Abstract

Combi-steamer condensation hoods are widely used in modern gastronomy. They condense steam produced by the combi-steamer and also filter solid particles, moisture, grease and smells. All these factors negatively affect the staff and dishes, so efficient work of the condensation hoods becomes important. A mathematical and experimental analysis of such a device is described in this paper. First a measurement methodology was designed and measurements of air humidity, temperature and mass flow rates were performed. The measurement procedure concerned dedicated a steam generator and combi-steamer. Next a mathematical model was developed. It was based on mass and energy balances of the condensation hood. The condensate flow rate turned out to be insufficient to fulfill the energy balance while measured directly. Hence, it was calculated from heater’s power of the steam generator and the balance model was validated. The combisteamer had an unknown output, so the condensate flow rate was provided by the balance model after its validation. A preliminary diagnosis of the device was carried out as well.

Go to article

Authors and Affiliations

Mieszko Tokarski
Arkadiusz Ryfa
Piotr Buliński
Marek Rojczyk
Krzysztof Ziarko
Andrzej J. Nowak
Download PDF Download RIS Download Bibtex

Abstract

This paper deals with the numerical simulation of a pilot-scale axial cyclone separator. The main purpose of this paper is to develop a numerical model that is able to foresee the cyclone separator cut-off point. This is crucial in blast furnace gas installation to capture large particles containing carbon and iron, while allowing smaller particles such as zinc and lead to pass through. The cut-off point must be designed to give a sufficiently high zinc and lead content in the sludge created after the second cleaning stage. This allows the sludge to become a commercial product. To design this cut-off point, an investigation of the influence of inlet gas velocity, temperature, and the angle of guiding vanes at the inlet was done. The developed CFD model was validated against experimental data on the fractional efficiency of the cyclone separator. The results were in good agreement with the experimental data for all parameters tested. The behavior of the particles inside the cyclone was also physically correct.
Go to article

Authors and Affiliations

Arkadiusz Ryfa
1
Mieszko Tokarski
2
Wojciech Adamczyk
1
Adam Klimanek
1
Paweł Bargiel
1
Ryszard Białecki
1
Michał Kocot
3
Harald Kania
4
Janusz Stecko
4
Marianna Czaplicka
5
ORCID: ORCID

  1. Silesian University of Technology, Institute of Thermal Technology, Konarskiego 22, 44-100 Gliwice, Poland
  2. Silesian University of Technology, Institute of Thermal Technology, Konarskiego 22, 44-100 Gliwice, Poland; AGH University of Science and Technology, Department of Fuels Technology, Czarnowiejska 30, 30-059, Kraków, Poland
  3. ArcelorMittal Poland, al. Piłsudskiego 92, 41-308 Dąbrowa Górnicza, PolandNiesler, Marian : Institute for Ferrous Metallurgy, Łukasiewicz Research Network, Karola Miarki 12, 44-100 Gliwice, Poland
  4. Institute for Ferrous Metallurgy, Łukasiewicz Research Network, Karola Miarki 12, 44-100 Gliwice, Poland
  5. Institute of Environmental Engineering, Polish Academy of Sciences, Marii Skłodowskiej-Curie 34, 41-819 Zabrze, Poland

This page uses 'cookies'. Learn more