Szargut proposed the algorithm for determination of the influence of irreversibility of components of thermal process on the emission of CO2 [6]. In the presented paper, basing on Szargut's proposal, the example of analysis of influence of operational parameters of coal fired power plant on the local increase of CO2 emission is presented. The influence of operational parameters on the local exergy losses appearing in components of investigated power plant are simulating making use of the semi-empirical model of power plant.
The Bulletin of the Polish Academy of Sciences: Technical Sciences (Bull.Pol. Ac.: Tech.) is published bimonthly by the Division IV Engineering Sciences of the Polish Academy of Sciences, since the beginning of the existence of the PAS in 1952. The journal is peer‐reviewed and is published both in printed and electronic form. It is established for the publication of original high quality papers from multidisciplinary Engineering sciences with the following topics preferred: Artificial and Computational Intelligence, Biomedical Engineering and Biotechnology, Civil Engineering, Control, Informatics and Robotics, Electronics, Telecommunication and Optoelectronics, Mechanical and Aeronautical Engineering, Thermodynamics, Material Science and Nanotechnology, Power Systems and Power Electronics.
Journal Metrics: JCR Impact Factor 2018: 1.361, 5 Year Impact Factor: 1.323, SCImago Journal Rank (SJR) 2017: 0.319, Source Normalized Impact per Paper (SNIP) 2017: 1.005, CiteScore 2017: 1.27, The Polish Ministry of Science and Higher Education 2017: 25 points.
Abbreviations/Acronym: Journal citation: Bull. Pol. Ac.: Tech., ISO: Bull. Pol. Acad. Sci.-Tech. Sci., JCR Abbrev: B POL ACAD SCI-TECH Acronym in the Editorial System: BPASTS.
The paper is devoted to the problems of exergetic cost determination. A brief description of theoretical fundamentals of exergetic cost determination and its application are presented. The applied method of calculations is based on the rules of determination of cumulative exergy consumption. The additional possibilities ensured by the exergetic cost analysis in comparison to the direct exergy consumption analysis are discussed. The presented methodology was applied for the analysis of influence of operational parameters on exergetic cost indices of steam power plant. Results of calculations concern one of the modern Polish power plant unit. Basing on the obtained results several conclusions have been formulated that show advantages of application of exergetic cost analyses.
Efficiency and electrical power output of combined cycle power plants vary according to the ambient conditions. The amount of these variations greatly affects electricity production, fuel consumption, and plant incomes. Obviously, many world countries have a wide range of climatic conditions, which impact the performance of power plants. In this paper, a thermodynamic analysis of an operating power plant located in Jordan is performed with actual operating data acquired from the power plant control unit. The analysis is performed by using first and second laws of thermodynamics. Energy and exergy efficiencies of each component of the power plant system are calculated and the effect of ambient temperature on the components performance is studied. The effects of gas turbine pressure ratio, gas turbine inlet temperature, load and ambient conditions on the combined cycle efficiency, power outputs and exergy destruction are investigated. Energy and exergy efficiencies of the combined cycle power plant are found as 45.29%, and 42.73% respectively when the ambient temperature is 34 ◦C. Furthermore, it is found that the combustion chamber has the largest exergy destruction rate among the system components. The results showed that 73% of the total exergy destruction occurs in the combustion chamber when the ambient temperature is 34 ◦C. Moreover, the results show that the second major exergy loss is in HRSC. The results show that the energy and exergy efficiency of the combined cycle power plant decreases as the ambient temperature increases. According to the calculation results, improvement and modification suggestions are presented.
The new efficient method of modeling and thermodynamic analysis of power engineering systems has been presented. With its help a comparison of different structures and investigation of the influence of a particular constituent process onto the whole system efficiency is possible. The shaft work or the exergy is the main thermodynamic quantity taken into account in analyses, and the appropriate dimensionless modeling parameter has been introduced.
The article presents an experimental-theoretical analysis of fluidised-bed drying of poppy seeds directed on minimisation of energy. The analysis was performed for a complete drying node incorporating a heat exchanger and a fan. Two complementary factors were used in the exergetic evaluation: exergy efficiency and unit consumption of exergy. An analysis of drying in stationary bed was carried out for comparison purposes. Results of the exergetic analysis can become a basis for innovative works focused on decreasing energy consumption of a technological node being analysed, e.g. by the use of recirculation of fluidising-drying medium.
In this work, a new dual-evaporator CO2transcritical refrigeration cycle with two ejectors is proposed. In this new system, we proposed to recover the lost energy of condensation coming off the gas cooler and operate the refrigeration cycle ejector free and enhance the system performance and obtain dual-temperature refrigeration simultaneously. The effects of some key parameters on the thermodynamic performance of the modified cycle are theoretically investigated based on energetic and exergetic analysis. The simulation results for the modified cycle indicate more effective system performance improvement than the single ejector in the CO2vapor compression cycle using ejector as an expander ranging up to 46%. The exergetic analysis for this system is made. The performance characteristics of the proposed cycle show its promise in dual-evaporator refrigeration system.
Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5°C with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40°C, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.
