Abstract

The paper presents an analysis of relations describing entropy generation in a condenser of a steam unit. Connections between entropy generation, condenser ratio, and heat exchanger effectiveness, as well as relations implied by them are shown. Theoretical considerations allowed to determine limits of individual parameters which describe the condenser operation. Various relations for average temperature of the cold fluid were compared. All the proposed relations were verified against data obtained using a simulator and actual measurement data from a 200 MW unit condenser. Based on data from a simulator it was examined how the sum of entropy rates, steam condenser effectiveness, terminal temperature difference and condenser ratio vary with the change in the inlet cooling water temperature, mass flow rate of steam and the cooling water mass flow rate.
Go to article

Authors and Affiliations

Rafał Laskowski
Maciej Jaworski
Adam Smyk
Download PDF Download RIS Download Bibtex

Abstract

The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
Go to article

Bibliography

[1] Salij A., Stepien J.C.: Performance of Turbine Condensers in Power Units of Thermal Systems. Kaprint, Warsaw 2013 (in Polish).
[2] Rusowicz A.: Issues Concerning Mathematical Modelling of Power Condensers. Warsaw University of Technology, Warsaw 2013 (in Polish).
[3] Grzebielec A., Rusowicz A.: Thermal resistance of steam condensation in horizontal tube bundles. J. Power Technol. 91(2011), 1, 41–48.
[4] Laskowski R., Smyk A., Rusowicz A., Grzebielec A.: Selection of cooling water mass flow rate at variable load for 200 MW power unit. Rynek Energii (2020), 3,41– 46 (in Polish).
[5] Durmayaz A., Sogut O. S.: In?uence of cooling water temperature on the e?ciency of a pressurized-water reactor nuclear-power plant. Int. J. Energ. Res. 30(2006), 10, 799–810.
[6] Atria S.I.: The influence of condenser cooling water temperature on the thermal efficiency of a nuclear power plant. Ann. Nucl. Energy 80(2015), 371–378.
[7] Lakovic M.S., et.al. Stojiljkovic M.M. , Lakovic S.V., Stefanovic V.P., Mitrovic D.D.: Impact of the cold end operating conditions on energy efficiency of the steam power plants. Therm. Sci. 14(2010), Suppl., S53–S66.
[8] Laskowski R., Smyk A., Lewandowski J., Rusowicz A.: Cooperation of a steam condenser with a low-pressure part of a steam turbine in off-design conditions. Am. J. Energ. Res. 3(2015), 1, 13–18.
[9] Cengel Y.A.: Heat Transfer. McGraw-Hill, 1998.
[10] Holman J.P.: Heat Transfer. McGraw-Hill, New York 2002.
[11] Weber G.E., Worek W.M.: Development of a method to evaluate the design performance of a feedwater heater with a short drain cooler. J. Eng. Gas Turbines Power 116(1994), 2, 434–441.
[12] Weber G.E., Worek W.M.: The application of a method to evaluate the design performance of a feedwater heater with a short drain cooler. J. Eng. Gas Turbines Power 117(1995), 2, 384–387.
[13] Szkłowier G.G., Milman O.O.: Research and Calculations of Condensing Systems of Steam Turbines. Energoatomizdat, Moskwa 1985 (in Russian).
[14] Pattanayak L., Padhi B.N., Kodamasingh B.: Thermal performance assessment of steam surface condenser. Case Stud. Therm. Eng. 14(2019), 100484.
[15] Beckman G., Heil G.: Mathematische Modelle für die Beurteilung von Kraftwerksprozessen. EKM Mitteillungen (1965), 10.
[16] Laskowski R., Lewandowski J.: Simplified and approximated relations of heat transfer effectiveness for a steam condenser. J. Power Technol. 92(2012), 4, 258– 265.
[17] Laskowski R.M.: A mathematical model of the steam condenser in the changed conditions. J. Power Technol. 92(2012), 2, 101–108.
[18] Szapajko G., Rusinowski H.: Empirical modelling of heat exchangers in a CHP plant with bleed-condensing turbine. Arch. Thermodyn. 29(2008), 4, 177–184.
[19] Szapajko G., Rusinowski H.: Mathematical modelling of steam–water cycle with auxiliary empirical functions application. Arch. Thermodyn. 31(2010), 2, 165–183.
[20] Bahadori A.: Simple method for estimation of effectiveness in one tube pass and one shell pass counter-flow heat exchangers. Appl. Energ. 88(2011), 11, 4191–4196.
[21] Vera-García F., García-Cascales J.R., Gonzálvez-Maciá J., Cabello R., Llopis R., Sanchez D., Torrella E.: A simplified model for shell-and-tubes heat exchangers: practical application. Appl. Therm. Eng. 30(2010), 10, 1231–1241.
[22] Patrascioiu C., Radulescu S.: Modeling and simulation of the double tube heat exchanger. Case studies. Advances in Fluid Mechanics & Heat & Mass Transfer (P. Mastny, V. Perminov, Eds.). In: Proc. 10th WSEAS Int. Conf. on Heat Transfer, Thermal Engineering and Environment (HTE ’12) and Proc. 10th WSEAS Int. Conf. on Fluid Mechanics & Aerodynamics (FMA ’12), Istanbul, Aug. 21–23, 2012, WSEAS, 2012, 35–41.
[23] Patrascioiu C., Radulescu S.: Prediction of the outlet temperatures in triple concentric-tube heat exchangers in laminar flow regime: case study. Heat Mass Transfer 51(2015), 59–66.
[24] Laskowski R.: The black box model of a double-tube counter-flow heat exchanger. Heat Mass Transfer (2014), 10.1007/s00231-014-1482-2.
[25] Chmielniak T., Trela M., Eds.: Diagnostics of New-Generation Thermal Power Plants. Wyd. IMP PAN, Gdansk 2008.
[26] Butrymowicz D., Trela M.: Influence of fouling and inert gases on the performance of regenerative feedwater heaters. Arch. Thermodyn. 23(2002), 1-2, 127–140.
[27] Badur J., Kowalczyk T., Ziółkowski P., Tokarczyk P., Wozniak M.: Study of the effectiveness of the turbine condenser air extraction system using hydro ejectors. Trans. Inst. Fluid-Flow Mach. 131(2016), 41–53.
[28] Tokarczyk P.,Woznizk M., Badur J., Kowalczyk T., Ziółkowski P.: Issue of the temperature of water supplied to hydro ejector and its influence on performance of steam turbine condenser. Energetyka 70(2017), 10 (in Polish).
[29] HEI Standards for Steam Surface Condensers (11th Edn.). Heat Exchange Institute, Cleveland 2012.
[30] Prieto M.M., Suárez I.M., Montanés E.: Analysis of the thermal performance of a church window steam condenser for different operational conditions using three models. Appl. Therm. Eng. 23(2003), 2, 163–178.
[31] Wróblewski W., Dykas S., Rulik S.: Selection of the cooling system configuration for an ultra-critical coal-fired power plant. Energ. Convers. Manage. 76(2013), 554– 560.
[32] Jian-qun Xu, Tao Yang, You-yuan Sun, Ke-yi Zhou, Yong-feng Shi: Research on varying condition characteristic of feedwater heater considering liquid level. Appl. Therm. Eng., 67 (2014), 179–189.
[33] Laskowski R.: Relations for steam power plant condenser performance in off-design conditions in the function of inlet parameters and those relevant in reference conditions. Appl. Therm. Eng. 104(2016), 528–536.
[34] Laskowski R., Smyk A., Rusowicz A., Grzebielec A.: A useful formulas to describe the performance of a steam condenser in off-design conditions. Energy 204(2020) 117910.
[35] Wagner W., Kretzschmar H.J.: International Steam Tables – Properties of Water and Steam based on the Industrial Formulation IAPWS-IF97. Springer, 2008.
Go to article

