The attenuating properties of biological tissue are of great importance in ultrasonic medical imaging. Investigations performed in vitro and in vivo showed the correlation between pathological changes in the tissue and variation of the attenuation coefficient. In order to estimate the attenuation we have used the downshift of mean frequency (fm) of the interrogating ultrasonic pulse propagating in the medium. To determine the fm along the propagation path we have applied the fm estimator (I/Q algorithm adopted from the Doppler mean frequency estimation technique). The mean-frequency shift trend was calculated using Single Spectrum Analysis. Next, the trends were converted into attenuation coefficient distributions and finally the parametric images were computed. The RF data were collected in simulations and experiments applying the synthetic aperture (SA) transmit-receiving scheme. In measurements the ultrasonic scanner enabling a full control of the transmission and reception was used. The resolution and accuracy of the method was verified using tissue mimicking phantom with uniform echogenicity but varying attenuation coefficient.
The pathological states of biological tissue are often resulted in attenuation changes. Thus, information about attenuating properties of tissue is valuable for the physician and could be useful in ultrasonic diagnosis. We are currently developing a technique for parametric imaging of attenuation and we intend to apply it for in vivo characterization of tissue. The attenuation estimation method based on the echoes mean frequency changes due to tissue attenuation dispersion, is presented. The Doppler IQ technique was adopted to estimate the mean frequency directly from the raw RF data. The Singular Spectrum Analysis technique was used for the extraction of mean frequency trends. These trends were converted into attenuation distribution and finally the parametric images were computed. In order to reduce variation of attenuation estimates the spatial compounding method was applied. Operation and accuracy of attenuation extracting procedure was verified by calculating the attenuation coefficient distribution using the data from the tissue phantom (DFS, Denmark) with uniform echogenicity while attenuation coefficient underwent variation.
Noise reduction inside waveguide systems has gained momentum owing to a great interest in it. To attenuate the sound in a broad frequency range, this study aims to compare the effects of two acoustic liners, a perforated plate backed by an air cavity (PP-Air cavity), or by a porous material (PP-PM), on the acoustic behaviour of lined ducts using a numerical model to compute the multimodal scattering matrix. From this matrix, the reflection and the transmission coefficients are computed and therefore the acoustic power attenuation is deduced. Moreover, the effects of geometry of ducts with and without changes in the section are investigated. The numerical results are obtained for five configurations, including cases of narrowing and widening of a duct portion with sudden or progressive discontinuities. Accordingly, numerical coefficients of reflection and transmission as well as the acoustic power attenuation show the relative influence of acoustic liners in each type of configuration.
Duck viral hepatitis (DVH) is an acute and fatal disease of young ducklings characterized by rapid transmission and damages. The most important agent of DVH is duck hepatitis virus 1 (DHV-1). The effective control of DVH was achieved by active immunization of 1-day-old duck- lings with an attenuated DHV-1 virus vaccine. However, the attenuated virus might reverse to virulence. In this study, a DHV-1 strain, Du/CH/LBJ/090809, was identified and its genomic se- quences were determined. The genome of Du/CH/LBJ/090809 is composed of 7,692 nt excluding poly A and the virus was clustered into genotype A by comparing with other referenced DHV-1 strains. Du/CH/LBJ/090809 could lead to 30% mortality of 10-day-old specific pathogen free (SPF) ducklings. The virus was passaged serially in SPF chicken embryonated eggs and three vi- ruses, passage 16 (P16), P29 and P40, were selected for genomic analysis. P29 and P40 were used to evaluate the attenuation in duckling by inoculating the virus to 10-day-old SPF ducklings. Re- sults of vaccination-challenge assay showed that the inactivated virus P40 could evoke protection against the pathogenic parent virus. Nucleotide and amino acid sequences of the genomes of Du/ CH/LBJ/090809, P16, P29 and P40 were compared. Changes both in nucleotides and amino acids, which might be contributed to the decreasing in virulence by chicken embryo-passaging of DHV- 1, were observed. We speculated that these changes might be important in the adaption and at- tenuation of the virulent virus. Additionally, strains obtained in this study will provide potential candidate in the development of vaccines against DHV-1.
In this paper analyses of mode distribution, confinement and experimental losses of the photonic crystal fibers with different core sizes infiltrated with liquid crystal are presented. Four types of fibers are compared: with single-, seven-, nineteen- and thirty seven solid rods forming the core in the same hexagonal lattice of seven “rings” of unit cells (rods or capillaries). The experimental results confirming the influence of the core diameter on light propagation are also included. The diameter of cores determines not only the number of modes in the photonic liquid crystal fiber but also is correlated with experimentally observed attenuation. For fibers with larger cores confinement losses are expected to be higher, but the measured attenuation is smaller because the impact of liquid crystal material losses and scattering is smaller.
The impulse noise is agent harmful to health not only in the case of shots from firearms and the explosions of explosive materials. This kind of noise is also present in many workplaces in the industry. The paper presents the results of noise parameters measurements in workplaces where four different die forging hammers were used. The measured values of the C-weighted peak sound pressure level, the A-weighted maximum sound pressure level and A-weighted noise exposure level normalized to an 8 h working day (daily noise exposure level) exceeded the exposure limit values. For example, the highest measured value of the C-weighted peak sound pressure level was 148.9 dB. In this study possibility of the protection of hearing with the use of earplugs or earmuffs was assessed. The measurement method for the measurements of noise parameters under hearing protection devices using an acoustical test fixture instead of testing with the participation of subjects was used. The results of these measurements allows for assessment which of two tested earplugs and two tested earmuffs sufficiently protect hearing of workers in workplaces where forging hammers are used.
The paper is devoted to grain-refinement of the medium-aluminium zinc based alloys (MAl-Zn). The system examined was sand cast Zn10
wt. %. Al binary alloy (Zn-10Al) doped with commercial Al-3 wt. % Ti – 0.15 wt. % C grain refiner (Al-3Ti-0.15C GR). Basing on the
measured attenuation coefficient of ultrasonic wave it was stated that together with significantly increased structure fineness damping
decreases only by about 10 – 20%. The following examinations should establish the influence of the mentioned grain-refinement on
strength and ductility of MAl-Zn cast alloys.
Internal casting defects that are detected by radiography may also be detected by ultrasonic method. Ultrasonic testing allows investigation of the cross-sectional area of a casting, it is considered to be a volumetric inspection method. The high frequency acoustic energy travels through the casting until it hits the opposite surface or an interface or defect. The interface or defect reflects portions of the energy, which are collected in a receiving unit and displayed for the analyst to view. The pattern of the energy deflection can indicate internal defect. Ultrasonic casting testing is very complicated in practice. The complications are mainly due to the coarse-grain structure of the casting that causes a high ultrasound attenuation. High attenuation then makes it impossible to test the entire volume of material. This article is focused on measurement of attenuation, the effect of probe frequency on attenuation and testing results.
The article discusses the issues of accounting the direction pattern of parametric antenna array the propagation of sound over the Earth’s surface. As a radiator, a parametric antenna array is used. A description is given of measuring equipment and experimental research methods. The Delaney-Bezley model was used as a model of the Earth’s surface impedance. The research results showed the importance of accounting the direction pattern of parametric antenna array in predicting the sound pressure level of a propagating acoustic signal over the Earth’s surface. On the example of a difference signal with a frequency of 2 kHz, the calculation of the sound pressure level on a 100-meter path with the influence of the Earth’s surface is shown. The results obtained showed a good agreement between the theoretical calculation and experimental data.