This work presents an application possibility of sorption refrigerators driven by low temperature fluid for air conditioning of buildings. Thermodynamic models were formulated and absorption LiBr-water chiller with 10 kW cooling power as well as adsorption chiller with silica gel bed were investigated. Both of them are using water for desorption process with temperature Tdes = 80 °C. Coefficient of performance (COP) for both cooling cycles was analyzed in the same conditions of the driving heat source, cooling water Tc = 25 °C and temperature in evaporator Tevap = 5 °C. In this study, the computer software EES was used to investigate the performance of absorption heat pump system and its behaviour in configuration with geothermal heat source.
Work on increasing the efficiency of heat exchangers used in car air conditioning systems may lead to a partial change in the construction of refrigeration systems. One of such changes is the use of smaller gas coolers, which directly translates into a reduction in the production costs of the entire system. The article presents the use of computational fluid dynamics methods to simulate the impact of changing the shape of an internal heat exchanger on the cooling efficiency with R744 as the refrigerant. Internal heat exchangers with different geometry of the outer channels were subjected to numerical analysis. The obtained results of calculations show temperature changes in inner and outer channels on the length of the heat exchanger.
The objective of the study reported in this paper was to determine the effect of structure on thermal power of cast-iron heat exchangers which in this case were furnace chambers constituting the main component of household fireplace-based heating systems and known commonly as fireplace inserts. For the purpose of relevant tests, plate-shaped castings were prepared of gray iron with flake graphite in pearlitic matrix (the material used to date typically for fireplace inserts) as well as similar castings of gray cast iron with vermicular graphite in pearlitic, ferritic-pearlitic, and ferritic matrix. For all the cast iron variants of different structures (graphite precipitate shapes and matrix type), calorimetric measurements were carried out consisting in determining the heat power which is quantity representing the rate of heat transfer to the ambient environment. It has been found that the value of the observed heat power was affected by both the shape of graphite precipitates and the type of alloy matrix. Higher thermal power values characterize plate castings of gray iron with vermicular graphite compared to plates cast of the flake graphite gray iron. In case of plates made of gray cast iron with vermicular graphite, the highest values of thermal power were observed for castings made of iron with ferritic matrix.
An attempt was made to determine the vertical momentum and heat exchange in the near-ground atmosphere layer in the specific conditions of a sub-Antarctic island. For this purpose, some of the results of the measurements of temperature and wind speed carried out at the levels 10, 2, 0.5 and 0.05 m, during the IVth Antarctic Expedition of the Polish Academy of Sciences in March 1980, were used. The vertical gradients of the two elements and the wind stress and the heat flux in the layers under study, were calculated.
On the basis of the results of direct measurements, the conduction properties of the yearly behaviour of the halt flux conducted in the tundra soil (S) are determined. In general, the cooling period of the soil profile lasted from August to January, with highest intensity in October (S = —4.8 Wm-2). A rapid intensification of the heat exchange in the soil occurred in July (S = 7.4 Wm-2 ) . The 24-hour values of S were found to vary greatly (from 19 Wm-2 to 32 Wm-2). For chosen days, relationships were determined among the particular elements of the heat balance of the active layer.
A cross-flow, tube and fin heat exchanger of the water – air type is the subject of the analysis. The analysis had experimental and computational form and was aimed for evaluation of radiative heat transfer impact on the heat exchanger performance. The main element of the test facility was an enlarged recurrent segment of the heat exchanger under consideration. The main results of measurements are heat transfer rates, as well as temperature distributions on the surface of the first fin obtained by using the infrared camera. The experimental results have been next compared to computational ones coming from a numerical model of the test station. The model has been elaborated using computational fluid dynamics software. The computations have been accomplished for two cases: without radiative heat transfer and taking this phenomenon into account. Evaluation of the radiative heat transfer impact in considered system has been done by comparing all the received results.
