vol. 12, no. 2, pp. 118–123 (2011).
[10] Morales-de la Pena M., Elez-Martinez P., Martin-Belloso O., Food Preservation by Pulsed Electric Fields: An Engineering Perspective, Food Engineering Reviews, vol. 3, pp. 94–107 (2011).
[11] Buckow R., Sieh N., Toepfl S., Pulsed electric field processing of orange juice: a review on microbial, enzymatic, nutritional and sensory quality and stability, Comprehensive Reviews in Food Science and Food safety, vol. 12, pp. 455–467 (2013).
[12] Toepfl S., Pulsed electric field food processing – Industrial equipment design and commercial applications, Stewart Postharvest Review, vol. 8, pp. 1–7 (2012).
[13] Valic B., Muriel Golzio, Mojca Pavlin, Anne Schatz, Cecile Faurie, Weaver J.C., Electroporation of Cells and Tissues, IEEE Transaction on Plasma Science, vol. 28, pp. 24–33 (2000).
[14] Toepfl S., Heinz V., Knorr D., High intensity pulsed electric fields applied for food preservation, Chemical Engineering and Processing, vol. 46, pp. 537–546 (2007).
[15] Geveke D.J., Kozempel M., Scullen O.J., Brunkhorst C., Radio frequency energy effects on microorganisms in foods, Innovative Food Science and Emerging Technology, vol. 3, no. 2, pp. 133–138 (2002).
[16] Geveke D.J., Brunkhorst C., Inactivation of Escherichia coli in apple juice by radio frequency electric fields, Journal of Food Science, vol. 69, pp. 134–138 (2004).
[17] Geveke D.J., Brunkhorst C., Fan X., Radio frequency electric fields processing of orange juice, Innovative Food Science and Emerging Technologies, vol. 8, pp. 549–554 (2007).
[18] Krishnaveni S., Rajini V., Diode clamped gate driver-based high voltage pulse generator for electroporation, Turkish Journal of Electrical Engineering and Computer Sciences, vol. 26, pp. 2374–2384 (2018).
[19] Pokryvailo A., Yankelevich Y., Shapira M., A compact source of sub gigawatt sub-nanosecond pulses, IEEE Transaction on Plasma Science, vol. 32, pp. 1909–1918 (2004).
[20] Wu Y., Liu K., Qiu J., X., Xiao H., Repetitive and high voltage Marx generator using solid-state devices, IEEE Transaction on Dielectrics and Electrical Insulation, vol. 14, pp. 937–940 (2007).
[21] Ramya R., Raja P.R., Gowrisree V., High Voltage Pulsed Electric Field Application Using Titanium Electrodes for Bacterial Inactivation in Unpurified Water, Japan Journal of Food Engineering, vol. 20, no. 2, pp. 63–70 (2019).
[22] KasriN.N.F., Piah M.A.M., Adzis Z., Compact High-Voltage Pulse Generator for Pulsed Electric Field Applications: Lab-Scale Development, Journal of Electrical and Computer Engineering, vol. 2020, art. ID 6525483, pp. 1–12 (2020), DOI: 10.1155/2020/6525483.
[23] Flisara K., Meglica S.H., Morelj J., Golobb J., Miklavcic D., Testing a prototype pulse generator for a continuous flow system and its use for E. coli inactivation and microalgae lipid extraction, Bioelectochemistry, vol. 100, pp. 44–51 (2014).
[24] Merensky L.M., Kardo-Sysoev A., Shmilovitz D., Kesar A.S., Efficiency Study of a 2.2 kV, 1 ns, 1 MHz Pulsed Power Generator Based on a Drift-Step-Recovery Diode, IEEE Transactions on Plasma Science, vol. 41, no. 11, pp. 3138–3142 (2013).
[25] Zhang Y., Liu J., Cheng X., Zhang H., Bai G., A Way for High-Voltage μs-Range Square Pulse Generation, IEEE Transactions on Plasma Science, vol. 39, no. 4, pp. 1125–1130 (2011).
[26] Merla C., Amari S.E., Kenaan M., Liberti M., Apollonio F., Arnaud-Cormos D., Couder V., A 10- High-Voltage Nanosecond Pulse Generator, IEEE Transactions on Microwave Theory and Techniques, vol. 58, no. 12, pp. 4079–4085 (2010).
[27] Ndtoungou A., Hamadi A., Missanda A., Al-Haddad K., Modeling and control of a cascaded Boost Converter for a Battery Electric Vehicle, IEEE Electrical Power and Energy Conference, London, ON, Canada, pp. 182–187 (2012).
[28] Stala R., Pirog S., DC–DC boost converter with high voltage gain and a low number of switches in multisection switched capacitor topology, Archives of Electrical Engineering, vol. 67, no. 3, pp. 617–627 (2018), DOI: 10.24425/123667.
[29] Chen Z., Yong W., Gao W., PI and Sliding Mode Control of a Multi-Input-Multi-Output Boost-Boost Converter, WSEAS Transactions on Power Systems, vol. 9, pp. 87–102 (2014).
[30] Sira-Ramirez H., Silva-Origoza R., Control design techniques in power electronics devices, Springer (2006).
[31] Aamir M., Shinwari M.Y., Design, implementation and experimental analysis of two-stage boost converter for grid connected photovoltaic system, 3rd IEEE International Conference on Computer Science and Information Technology, Chengdu, China, pp. 194–199 (2010).
[32] Park S., Choi S., Soft-switched CCM boost converters with high voltage gain for high power applications, IEEE Transaction on Power Electronics, vol. 25, no. 5, pp. 1211–1217 (2010).
[33] Silveira G.C., Tofoli F.L., Bezerra L.D.S., Torrico-Bascope R.P., A nonisolated DC-DC boost converter with high voltage gain and balanced output voltage, IEEE Transaction on Industrial Electronics, vol. 61, no. 12, pp. 6739–6746 (2014).
[34] Sanders J.M., Kuthi A., Wu., Y.H., Vernier P.T., Gundersen M.A., A linear, single-stage, nanosecond pulse generator for delivering intense electric fields to biological loads, IEEE Transactions on Dielectrics and Electrical Insulation, vol. 16, no. 4, pp. 1048–1054 (2009).


