Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

The solution of applications for air pollution control in foundries for iron and non-ferrous metals may not only be understood as the observance of requested emission limit values at the stack outlet. An effective environmental protection already starts with the greatest possible capture of pollutants at the source with at the same time minimisation of the volume flow necessary for this. Independent of this, the downstream installed filtration system has to realise a degree of separation of definitely above 99%. Furthermore, when selecting the filter construction, attention has to be paid to a high availability. An even temporarily production without filter will more and more no longer be accepted by residents and authorities. Incidents at the filter lead to a shutdown of the whole production. Additional measures for heat recovery while preparing concepts for filtration plants help to reduce the energy consumption and serve for a sustained conservation of environment. A consequent consideration of the items above is also condition for the fact that environmental protection in foundries remains affordable. The lecture deals with the subjects above from the point of view of a plant constructor.
Go to article

Authors and Affiliations

R. Margraf
Download PDF Download RIS Download Bibtex

Abstract

In the article, results of the air-quality experiment in a Nowy Sącz area have been presented. The experiment combining both calculations and measurements was done in July 1993. Its goal was to assess the capability of the ,,box-model" method for simulation time-series of ozone and other pollutants in the lowest layer of the atmosphere. The numeric calculations' results were verified by the measurements from the airquality monitoring network. The model's prognostic capacity was assessed by the qualitative and quantitative data analysis. For analyzed episode, the error of calculated maximum ozone concentrations did not exceed ±22% of measured maximum values. The calculated daily-average ozone concentrations were 29% lower comparing to measured values. TI1c errors of calculations were most probably due to the errors in distribution of depth of the mixing layer, assumed for the calculations.
Go to article

Authors and Affiliations

Marek Bogacki

This page uses 'cookies'. Learn more