Authors and Affiliations

Rafał Laskowski
1
Adam Smyk
1
Adam Ruciński
1
Jacek Szymczyk
1

  1. Institute of Heat Engineering, Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Nowowiejska 21/25, 00-665 Warsaw, Poland
Download PDF Download RIS Download Bibtex

Abstract

This paper presents the results of an experimental study and
mathematical modeling of the effect of dynamic instabilities on the condensation phase transformation of the refrigerants homogeneous R134a and its replacement in the form of isomers R1234yf and R1234ze and R404A or R507 and R448A in pipe mini-channels. In the case of homogeneous chlorofluorocarbons (CFCs), it is the 1234 isomers that are envisioned as substitutes for the withdrawn ones with high ozone depletion potential and global warming potential. For zeotropic and azeotropic mixtures, for example, these are R507 or R448A. The paper presents a dimensional analysis procedure based on the Buckingham Π theorem to develop a regression velocity model of pressure dynamic instabilities. The experimental part of the work was carried out with the use of tubular mini-channels with internal diameter 1.40–3.3 mm.
Go to article

Authors and Affiliations

Waldemar Kuczyński
1

  1. Koszalin University of Technology, Faculty of Mechanical Engineering, Department of Power Engineering, Racławicka 15-17, 75-625 Koszalin, Poland
Download PDF Download RIS Download Bibtex

Abstract

W sytuacji niestabilności i zmian, które charakteryzowały Związek Radziecki w latach dwudziestych ubiegłego wieku, grupa architektów-konstruktywistów pod przewodnictwem Moisieja Ginzburga zajmowała się problemem braku mieszkań dla pracowników w dużych sowieckich miastach. Rozwiązania wypracowane przez zespół Ginzburga zostały opracowane pod patronatem Sowieckich platform OSA i Strojkom. Zostały przeprowadzone w trzech kolejnych etapach zwieńczonych budową Domu Narkomfinu. Niemniej, architektoniczna nowoczesność osiągnięta w Narkomfinie była związana z postępami w sektorze budownictwa mieszkaniowego poczynionymi przez ich kolegów z Europy. Niniejszy artykuł podejmuje analizę faktycznych powiązań pomiędzy owym moskiewskim prototypem a zachodnimi modelami, które zaczynały być opracowywane w Europie, a zwłaszcza w Niemczech. Przedmiotowa koncepcja umieszcza badania prowadzone przez zespół Ginzburga w procesie skomplikowanej i niezwykle ważnej asymilacji, która integrowała nowe modernistyczne techniki Zachodu.
Go to article

Authors and Affiliations

Daniel Movilla Vega
Adolfo Sotoca
Mateusz Gyurkovich
Download PDF Download RIS Download Bibtex

Abstract

Combi-steamer condensation hoods are widely used in modern gastronomy. They condense steam produced by the combi-steamer and also filter solid particles, moisture, grease and smells. All these factors negatively affect the staff and dishes, so efficient work of the condensation hoods becomes important. A mathematical and experimental analysis of such a device is described in this paper. First a measurement methodology was designed and measurements of air humidity, temperature and mass flow rates were performed. The measurement procedure concerned dedicated a steam generator and combi-steamer. Next a mathematical model was developed. It was based on mass and energy balances of the condensation hood. The condensate flow rate turned out to be insufficient to fulfill the energy balance while measured directly. Hence, it was calculated from heater’s power of the steam generator and the balance model was validated. The combisteamer had an unknown output, so the condensate flow rate was provided by the balance model after its validation. A preliminary diagnosis of the device was carried out as well.