The paper presents analytical relationships based on the theory of Green’s functions. The relationships refer to instantaneous and continuous as well as point and ring heat sources which are discussed. The relationship relating to continuous ring source is the basis for modelling and designing of spiral ground heat exchangers. Heat transfer in the infinite and semi-infinite body was considered. In the latter case, the image method was discussed. Using the results of measurements regarding heat transfer in the ground with a heat exchanger in the form of a single coil installed, a comparison of calculated ground temperatures with measured values was presented.
Corrosion is a main problem for longtime exploration of heat exchangers in automotive industry. Proper selection of accelerated corrosion test for newly developed material is a key aspect for aluminum industry. The selection of material based on corrosion test includes test duration, chemical spray composition, temperature and number of cycles. The paper present comparison of old and newly developed accelerated corrosion tests for testing automotive heat exchanger. The accelerated test results are comprised with heat exchanger taken from market after life cycle.
Most of the formulations regarding the characteristics of a shell and tube heat exchanger have a common assumption; namely that the baffle plates are equidistant. This assumption fails to cater the real world scenario for defective baffles as the alteration in a shell and tube heat exchanger invalidates the equidistant baffle spacing of the plates. In this regard, a small six baffles heat exchanger was modeled in the computational fluid dynamics software package and studied by removing each baffle plate one at a time. Effect of removing each baffle plate on the temperature, pressure, heat transfer coefficient, and total heat transfer rate was recorded. It was observed that variation in the pressure drop for the same number of baffle plates varies along the axial order of the plates. The change in pressure drop due to the removal of the baffle plate near the inlet and the outlet was lowest and reaches a maximum in the axial center. It was also found that the plates below the radial center contribute higher towards the overall heat transfer as compared to those above.
A new expression is proposed to calculate the earth-energy of an earth-air-pipe heat exchanger during winter heating for three kinds of soil in France. An analytical model is obtained by using numerical computation developed in Scilab – a free open source software. The authors showed the comparison between their simple analytical model and experimental results. They showed the influence of different parameters to specify the size of the heat exchanger.
The paper presents an experimental investigation of a silicone based heat exchanger, with passive heat transfer intensification by means of surface enhancement. The main objective of this paper was to experimentally investigate the performance of a heat exchanger module with the enhanced surface. Heat transfer in the test section has been examined and described with precise measurements of thermal and flow conditions. Reported tests were conducted under steady-state conditions for single-phase liquid cooling. Proposed surface modification increases heat flux by over 60%. Gathered data presented, along with analytical solutions and numerical simulation allow the rational design of heat transfer devices.
Combi-steamer condensation hoods are widely used in modern gastronomy. They condense steam produced by the combi-steamer and also filter solid particles, moisture, grease and smells. All these factors negatively affect the staff and dishes, so efficient work of the condensation hoods becomes important. A mathematical and experimental analysis of such a device is described in this paper. First a measurement methodology was designed and measurements of air humidity, temperature and mass flow rates were performed. The measurement procedure concerned dedicated a steam generator and combi-steamer. Next a mathematical model was developed. It was based on mass and energy balances of the condensation hood. The condensate flow rate turned out to be insufficient to fulfill the energy balance while measured directly. Hence, it was calculated from heater’s power of the steam generator and the balance model was validated. The combisteamer had an unknown output, so the condensate flow rate was provided by the balance model after its validation. A preliminary diagnosis of the device was carried out as well.
Geometry of plate heat exchangers (PHE) is characterized by a complex net of narrow channels. It enhances turbulence and results in better heat transfer performance. Theoretically, larger number of channels (plates) should proportionally increase the PHE heat power capacity. In practice a nonuniform massflow distribution in consecutive flow channels can significantly deteriorate the overall heat exchange performance. The flow maldistribution is one of the most commonly reported exploitation problems and is present in PHE with and without phase-change flows. The presented paper investigates numerically a flow pattern in PHE with evaporation of R410A refrigerant. Various sizes of PHE are considered. The paper introduces a robust methodology to transform the complicated geometry of a real 3D PHE to its 2D representation. It results in orders of magnitude faster calculations and allows for fast evaluation of different geometrical changes of PHE and their effect on flow maldistribution.