The paper presents a multi-phase doubly fed induction machine operating as a DC voltage generator. The machine consists of a six-phase stator circuit and a three-phase rotor circuit. Two three-phase six-pulse diode rectifiers are connected to each three-phase machine section on the stator side and in parallel to the common DC circuit feeding the isolated load. The same DC bus is also common for the rotor side power electronics converter responsible for machine control. Two methods – direct torque control DTC and field oriented control FOC – were implemented for machine control and compared by means of simulation tests. Field oriented control was implemented in the laboratory test bench.
The actual load-bearing capacity of elements of a building system can be calculated by dynamic parameters, in particular by resonant frequency and compliance. The prerequisites for solving such a problem by the finite element method (FEM) are presented in the article. First, modern vibration tests demonstrate high accuracy in determination of these parameters, which reflects reliability of the diagnosis. Secondly, most modern computational complexes do not include a functional for calculating the load-bearing capacity of an element according to the input values of resonance frequencies. Thirdly, FEM is the basis for development of software tools for automating the computation process. The article presents the method for calculating flexural stiffness and moment of inertia of a beam construction system by its own frequencies. The method includes calculation algorithm realizing the finite element method.
We demonstrate MW-level, single resonance optical parametric oscillator, based on KTP Type-II crystal with noncritical phase-matching. The OPO is pumped by electro-optically Q-switched Nd:YAG slab laser providing 55 mJ of pulse energy. At the output, we achieved 28 mJ of signal pulse energy at 1.57 μm with 51% conversion efficiency, corresponding to 1.4 MW of peak power.
The hereby paper discusses the influence of cable length on the SHM systems with the use of vibrating wire dynamic measurements. Vibrating wire sensors are mainly used for measuring stable or slowly changing strains, e.g. system installed on Rędziński Bridge in Wroclaw. From some time applications of these sensors for measuring dynamic deformations are becoming popular. Such tests were conducted on STS Fryderyk Chopin. New solutions generate new problems. In this case: the operational stability of systems exciting wire vibrations. The structure of such sensors and the electric cables length has an essential influence on their operations, what is undertaken in the paper. The subject of investigations constitutes the measuring system based on self-exciting impulse exciter, for which impedance parameters of electric cables and of the vibrating wire sensor were the most essential. The mathematical model of the system, experimental verification of the model as well as the results of theoretical analyses at the application of electric cables of various lengths are presented in the paper.
This article proposes and examines a solution in which the base-station for the fifth generation radio access network is simplified by using a single millimeter-wave oscillator in the central-station and distributing its millimeter-wave signal to the base-stations. The system is designed in such a way that the low-phase-noise signal generated by an opto-electronic oscillator is transmitted from the central-station to multiple base-stations via a passive optical network infrastructure. A novel flexible approach with a single-loop opto-electronic oscillator at the transmitting end and a tunable dispersion-compensation module at the receiving end(s) is proposed to distribute a power-penalty-free millimeter-wave signal in the radio access network. Power-penalty-free signal transmission from 10 MHz up to 45 GHz with an optical length of 20 km is achieved by a combination of a tunable dispersion-compensation module and an optical delay line. In addition, measurements with a fixed modulation frequency of 39 GHz and discretely incrementing optical fiber lengths from 0.625 km to 20 km are shown. Finally, a preliminary idea for an automatically controlled feedback-loop tuning system is proposed as a further research entry point.