Go to article

Authors and Affiliations

Mieszko Tokarski
Arkadiusz Ryfa
Piotr Buliński
Marek Rojczyk
Krzysztof Ziarko
Andrzej J. Nowak
Download PDF Download RIS Download Bibtex

Abstract

This paper presents a comparison of three surface condenser connection setups on the cooling water side. Four connections were considered, namely serial, mixed and two parallel ones. The analysis was conducted based on the calculated heat balances of proposed power unit for nominal and not nominal parameters for tested connections. Thermodynamic justification for the use of more complex configuration was verified. The exhaust steam pressure calculation was presented. Three methods of computing the heat transfer coefficient based on characteristic numbers, namely the Heat Exchange Institute (HEI) method, and the American Society of Mechanical Engineers (ASME) standard, were used. Calculation results were validated with the real data. The most accurate model was indicated and used in heat balance calculations. The assumptions and simplifications for the calculations are discussed. Examples of the calculation results are presented.

Go to article

Authors and Affiliations

Ewa Dobkiewicz-Wieczorek
Download PDF Download RIS Download Bibtex

Abstract

Experts from Poland are involved in designing and building the world’s strongest pulsed neutron source for investigating the properties of condensed matter.
Go to article

Authors and Affiliations

Dariusz Bocian
Wojciech Zając
Download PDF Download RIS Download Bibtex

Abstract

The image analysis consists in extracting from the information which is available to the observer of the part that is important from the perspective of the investigated process. This process usually accompanies a considerable reduction in the amount of information from the image. In the field of two-phase flows, computer image analysis can be used to determine flow and geometric parameters of flow patterns. This article presents the possibilities of using this method to determine the void fraction, vapor quality, bubble velocity and the geometric dimensions of flow patterns. The use of computer image analysis methods is illustrated by the example of HFE 7100 refrigerant methoxynonafluorobutane condensation in a glass tubular minichannel. The high speed video camera was used for the study, and the films and individual frames received during the study were analyzed.

Go to article

Authors and Affiliations

Małgorzata Sikora
Tadeusz Bohdal
Download PDF Download RIS Download Bibtex

Abstract

The internal diameter of a tube in a ‘church window’ condenser was estimated using an entropy generation minimization approach. The adopted model took into account the entropy generation due to heat transfer and flow resistance from the cooling-water side. Calculations were performed considering two equations for the flow resistance coefficient for four different roughness values of a condenser tube. Following the analysis, the internal diameter of the tube was obtained in the range of 17.5 mm to 20 mm (the current internal diameter of the condenser tube is 22 mm). The calculated diameter depends on and is positively related to the roughness assumed in the model.
Go to article

Authors and Affiliations

Artur Rusowicz
Rafał Laskowski
Andrzej Grzebielec
Download PDF Download RIS Download Bibtex

Abstract

Proposed is the analysis of steam condensation in the presence of inert gases in a power plant condenser. The presence of inert, noncondensable gases in a condenser is highly undesirable due to its negative effect on the efficiency of the entire cycle. In general, thermodynamics has not provided an explicit criterion for assessing the irreversible heat transfer process. The method presented here enables to evaluate precisely processes occurring in power plant condensers. This real process is of particular interest as it involves a number of thermal layers through which heat transfer is observed. The analysis was performed using a simple, known in the literature and well verified Berman’s model of steam condensation in the presence of non-condensable gases. Adapted to the geometry of the condenser, the model enables, for instance, to recognise places where non-condensable gases are concentrated. By describing with sufficient precision thermodynamic processes taking place in the vicinity of the heat transfer area segment, it is possible to determine the distributions of thermodynamic parameters on the boundaries between successive layers. The obtained results allow for the recognition of processes which contribute in varying degrees to irreversible energy degradation during steam condensation in various parts of the examined device.

Go to article

Authors and Affiliations

Zbigniew Drożyński
Download PDF Download RIS Download Bibtex

Abstract

The present paper describes the results of experimental investigations of heat transfer during condensation of R134a, R404A and R407C in pipe minichannels with internal diameters 0.31-3.30 mm. The results concern investigations of the local heat transfer coefficient. The results were compared with the correlations proposed by other authors. Within the range of examined parameters of the condensation process in minichannels made of stainless steel, it was established that the values of the heat transfer coefficient may be described with Akers et al., Mikielewicz and Shah correlations within a limited range of the mass flux density of the refrigerant and the minichannel diameter. On the basis of experimental investigations, the authors proposed their own correlation for the calculation of local heat transfer coefficient.
Go to article

Authors and Affiliations

Tadeusz Bohdal
Henryk Charun
Małgorzata Sikora
Download PDF Download RIS Download Bibtex

Abstract

Asynchronized (doubly-fed) machines with two (three) excitating winding and reversing excitation system allow to control vector of magnetomotive force. This solution allows separating regulation of the electromagnetic torque (active power) and voltage (reactive power). This paper describes the experience in the development and operation of asynchronized turbogenerators and condensers.