Go to article

Authors and Affiliations

S. Krishnaveni
1
ORCID: ORCID
V. Rajini
1

  1. Sri Sivasubramaniya Nadar College of Engineering, India
Download PDF Download RIS Download Bibtex

Abstract

Due to rapid development of wireless systems and future implementation of the 5G system, it is necessary to increase number of the stations and/or number of radio emissions in current and new mobile service frequency bands. For each of the new or modified radio installation in Poland the Electromagnetic Field (EMF) strength levels has to be evaluated and measured/validated in accordance with allowable limits. In the paper the model of estimation of total EMF levels coming from mobile base stations radio emissions to be used for estimation of the whole country territory EMF levels is proposed. Results of preliminary analysis were also shown on practical examples. The model presented in the paper can be used for initial finding of possible places where exist the risk of exceedance of the maximum exposure limits and for analysis of potential radio network development taking into account current regulatory limits. The model will be used in computerized system SI2PEM which is developing in Poland for EMF levels controlling and validation purposes.

Go to article

Authors and Affiliations

Dariusz Więcek
Daniel Niewiadomski
Marcin Mora
Download PDF Download RIS Download Bibtex

Abstract

A comparative analysis of filtration performance of tangential and axial inlet reverse-flow cyclone separators and vortex tube separators is presented. The study showed that vortex tube separators are characterized by a quality factor q several time higher than tangential inlet reverse-flow cyclone separators. The cyclone separators yield low separation efficiency and low filtration performance at low air flow rates at low air volumes aspired by the engine at low speed. One of the well-known and not commonly used methods to improve separation efficiency is to apply electric field. An original design of a vortex tube separator with insulators generating electric field in the area of aerosol flow is presented. High voltage was applied to the cyclone separator housing and its swirl vane. A special method and test conditions were developed for cyclone separators with electric field. Separation efficiency, filtration performance and pressure drop across the cyclone separator in two different variants were determined. The tests were carried out at five inlet velocity of cyclones υ0  = 1.75; 3.5; 7.0; 10.5; 14 m/s at an extraction rate of m0  = 10%, and at an average dust concentration in the inlet air of
s = 1 g/m3. Using the electric field in the area of a swirling aerosol stream resulted in an increase (over 12% – φc  = 96.3%) in separation efficiency at inlet velocity of cyclone ranging from 1.75 to 3.5 m/s. An increase in separation efficiency at other inlet velocity of cyclone is minor and does not exceed 3‒4%.