In order to analyze the cumulative exergy consumption of an integrated oxy-fuel combustion power plant the method of balance equations was applied based on the principle that the cumulative exergy consumption charging the products of this process equals the sum of cumulative exergy consumption charging the substrates. The set of balance equations of the cumulative exergy consumption bases on the ‘input-output method’ of the direct energy consumption. In the structure of the balance we distinguished main products (e.g. electricity), by-products (e.g. nitrogen) and external supplies (fuels). In the balance model of cumulative exergy consumption it has been assumed that the cumulative exergy consumption charging the supplies from outside is a quantity known a priori resulting from the analysis of cumulative exergy consumption concerning the economy of the whole country. The byproducts are charged by the cumulative exergy consumption resulting from the principle of a replaced process. The cumulative exergy consumption of the main products is the final quantity.
Paper deals with theoretical analysis of possible efficiency increase of compression refrigeration cycles by means of application of a twophase ejector. Application of the two phase ejector in subcritical refrigeration system as a booster compressor is discussed in the paper. Results of exergy analysis of the system operating with various working fluids for various operating conditions have been shown. Analysis showed possible exergy efficiency increase of refrigeration compression cycle.
Oxy-fuel combustion (OFC) belongs to one of the three commonly known clean coal technologies for power generation sector and other industry sectors responsible for CO2emissions (e.g., steel or cement production). The OFC capture technology is based on using high-purity oxygen in the combustion process instead of atmospheric air. Therefore flue gases have a high concentration of CO2- Due to the limited adiabatic temperature of combustion some part of CO2must be recycled to the boiler in order to maintain a proper flame temperature. An integrated oxy-fuel combustion power plant constitutes a system consisting of the following technological modules: boiler, steam cycle, air separation unit, cooling water and water treatment system, flue gas quality control system and CO2processing unit. Due to the interconnections between technological modules, energy, exergy and ecological analyses require a system approach. The paper present the system approach based on the 'input-output' method to the analysis of the: direct energy and material consumption, cumulative energy and exergy consumption, system (local and cumulative) exergy losses, and thermoecological cost. Other measures like cumulative degree of perfection or index of sustainable development are also proposed. The paper presents a complex example of the system analysis (from direct energy consumption to thermoecological cost) of an advanced integrated OFC power plant.
This paper describes the simulation, exergy analysis and comparison of two commonly applied liquefaction of technologies natural gas, namely: propane precooled mixed refrigerant process (C3MR) and dual mixed refrigerant process (DMR) alongside two modifications of each employing end flash systems. The C3MR and DMR process schemes were simulated using the commercial software to mathematically model chemical processes. These schemes were then analysed using energy and exergy calculations to determine their performances. The exergy efficiency for the C3MR processes without end flash system, with simple end flash system and extended end flash system were evaluated as 29%, 31%, and 33%, respectively, while the exergy efficiency for the DMR processes without end flash system, with simple end flash system, and extended end flash system were evaluated as 26%, 25.5%, and 30%, respectively. The results achieved show that the extended end flash system versions of the schemes are most efficient. Furthermore, the exergy analysis depicted that the major equipment that must be enhanced in order to improve the cycle exergy efficiencies are the compressors, heat exchangers, and coolers.
For economic growth of nation, the energy plays an important role. The excessive use of fossil fuels results the increase in global warming and depleting the resources. Due to this reason, the renewable energy sources are creating more attraction for researchers. In renewable energy sector, solar energy is the most abundant and clean source of energy. In solar thermal systems, solar air heater (SAH) is the main system which is used for heating of air. As it is simple in construction and cheaper in cost, it is of main interest for the researchers. The concept of first law and second law of thermodynamics is used for the study of the energy and exergy analysis respectively. The energy analysis is of great importance for the study of process effectiveness while the exergetic analysis is another significant concept to examine the actual behavior of process involving various energy losses and internal irreversibility. For efficient utilization of solar energy, the exergy analysis is very important tool for optimal design of solar air heaters. The aim of the present work is to review the works related to energy and exergy analysis of various types of solar air heaters and to find out the research gap for future work.
The application of waste heat from exhaust gas of ship’s main engines has become widely practiced as early as in the 1930s. Thus the increase of ship’s overall efficiency was improved. Nowadays all newly built ships of the 400 gross tonnage and above must have specified energy efficiency design index, which is a measure for CO2 emissions of the ship and its impact on the environment. Therefore, the design of waste heat recovery systems requires special attention. The use of these systems is one of the basic ways to reduce CO2 emissions and to improve the ship’s energy efficiency. The paper describes the ship’s heating systems designed for the use of waste heat contained in the exhaust gas of self-ignition engines, in which the heat carriers are respectively water vapor, water or thermal oil. Selected results of comparative exergy analysis of simplified steam, water and oil heating systems have been presented. The results indicate that the oil heating system is comparable to the water system in terms of internal exergy losses. However, larger losses of exergy occur in the case of a steam system. In the steam system, a significant loss is caused by the need to cool the condensate to avoid cavitation in boiler feed pumps. This loss can in many cases cause the negative heat balance of ship during sea voyage while using only the exhaust gas boilers.