Go to article

Authors and Affiliations

Yury Shakaryan
Pavel Sokur
Download PDF Download RIS Download Bibtex

Abstract

The paper deals with the wet steam flow in a steam turbine operating in a nuclear power plant. Using a pneumatic and an optical probe, the static pressure, steam velocity, steam wetness and the fine water droplets diameter spectra were measured before and beyond the last turbine low-pressure stage. The results of the experiment serve to understand better the wet steam flow and map its liquid phase in this area. The wet steam data is also used to modify the condensation model used in computational fluid dynamics simulations. The condensation model, i.e. the nucleation rate and the growth rate of the droplets, is adjusted so that results of the numerical simulations are in a good agreement with the experimental results. A 3D computational fluid dynamics simulations was performed for the lowpressure part of the turbine considering non-equilibrium steam condensation. In the post-processing of the of the numerical calculation result, the thermodynamic wetness loss was evaluated and analysed. Loss analysis was performed for the turbine outputs of 600, 800, and 1100 MW, respectively.
Go to article

Bibliography

[1] Walters P.T., Skingley P.C.: An optical instrument for measuring the wetness fraction and droplet size of wet steam flow in LP turbines. In: Proc. Conf. on Steam Turbines for the 1980s, Vol. 12, London, 9–12 Oct. 1979, C141, 337–348.
[2] Kleitz A., Laali, A.R., Courant J.J.: Fog droplet size measurement and calculation in wet steam turbines. In: Proc. Int. Conf. on Technology of Turbine Plant Operating in Wet Steam (J.M. Mitchell, Ed.), London, 11–13 October 1988, 201– 206.
[3] Petr V., Kolovratník M.: Modelling of the droplet size distribution in LP steam turbine. In: Proc. 3rd Eur. Conf. on Turbomachinery – B, Fluid Dynamics and Thermodynamics, London, 2–5 March 1999, 771–782.
[4] Starzmann J., Schatz M., Casey M.V., Mayer J.F., Sieverding F.: Modelling and validation of wet steam flow in a low pressure steam turbine. In: Proc. ASME Turbo Expo 2011, Vancouver, June 6–10, 2011, GT2011-45672, 2335–2346.
[5] Hideaki S., Tabata S. Tochitani N., Sasao Y., Takata R., Osako M.: Investigation of moisture removal on last stage stationary blade in actual steam turbine. In: Proc. ASME Turbo Expo 2020, virtual, online, Sept. 21–25, 2020, GT2020-14831.
[6] Grübel M., Starzmann J., Schatz M., Eberle T., Vogt D.M., Sieverding F.: Two-phase flow modeling and measurements in low-pressure turbines – Part I: numerical validation of wet steam models and turbine modeling. J. Eng. Gas Turbines Power 137(2015), 4, 042602 (11), GTP-14-1442.
[7] Starzmann J., Hughes F. R., White, A., et al.: Results of the International Wet Steam Modelling Project. In: Proc. Wet Steam Conference. Prague, Sept. 12–14, 2016.
[8] Fendler Y., Dorey J.M., Stanciu M., Lance M., Léonard O.: developments for modeling of droplets deposition and liquid film flow in a throughflow code for steam turbines. In: Proc. ASME Turbo Expo 2012, Copenhagen, June 11–15, 2012, GT2012-68968, 537–547.
[9] Gyarmathy G.: Grundlagen einer Theorie der Nassdampfturbine. PhD thesis, ETH Zurich, Juris-Verlag, Zurich 1962.
[10] Laali A.R.: A new approach for assessment of the wetness losses in steam turbines. In Proc. IMechE Conf. Turbomachinery – Latest Developments in a Changing Scene, London, March, 1991, 155–166.
[11] Wróblewski W, Chmielniak T., Dykas S.: Models for water steam condensing flows. Arch. Thermodyn. 41 (2020), 4, 63–92.
[12] Petr V., Kolovratník M.: Wet steam energy loss and related Baumann rule in low pressure steam turbines. P. I. Mech. Eng. A-J. Pow. 228(2014), 2, 206–215.
[13] Holmberg H., Ruohonen P., Ahtila P.: Determination of the real loss of power for a condensing and a backpressure turbine by means of second law analysis. Entropy 11 (2009), 4, 702–712.
[14] Gardzilewicz A.: Evaluating the efficiency of low pressure part of steam turbines based on probing measurements. Trans. Inst. Fluid-Flow Mach. 135(2017), 41–56.
[15] Míšek T., Kubín Z.: Static and dynamic analysis of 1 220 mm steel last stage blade for steam turbine. Appl. Comput. Mech. 3(2009), 1, 133–140.
[16] Luxa M. Safarík P., Synác J., Rudas B.: High-speed aerodynamic investigation of the midsection of a 48” rotor blade for the last stage of steam turbine. In: Proc: 10th Eur. Conf. on Turbomachinery Fluid Dynamics and Thermodynamics, ETC10, Lappeenranta, Apr. 15–19, 2013, ETC2013-116.
[17] Finzel C., Schatz M., Casey M.V., Gloss D.: Experimental investigation of geometrical parameters on the pressure recovery of low pressure steam turbine exhaust hoods. In: Proc. ASME Turbo Expo 2011, Vancouver, June 6–10 2011, GT2011- 45302, 2255–2263.
[18] Jones M., Crossland R.: performance improvements of nuclear power plants by the application of longer LP last stage blades and advanced design techniques. In: ASME Power Conf., Baltimore, June 28–31, 2014; POWER2014-32072, V001T04A002.
[19] Hoznedl M., Kolovratník M., Bartoš O., Sedlák K., Kalista R., Mrózek L.: Experimental research on the flow at the last stage of a 1090 MW steam turbine. P. I. Mech. Eng. A-J. Pow 232(2018), 5, 515–524.
[20] Štastný M.: Flow field in the last steam turbine stage. In: Proc. 7th Eur. Conf. on Turbomachinery Fluid Dynamics and Thermodynamics , Euroturbo 7, Athens, March 5–9, 2007, 867–876.
[21] Kolovratník M., Bartoš O.: CTU optical probes for liquid phase detection in the 1000 MW steam turbine. In: Proc. EFM14 – Experimental Fluid Mechanics 2014, EPJ Web Conf. 92(2015), 02035.
[22] Brüggemann C., Schatz M., Vogt D.M., Popig F.: A numerical investigation of the impact of part-span connectors on the flow field in a linear cascade. In: Proc.ASME Turbo Expo 2017, Charlotte, June 26–30, 2017, GT2017-63359, V02AT40A005.
[23] Radnic T., Hála J., Luxa M., Šimurda D., Fürst J., Hasnedl D., Kellner, J.: Aerodynamic effects of tie-boss in extremely long turbine blades. ASME J. Eng. Gas Turbines Power. 140(2018), 11: 112604, GTP-17-1218.
[24] Häfele M. Traxinger C., Grübel M., Schatz M., Vog D.M., Drozdowski R.: Experimental and numerical investigation of the flow in a low-lressure industrial steam turbine with part-span connectors. In: Proc. ASME Turbo Expo 2015: Montreal. June 15–19, 2015, GT2015-42202, V008T26A005.
[25] Young J.B.: Spontaneous condensation of Steam in Supersonic Nozzles. 1980STIN...8113306Y, Whittle laboratory, Cambridge University, 1980
[26] Gerber A.G. Kermani M.J.: A pressure based Eulerian–Eulerian multi-phase model for non-equilibrium condensation in transonic steam flow. Int. J. Heat Mass Tran. 47(2004), 10–11, 2217–2231.
[27] Hill P.G.: Condensation of water vapour during supersonic expansion in nozzles. J. Fluid Mech. 25(1966), 3, 593–620.
[28] Ansys CFX. https://www.ansys.com/products/fluids/ansys-cfx (accessed 5 March 2021).
[29] The International Association for the Properties of Water and Steam. Revised Release on the IAPWS-97 Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam. http://www.iapws.org/relguide/IF97-Rev.html (accessed 15 Sept. 2020).
[30] Sova L., Jun G., Štastný M.: Modifications of steam condensation model implemented in commercial solver. AIP Conf. Proc. 1889(2017), 020039-1–020039-8.
[31] Petr V., Kolovratník M.: Heterogeneous effects in the droplet nucleation process in LP steam turbines. In: Proc. 4th Eur. Conf. on Turbomachinery Flud Dynamics and Thermodynamics (G. Bois, R. Decuypere, F. Martelli, Eds.), Firenze, 2001, 783–792.
[32] Baumann K.: Some recent developments in large steam turbine practice. J. Inst. Electr. Eng., 59(1921), 565–623.
[33] Moore M.J.: Gas dynamics of wet steam and energy losses in wet-steam turbines. In: Two-Phase Steam Flow in Turbines and Separators (M.J. Moore, C.H. Sieverding, Eds.). Hemisphere, Washington 1976, 59–126.
Go to article