Go to article

Authors and Affiliations

T. Dziubak
Download PDF Download RIS Download Bibtex

Abstract

Studies aimed at the economically sound increase in the capacity of existing power lines and improvements in their design are relevant today. In addition to the well-known design methods of influencing the capacity of the transmission line, there are other meanings that can affect its natural capacity, which is directly related to the capacity. Therefore, the purpose of this study was to find possible methods of increasing natural power and evaluate their effectiveness in real configurations. The basis of the methodological approach applied in this study is a qualitative combination of methods of systematic analysis of ways to increase the capacity of power lines with the analytical investigation of the prospects for its impact on wave resistance to increase the natural power of the line. The conducted research determined the total influence of the analyzed factors on the increase in transmission capacity and identified the most optimal configuration from a technical and economic standpoint. Based on the results of the calculation of the natural capacity of the configurations, conclusions were made about the significance of the impact of each of the above factors, and the economic effect of their implementation in the integrated power system was established. Improvement of this methodology can, in the long run, serve as a tool for calculating configurations for economic and technical relevance, or serve as a foundation for further identification of factors affecting the transmission capacity of power lines.
Go to article

Authors and Affiliations

Nataliya Komenda
1
ORCID: ORCID
Vladyslav Volynets
1
ORCID: ORCID
Iryna Hrytsiuk
1
ORCID: ORCID
Irina Bandura
1
ORCID: ORCID
Mykola Romaniuk
1
ORCID: ORCID

  1. Department of Electrical Engineering, Lutsk National Technical University, Lutsk, Ukraine
Download PDF Download RIS Download Bibtex

Abstract

To evaluate the occupational safety of a high signal operator exposed to the electric field induced by contact wires with a frequency of 50 Hz and a voltage of 27.5 kV, this study established a model of a high signal operator working in the vicinity of singleand double-track railways. The electric field distribution in the operator’s body and his head were calculated and analyzed during the operation using the finite element method (FEM). The calculated results were compared with the international standard occupational exposure limits formulated by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and action levels (ALs), exposure limit values (ELVs) in Directive 2013/35/EU (EU Directive). In the case of a single-track railway exposure, the maximum electric field strength in the worker’s body, in the scalp layer, and inside the brain are 227 mV/m, 2.76 kV/m, and 0.14 mV/m, respectively. For a double-track railway exposure, the maximum internal electric field strength of the operator is 310 mV/m, which is 37.85% of the occupational exposure basic restriction limit. The maximum electric field strength in the head layers is 3.42 kV/m, which is 34.2% of the occupational exposure reference level and 34.2% of the low ALs. The maximum electric field strength of the brain is 0.19 mV/m, which is 0.19% of the occupational basic restriction limit and 0.135% of the sensory effects ELVs. Results show that the electric field exposure of the high signal operator to contact wires in single- and double-track railways is lower than the occupational exposure limits provided by the ICNIRP and EU Directive standards and is thus regarded as safe forworkers.
Go to article

