Search results

Filters

  • Journals

Search results

Number of results: 4
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Ultrasonic methods of human body internal structures imaging are being continuously enhanced. New algorithms are created to improve certain output parameters. A synthetic aperture method (SA) is an example which allows to display images at higher frame-rate than in case of conventional beam-forming method.

Higher computational complexity is a limitation of SA method and it can prevent from obtaining a desired reconstruction time. This problem can be solved by neglecting a part of data. Obviously it implies a decrease of imaging quality, however a proper data reduction technique would minimize the image degradation.

A proposed way of data reduction can be used with synthetic transmit aperture method (STA) and it bases on an assumption that a signal obtained from any pair of transducers is the same, no matter which transducer transmits and which receives. According to this postulate, nearly a half of the data can be ignored without image quality decrease.

The presented results of simulations and measurements with use of wire and tissue phantom prove that the proposed data reduction technique reduces the amount of data to be processed by half, while maintaining resolution and allowing only a small decrease of SNR and contrast of resulting images.

Go to article

Authors and Affiliations

Piotr Karwat
Marcin Lewandowski
Ziemowit Klimonda
Andrzej Nowicki
Michał Sęklewski
Download PDF Download RIS Download Bibtex

Abstract

The following work presents the idea of constructing a digitally controlled active piezoceramic transducer matrix for ultrasonic projection imaging of biological media in a similar way as in case of roentgenography (RTG). Multielement ultrasonic probes in the form of flat matrices of elementary piezoceramic transducers require attaching a large number of electrodes in order to activate the individual transducers. This paper presents the idea of minimising the number of transducer connections in an active row-column matrix system. This idea was verified by designing a model of a matrix consisting of 16 ultrasonic transducers with electrode attachments optimised by means of electronic switches in rows and columns and miniature transistor switches in the nodes of the matrix allowing to activate selected transducers. The results of measurements and simulations of parameters of the designed matrix show that it is suitable to be used in projection imaging of biological media as a sending probe. In to use the matrix as a universal sending or receiving probe, it was suggested to add further switches that would eliminate the undesired effect of crosstalks in case of switches used for toggling the transducers in the nodes of the matrix.

Go to article

Authors and Affiliations

Krzysztof Opieliński
Tadeusz Gudra
Piotr Pruchnicki
Download PDF Download RIS Download Bibtex

Abstract

Mixed boundary-value problem for periodic baffles in acoustic medium is solved with help of the method developed earlier in electrostatics. The nice feature of the method is that the resulting matrices are relatively easy for computations and that the results satisfy exactly the energy conservation law. Illustrative numerical examples present the wave-beam steering (in the far-field) in a baffle system that may be considered as a model of one-dimensional ultrasonic transducer array.

Go to article

Authors and Affiliations

Yuriy Tasinkevych
Eugeniusz Danicki
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the optimization problem for the multi-element synthetic transmit aperture method (MSTA) in ultrasound imaging applications. The optimal choice of the transmit aperture size is made as a trade-off between the lateral resolution, penetration depth and the frame rate. Results of the analysis obtained by a developed optimization algorithm are presented. The maximum penetration depth and lateral resolution at given depths are chosen as optimization criteria. The results of numerical experiments carried out in MATLAB® using synthetic aperture data of point reflectors obtained by the FIELD II simulation program are presented. The visualization of experimental synthetic aperture data of a tissue mimicking phantom and in vitro measurements of the beef liver performed using the SonixTOUCH Research system are also shown.

Go to article

Authors and Affiliations

Marcin Lewandowski
Yuriy Tasinkevych
Andrzej Nowicki
Ihor Trots

This page uses 'cookies'. Learn more