Authors and Affiliations

Gukchol Jun
1 2
Michal Kolovratník
2
Michal Hoznedl
1

  1. Czech Technical University in Prague, Technická 4, 160 00, Prague, Czech Republic
  2. Doosan Škoda Power s.r.o., Tylova 1/57, 301 28, Pilsen, Czech Republic
Download PDF Download RIS Download Bibtex

Abstract

The paper presents studies of mathematical modelling in transonic flow through the first stage rotor of the axial compressor of homogenous and heterogeneous condensation. The condensation phenomena implemented into a commercial software is based on the classical theory of nucleation and molecular-kinetic droplet growth model. Model is validated against experimental studies available in the literature regarding the flow through the first stage of turbine compressor, i.e. the rotor37 transonic compressor benchmark test. The impact of air humidity and air contamination on the condensation process for different flow conditions is examined. The influence of latent heat release due to condensation exerts a significant impact on the flow structure, thus the analysis of the air humidity and contamination influence on the condensation is presented. The results presented indicate the non-negligible influence of air humidity on the flow structure in the transonic flow regime, thus it is recommended to take condensation phenomenon under consideration in high-velocity airflow simulations.

Go to article

Authors and Affiliations

Piotr Paweł Wiśniewski
Sławomir Dykas
Guojie Zhang
Download PDF Download RIS Download Bibtex

Abstract

The purpose of the study was to assess the impact of industrial wastewater on the concentration of methanol in the considered section of the Ob River basin, present proposals for the implementation of a new treatment system and analyse the implementation results. On the basis of the results of the analysis of the known methods for reducing the concentration of methanol in water, a new technological scheme for post-treatment of effluents using biological treatment with methylotrophic Methylomonas methanica Dg bacteria was proposed. The calculation of the dilution of treated wastewater using the “NDS Ecolog” program was carried out on the basis of the detailed calculation method of Karaushev, the results of which showed a decrease in the concentration of methanol in the control section to 0.0954 mg∙dm –3 (permissible concentration is 0.1 mg∙dm –3). During the period of the flood of the Glukhaya channel, it ceases to be a separate water body and, in fact, becomes part of the flood channel of the Ob River. Certain parts of the flooded areas, due to elevation changes, communicate with the channel only during a short period of time when the water level rises, i.e. 3–5 weeks during the flood period, and in fact remain isolated reservoirs for the rest of the time, potentially acting as zones of accumulation and concentration of pollutants.
Go to article

Authors and Affiliations

Andrey Ivanov
1
ORCID: ORCID
Alexey Strizhenok
1
ORCID: ORCID
Gabriel Borowski
2
ORCID: ORCID

  1. Saint-Petersburg Mining University, Faculty of Mining Engineering, 21st Line of Vasilyevsky island, 2, 199106, Saint-Petersburg, Russia
  2. Lublin University of Technology, Faculty of Environmental Engineering, Poland
Download PDF Download RIS Download Bibtex

Abstract

Water resources are the main component of natural systems affected by climate change in the Middle East. Due to a lack of water, steam power plants that use wet cooling towers have inevitably reduced their output power. This article investigates the replacement of wet cooling towers in Isfahan Thermal Power Plant (ITPP) with Heller natural dry draft cooling towers. The thermodynamic cycle of ITPP is simulated and the effect of condenser temperature on efficiency and output power of ITPP is evaluated. For various reasons, the possibility of installing the Heller tower without increasing in condenser temperature and without changing the existing components of the power plant was rejected. The results show an increase in the condenser temperature by removing the last row blades of the low-pressure turbine. However, by replacing the cooling tower without removing the blades of the last row of the turbine, the output power and efficiency of the power plant have decreased about 12.4 MW and 1.68 percent, respectively.
Go to article

Bibliography

[1] B. Dziegielewski and D. Baumann. Tapping alternatives: The benefits of managing urban water demands. Environment: Science and Policy for Sustainable Development, 34(9):6–41, 2010. doi: 10.1080/00139157.1992.9930929.
[2] D. Marmer. Water conservation equals energy conservation. Energy Engineering, 115(5):48–63, 2018. doi: 10.1080/01998595.2018.12027708.
[3] J.M. Burns, D.C. Burns, and J.S. Burns. Retrofitting cooling towers: estimates required to achieve the next level of CWA 316(b) compliance. In Proceedings of the ASME Power Conference, pages 25–33, 2004. doi: 10.1115/POWER2004-52051.
