Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 3
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

In the diagnosis of many disease entities directly or indirectly related to disorders of respiratory parameters and heart disease, an important support would be to estimate the temporal changes in these parameters (most often respiratory wave (RW) and respiratory rate (RR)) on the basis the results of measurements of other physiological parameters of the patient. Such a possibility exists during ECG examination. The paper presents three methods for estimating RWand RR using ECG signal processing. The three procedures developed are shown: using Savitzky–Golay filtering (S-G), the ECG-Derived Respiration method (EDR) and the Respiratory Sinus Arrhythmia Analysis method (RSA). It must be clearly stated that the proposed methods are not designed to fully diagnose the patient’s respiratory function, but they can be applied to detect some conditions that are difficult to diagnose when performing an ECG, such as sleep-disordered breathing. The obtained results of the analysis were compared with those obtained from a dedicated measurement system developed by the authors. The second part of the paper will show the results of preliminary clinical verification of the developed analysis methods, taking into account the physiological parameters of the patient.
Go to article

Authors and Affiliations

Miroslaw Szmajda
1
Mirosław Chyliński
1
Jerzy Szacha
2
Janusz Mroczka
3

  1. Faculty of Electrical Engineering, Automatic Control and Informatics, Opole University of Technology, Prószkowska 76 Street, 45-758 Opole, Poland
  2. Faculty of Physical Education and Physiotherapy, Opole University of Technology, Prószkowska 76 Street, 45-758 Opole; Department of Cardiology, University Hospital in Opole, 45-401 Opole, Poland
  3. Faculty of Electronics, Photonics and Microsystems, Department of Electronic and Photonic Metrology, Wrocław University of Science and Technology, B. Prusa 53/55 Street, 50-317 Wrocław, Poland
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the effect of ICP-RIE etching time using one-component plasma on various parameters of an InAs/GaSb type II superlattice matrix. In the studies, two samples used at different BCl3 gas flow rates were compared and it was found that using a lower flow rate of 7 sccm results in obtaining a smoother sidewall morphology. Next, five periodic mesa-shaped structures were etched under identical conditions, but using a different time. The results indicated that the ICP-RIE method using a BCl3 flow rate of 7 sccm, ICP:RIE power ratio of 300W:270W allowed the ICP:RIE formation of a periodic mesa-shaped structure with smooth and perpendicular sidewalls.
Go to article

Authors and Affiliations

Marta Różycka
1 2
Agata Jasik
1
ORCID: ORCID
Paweł Kozłowski
1
ORCID: ORCID
Krzysztof Bracha
1
Jacek Ratajczak
1
Anna Wierzbicka-Miernik
2

  1. Łukasiewicz Research Network – Institute of Microelectronics and Photonics, 32/46 Lotników Avenue, 02-668, Warsaw, Poland
  2. Institute of Metallurgy and Materials Science, Polish Academy of Sciences, 25 Reymonta Street, 30-059, Kraków, Poland
Download PDF Download RIS Download Bibtex

Abstract

Geometrical tolerances as tricky measurands are indicated. Crucial differences between the ISO and ASME geometrical tolerancing standards are discussed. It is demonstrated that, in many cases, both systems have different default rules. Moreover, for some identical graphical indications, interpretations are different. On the other hand, the standards contain similar arrangements in many cases. It is underlined that nowadays, due to the progressing globalisation, it is necessary to know these standards, bearing in mind that suppliers or customers specify requirements according to provisions from particular standards implemented in their companies. The above justifies the need for research exploring differences and similarities in both systems of standards. It is shown that the ISO GPS system standards, due to default independency principle, prefer to set production as cheaply as possible, while ASME, due to default provisions ( e.g. Rule #1, simultaneous requirement) puts stress on controlling product geometry more strictly, which is sometimes unnecessary.
Go to article

Authors and Affiliations

Zbigniew Humienny
1
Paweł Zdrojewski
2

  1. Warsaw University of Technology, Faculty of Automotive and Construction Machinery Engineering, Institute of Machine Design Fundamentals, Narbutta 84, 02-524 Warsaw, Poland
  2. Łukasiewicz Research Network – Institute of Aviation, Aleja Krakowska 110/114, 02-256 Warsaw, Poland

This page uses 'cookies'. Learn more