Bibliography

[1] Wyszkowska J.W., Jankowska M., Gas P., Electromagnetic fields and neurodegenerative diseases, Przeglad Elektrotechniczny, vol. 95, no. 1, pp. 129–133 (2019).
[2] Mahaki H., Jabarivasal N., Sardarian K., Zamani A., Effects of various densities of 50 Hz electromagnetic field on serum IL-9, IL-10, and TNF-α levels, The International Journal of Occupational and Environmental Medicine, vol. 11, no. 1, pp. 24–32 (2020).
[3] WertheimerN., Leeper E.D., Electrical wiring configurations and childhood cancer, American Journal of Epidemiology, vol. 109, no. 3, pp. 273–284 (1979).
[4] Di G., Dong L., Xie Z., Xu Y., Xiang J., Effects of power frequency electric field exposure on kidney, Ecotoxicology and Environmental Safety, vol. 194, no. 110354, pp. 1–6 (2020).
[5] Syrek P., Skowron M., The impact of overhead lines for employees with stents, IOP Conference Series: Materials Science and Engineering, vol. 200, no. 012013, pp. 1–6 (2017).
[6] Gas P., Miaskowski A., Implant Safety Tool Application to Assist the Assessment of Radio-Frequency Radiation Exposure, Journal of Ecological Engineering, vol. 20, no. 10, pp. 24–33 (2019).
[7] Oancea C.D., Calin F., Golea V., On the Electromagnetic Field in the Surrounding Area of Railway Equipment and Installations, 2019 International Conference on Electromechanical and Energy Systems (SIELMEN), Craiova, Romania, pp.1–5 (2019).
[8] Wen Y.H., Hou W.X., Research on Electromagnetic Compatibility of Chinese High Speed Railway System, Chinese Journal of Electronics, vol. 29, no. 1, pp. 16–21 (2020).
[9] Wrobel Z., The Electromagnetic Compatibility in Researches of Railway Traffic Control Devices, Lecture Notes in Electrical Engineering, vol. 452, pp. 275–287 (2018).
[10] ICNIRP, Guidelines for limiting exposure to time-varying electric and magnetic fields (1 Hz to 100 kHz), Health Physics, vol. 99, no. 6, pp. 818–836 (2010).
[11] 2013/35/EU: Directive of the European Parliament and of the Council of 26 June 2013 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (electromagnetic fields), Official Journal of the European Union, L 179, pp. 1–21 (2013).
[12] https://timgsa.baidu.com/timg?image&quality=80&size=b9999_10000&sec=1606369465878&di= 311321a9c108936454933bf4a777536f&imgtype=0&src=http%3A%2F%2Fy.zdmimg.com% 2F201711%2F08%2F5a02beb474f797348.jpg_e600.jpg, accessed on December 2020.
[13] http://5b0988e595225.cdn.sohucs.com/images/20181002/5b1720a89c7a456c9cebb2696008ae14.jpeg, accessed on December 2020.
[14] Gas P., Wyszkowska J., Influence of multi-tine electrode configuration in realistic hepatic RF ablative heating, Archives of Electrical Engineering, vol. 68, no. 3, pp. 521–533 (2019).
[15] Stuchly M.A., Dawson T.W., Human body exposure to power lines: relation of induced quantities to external magnetic fields, Health Physics, vol. 83, no. 3, pp. 333–340 (2002).
[16] Lu M., Ueno S., Computational study toward deep transcranial magnetic stimulation using coaxial circular coils, IEEE Transactions on Biomedical Engineering, vol. 62, no. 12, pp. 2911–2919 (2015).
[17] Bidi M., Biological risk assessment of high-voltage transmission lines on worker’s health of electric society, Archives of Electrical Engineering, vol. 69, no. 1, pp. 57–68 (2020).
[18] Bakker J.F., Paulides M.M., Neufeld E., Christ A., Chen X.L., Kuster N., Van Rhoon G.C., Children and adults exposed to low-frequency magnetic fields at the ICNIRP reference levels: Theoretical assessment of the induced electric fields, Physics Medicine Biology, vol. 57, no. 7, pp. 1815–1829 (2012).
[19] Tian R., Lu M., Safety assessment of electromagnetic exposure in high-speed train carriage with full passengers, Annals of Work Exposures and Health, vol. 64, no. 8, pp. 838–851 (2020).
[20] Alvin R.T., Ergonomics diagram – human factors in design, translated by Zhu T., China Architecture and Building Press (1998).
[21] Rush S., Driscoll D.A., Current distribution in the brain from surface electrodes, Anaesthesia and Analgesia, vol. 47, no. 6, pp. 717–723 (1968).
[22] http://niremf.ifac.cnr.it/tissprop/htmlclie/htmlclie.php, accessed on December 2020.
[23] Keikko T., Isokorpi J., Korpinen L., Practical problems in calculating electric fields of transmission lines, Eleventh International Symposium on High Voltage Engineering, London, UK, vol. 2, pp. 103–106 (1999).
Go to article

Authors and Affiliations

Chang-Qiong Yang
1
ORCID: ORCID
Mai Lu
1
ORCID: ORCID

  1. Lanzhou Jiaotong University, China

This page uses 'cookies'. Learn more