[4] A. Loew, P. Jaramillo, and H. Zhai. Marginal costs of water savings from cooling system retrofits: a case study for Texas power plants. Environmental Research Letters, 11(10):104004, 2016. doi: 10.1088/1748-9326/11/10/104004.
[5] A.E. Conradie and D.G. Kröger. Performance evaluation of dry-cooling systems for power plant applications. Applied Thermal Engineering, 16(3):219–232, 1996. doi: 10.1016/1359-4311(95)00068-2.
[6] A.E. Conradie, J.D. Buys, and D.G. Kröger. Performance optimization of dry-cooling systems for power plants through SQP methods. Applied Thermal Engineering, 18(1-2):25–45, 1998. doi: 10.1016/S1359-4311(97)00020-3.
[7] J.D. Buys and D.G. Kröger. Dimensioning heat exchangers for existing dry cooling towers. Energy Conversion and Management, 29(1):63–71, 1989. doi: 10.1016/0196-8904(89)90014-9.
[8] Z. Zou, Z. Guan, H. Gurgenci, and Y. Lu. Solar enhanced natural draft dry cooling tower for geothermal power applications. Solar Energy, 86(9):2686–2694, 2012. doi: 10.1016/j.solener.2012.06.003.
[9] S. Bagheri and M. Nikkhoo. Investigation of the optimum location for adding two extra Heller-type cooling towers in Shazand power plant. Proceedings of the 17th IAHR International Conference on Cooling Tower and Heat, pages. 74–83, Australia, 2015.
[10] W. Peng and O.K. Sadaghiani. Presentation of an integrated cooling system for enhancement of cooling capability in Heller cooling tower with thermodynamic analyses and optimization. International Journal of Refrigeration, 131:786–802, 2021. doi: 10.1016/j.ijrefrig.2021.07.016.
[11] M.A. Ardekani, F. Farhani, and M. Mazidi. Effects of cross wind conditions on efficiency of Heller dry cooling tower. Experimental Heat Transfer, 28(4):344–353, 2015. doi: 10.1080/08916152.2014.883449.
[12] A. Jahangiri, A. Borzooee, and E. Armoudli. Thermal performance improvement of the three aligned natural draft dry cooling towers by wind breaking walls and flue gas injection under different crosswind conditions. International Journal of Thermal Sciences, 137:288–298, 2019. doi: 10.1016/j.ijthermalsci.2018.11.028.
[13] A.R. Seifi, O.A. Akbari, A.A. Alrashed, F. Afshari, G.A.S. Shabani, R. Seifi, M. Goodarzi, and F. Pourfattah. Effects of external wind breakers of Heller dry cooling system in power plants. Applied Thermal Engineering, 129: 1124–1134, 2018. doi: 10.1016/j.applthermaleng.2017.10.118.
[14] R.A. Kheneslu, A. Jahangiri, and M. Ameri. Interaction effects of natural draft dry cooling tower (NDDCT) performance and 4E (energy, exergy, economic and environmental) analysis of steam power plant under different climatic conditions. Sustainable Energy Technologies and Assessments, 37:100599, 2020. doi: 10.1016/j.seta.2019.100599.
[15] A. Jahangiri and F. Rahmani. Power production limitations due to the environmental effects on the thermal effectiveness of NDDCT in an operating powerplant. Applied Thermal Engineering, 141:444–455, 2018. doi: 10.1016/j.applthermaleng.2018.05.108.
[16] A.D. Samani. Combined cycle power plant with indirect dry cooling tower forecasting using artificial neural network. Decision Science Letters, 7:131–142, 2018. doi: 10.5267/j.dsl.2017.6.004.
[17] T.L. Bergman, F.P. Incropera, D.P. DeWitt, and A.S. Lavine. Fundamentals of Heat and Mass Transfer. John Wiley & Sons, 2011.
[18] Archive of Isfahan Mohammad Montazeri Power Station. Isfahan, Iran, 1984.
[19] H. Ahmadikia and G. Iravani. Numerical and analytical study of natural dry cooling tower in a steam power plant. Journal of Advanced Materials in Engineering (Esteghlal), 26(1):183–195, 2007. (in Persian).
[20] H.G. Zavaragh, M.A. Ceviz, and M.T.S. Tabar. Analysis of windbreaker combinations on steam power plant natural draft dry cooling towers. Applied Thermal Engineering, 99:550–559, 2016. doi: 10.1016/j.applthermaleng.2016.01.103.
[21] K.F. Reinschmidt and R. Narayanan. The optimum shape of cooling towers. Computers & Structures, 5(5-6):321–325, 1975. doi: 10.1016/0045-7949(75)90039-5.
[22] Isfahan Thermal Power Plant documents, No. C.583 and C.749, Islam Abad Power Plant, Isfahan, Iran, 1988.
[23] I.H. Shames. Mechanics of Fluids. 4th ed. McGraw-Hill, New York, 2003.
[24] C.R.F. Azevedo and A. Sinátora. Erosion-fatigue of steam turbine blades. Engineering Failure Analysis, 16(2):2290–2303, 2009. doi: 10.1016/j.engfailanal.2009.03.007.
[25] H. Kim. Crack evaluation of the fourth stage blade in a low-pressure steam turbine. Engineering Failure Analysis, 18(3):907–913, 2011. doi: 10.1016/j.engfailanal.2010.11.004.
[26] L.K. Bhagi, P. Gupta, and V. Rastogi. Fractographic investigations of the failure of L-1 pressure steam turbine blade. Case Studies in Engineering Failure Analysis, 1(2):72–78, 2013. doi: 10.1016/j.csefa.2013.04.007.
Go to article

