In this paper a comparison of numerically determined and measured electromagnetically exited noise of an induction motor is presented. The calculations are accomplished using FEM for an example motor, which is a 290 kW inverter-fed asynchronous machine. The approach starts with the electromagnetic and mechanical consideration. The focus is set on acoustic considerations, which contain the 3D-FE-model and measurement setup in the sound chamber.
In the present work, the radiation of sound waves from a coaxial duct is considered. This coaxial duct has an inner wall which is infinite and has piecewise acoustically absorbent material, while the outer wall is semi-infinite and rigid. The analytical solution of the problem is found by means of the Wiener-Hopf technique. Applying the Fourier transformation to the boundary value problem, the explicit expression for the scattered field is obtained. In the end, some numerical results are displayed for different parameters and compared to rigid case.