Authors and Affiliations

Mohamad Hasan Malekmohamadi
1 2
Hossein Ahmadikia
1
ORCID: ORCID
Siavash Golmohamadi
2
Hamed Khodadadi
3

  1. University of Isfahan, Isfahan, Iran
  2. Isfahan Thermal Power Plant, Isfahan, Iran
  3. Department of Electrical Engineering, Khomeinishahr Branch, Islamic Azad University, Isfahan, Iran
Download PDF Download RIS Download Bibtex

Abstract

The author, following the concept of E. Benveniste, considers complex words as a product not only of word-formation derivation, but also of syntactic trans-formation (condensation) of phrases. The object of the transformation is phrases as composite syntactic and semantic constructions, but the derivation itself, i.e. the formation of complex words is carried out in the language according to the same rules as the derivation of simple (not complex) words, and with the same formal techniques as word formation in general, i.e. by affixation and transformation of components of complex words (truncation, interfixation, accent shifts, etc.). At the same time, the syntactic and semantic relations between components that are characteristic of generating phrases retain their meaning in the structure of derived complex words, no matter what models of derivation (semantic and word-forming) they may relate to. Complex words of the same type in their word-formation structure can have completely different semantics, depending on the syntactic and semantic relations that link the components of the original phrases.

The article offers a typology of complex words in the Russian language in terms of their "internal" syntactic and semantic structure. In composites derived from predicative phrases, there are subject, object, locative, temporal, and other semantic models of relations between a predicate and a dependent word. Composites with a supporting noun can be derived both from phrases with a com-positional connection, and from phrases with a subordinate connection (with relations of functional, comparative, and attributive dependence in a broad sense). Similarly, composites with a reference adjective, numeral, and counting words are analyzed. The article contains a criticism of some provisions of the academic "Russian grammar" (1980).

Go to article

Authors and Affiliations

Светлана М. Толстая
ORCID: ORCID
Download PDF Download RIS Download Bibtex

Abstract

The paper presents selected issues relating to the energy analysis of the air heat pump for hot water. Experimental studies on a test stand made it possible to verify the operational parameters of the heat pump under actual conditions of use. The study shows that heating the water in the storage tank with the capacity of 130 dm3 from 25°C to 40°C took approximately 60 minutes and the water heating for another 5°C took 30 minutes longer. The heat pump process in the field of higher water temperature in the tank is less effective, thus heating the water in the tank above 50°C is less favorable economically.
Go to article

Authors and Affiliations

Mariusz Szreder
Download PDF Download RIS Download Bibtex

Abstract

Vapordynamic thermosyphon (VDT) is an efficient heat transfer device. The two-phase flow generation and dynamic interaction between the liquid slugs and vapor bubbles in the annular minichannel of the VDT condenser are the main features of such thermosyphon, which allowed to increase its thermodynamic efficiency. VDT can transfer heat in horizontal position over a long distance. The condenser is nearly isothermal with the length of tens of meters. The VDT evaporators may have different forms. Some practical applications of VDT are considered.
Go to article

Authors and Affiliations

Leonard Vasiliev
Leonid Vasiliev
Alexander Zhuravlyov
Aleksander Shapovalov
Aleksei Rodin
Download PDF Download RIS Download Bibtex

Abstract

The present paper describes results of experimental investigations of pressure drop during the condensation of R134a, R404a and R407C refrigerants in pipe minichannels with internal diameter 0.31-3.30 mm. The results concern investigations of the mean and local pressure drop in single minichannels. The results of experimental investigations were compared with the calculations according to the correlations proposed by other authors. A pressure drop during the condensation of refrigerants is described in a satisfactory manner with Friedel and Garimella correlations. On the basis of the experimental investigations, the authors proposed their own correlation for calculation of local pressure drop during condensation in single minichannels.
Go to article

Authors and Affiliations

Tadeusz Bohdal
Henryk Charun
Małgorzata Sikora
Download PDF Download RIS Download Bibtex

Abstract

Maritime transport is facing a set of technical challenges due to implementation of ecological criterions on 1st Jan. 2020 and 2021 by the International Maritime Organization. The advantageous properties of natural gas (NG) as fuel in conjunction with dual-fuel (DF) internal combustion engines (ICE) potentially enables the fulfilment of all criterions. Moreover the 2020 global sulfur cap in combination with its low content in NG potentially enables to recover higher rates of waste heat and exergy of exhaust gas without the risk of low temperature corrosion. In this study the influence of sulfur content in NG and pilot fuel oil (PFO) on the sulfuric acid condensation temperature was investigated in order to determine the rate of waste heat (quantity) and exergy (quality) of four-stroke DF IC engine’s exhaust for 50%, 85% and 100% of engine load. Determined parameters were compared with two sets of reference values calculated for the same engine: a) fueled with NG and PFO with fixed minimum exhaust temperature set as 423.15 K, b) fueled with 3.5% sulfur mass fraction fuel oil only with variable minimum exhaust gas temperature. The results show that the assumption of case a) can lead to significant reduction of recovered rates of exhaust waste heat and exergy in the ranges of 10% to 24% and 43% to 57%, respectively. Higher values were obtained for case b) where the ranges of unrecovered rate of heat and exergy achieved 20% to 38% and 60% to 70%.

Go to article

Authors and Affiliations

Mateusz Przybyła
Andrzej Adamkiewicz
Download PDF Download RIS Download Bibtex

Abstract

Helical coil heat exchangers are widely used in a variety of industry applications such as refrigeration systems, process plants and heat recovery. In this study, the effect of Reynolds number and the operating temperature on heat transfer coefficients and pressure drop for laminar flow conditions was investigated. Experiments were carried out in a shell and tube heat exchanger with a copper coiled pipe (4 mm ID, length of 1.7 m and coil pitch of 7.5 mm) in the temperature range from 243 to 273 K. Air – propan-2-ol vapor mixture and coolant (methylsilicone oil) flowed inside and around the coil, respectively. The fluid flow in the shell-side was kept constant, while in the coil it was varied from 6.6 to 26.6 m/s (the Reynolds number below the critical value of 7600). Results showed that the helical pipe provided higher heat transfer performance than a straight pipe with the same dimensions. The convective coefficients were determined using theWilson method. The values for the coiled pipe were in the range of 3–40 W/m2 ·K. They increased with increasing the gas flow rate and decreasing the coolant temperature.

Go to article

Authors and Affiliations

Krzysztof Kowalski
Dorota Downarowicz
Download PDF Download RIS Download Bibtex

Abstract

The present paper presents results of a study on hemp-lime composite – a novel building material which is gaining attention thanks to its pro-ecological values, as well as interesting hygrothermal characteristics. The thermal conductivity and vapour permeability tests were performed on composites which varied in terms of composition and density as a result of use of various binders, different proportions of ingredients in a mixture and different compaction level during manufacturing with the use of the tamping method. The results obtained, indicating low thermal conductivity and very high vapor permeability, were tabulated with results of compressive strength obtained in the previous study on the same types of composites. The conclusions emphasise supreme importance of apparent density on properties of material, rather than binder composition – which exerts a significant effect only on compressive strength. The results of the performed tests were applied for determination of external walls’ construction, which were subjected to analysis of risk of interstitial water vapor condensation according to Glaser method. For locations in all Polish climatic zones, no condensation or only a small amount thereof, in which case it does not accumulate in subsequent years, was found.
Go to article

Authors and Affiliations

Michał Gołębiewski
1
Barbara Pietruszka
2

  1. Warsaw University of Technology, Faculty of Architecture, ul. Koszykowa 55, 00-659 Warsaw, Poland
  2. Building Research Institute, Department of Thermal Physics, Acoustics and Environment, ul. Ksawerów 21, 00-656 Warsaw, Poland

This page uses 'cookies'. Learn more