Abstract

This paper presents a novel method of waveform generation in a single-sheet tester (SST) for measuring core losses and permeability in a steel sheet. Some improvements and modifications of the apparatus are also described. The improved way of working of a SST is important, especially in the extended range of polarization (up to 1.9 T). The system consists of hardware and software. Everything together was tested and has given good results. The proposed algorithm is described and compared to previously known methods.
Go to article

Authors and Affiliations

Tomasz Lerch
1
ORCID: ORCID
Michał Rad
1
ORCID: ORCID
Witold Rams
1

  1. Faculty of Electrical Engineering, Automatics, Computer Science, and Biomedical Engineering, AGH University of Science and Technology, al. Mickiewicza 30, 30-059 Krakow, Poland
Download PDF Download RIS Download Bibtex

Abstract

More and more street lighting deployments use LED technology as a light source. Unfortunately, the new technology also brings some challenges with it that remain unnoticed until installed at scale. This article presents issues related to capacitive reactive power consumed by LED luminaires. The problem is even more profound if the luminaire is dimmed, because it consumes capacitive reactive power, which is very undesirable in the power system. Countermeasures in terms of reactive power compensation for a luminaire working with variable power and their effects are also presented. The article also contains the results of the harmonic analysis of the LED luminaires current for full power and dimmed operation.
Go to article

Bibliography

[1] M. Traverso, S. Donatello, H. Moons, R. Rodriguez Quintero, M. Gama Caldas, O. Wolf, P. Van Tichelen, V. Van Hoof and T. Geerken, “Revision of the EU green public procurement criteria for street lighting and traffic signals - preliminary report,” EU - scientific and technical research reports June 2017. DOI: 10.2760/479108.
[2] A. Manolescu and F. Sisak, “LED source, a comparative analysis on lighting efficiency,” 2016 International Conference and Exposition on Electrical and Power Engineering (EPE), Iasi, 2016, pp. 525-528, DOI: 10.1109/ICEPE.2016.7781395.
[3] D. Jenkins and A. Bhargava, “LED Lighting: Maximizing the Reliability, Safety, and Efficiency of Light Fixtures in Hazardous Environments,” in IEEE Industry Applications Magazine, vol. 21, no. 1, pp. 64-67, Jan.-Feb. 2015, DOI: 10.1109/MIAS.2014.2345829.
[4] L.T. Doulos, A. Tsangrassoulis, P.A. Kontaxis, A. Kontadakis and F.V. Topalis, “Harvesting daylight with LED or T5 fluorescent lamps? The role of dimming,” Energy and Buildings, vol. 140. pp. 336-347, April 2017 DOI: 10.1016/j.enbuild.2017.02.013.
[5] G. Gagliardi, M. Lupia, G. Cario, F. Tedesco, F. Cicchello Gaccio, F. Lo Scudo and A. Casavola, “Advanced Adaptive Street Lighting Systems for Smart Cities,” Smart Cities 2020, vol. 3, pp. 1495-1512, November 2020, DOI: 10.3390/smartcities3040071.
[6] B.A. Portnov, R. Saad and T. Trop, “Interactive Scenario-Based Assessment Approach of Urban Street Lighting and Its Application to Estimating Energy Saving Benefits,” Energies 14, no. 2: 378. DOI: 10.3390/en14020378.
[7] Ł. Kosicki and D. Typańska, “Badanie odkształceń prądów i napięć generowanych przez oprawy z diodami LED,” Poznan university of technology academic journals, Electrical Engineering 2017, 92, 215-226.
[8] A. Djuretic, V. Skerovic, N. Arsic and M. Kostic, “Luminous flux to input power ratio, power factor and harmonics when dimming high-pressure sodium and LED luminaires used in road lighting,” Lighting Research & Technology, 2019. 51(2), 304–323. DOI: 10.1177/1477153518777272.
[9] A. Djuretic and M. Kostic, “Actual energy savings when replacing high-pressure sodium with LED luminaires in street lighting,” Energy 2018, vol. 157, pp. 367–378. DOI: 10.1016/j.energy.2018.05.179
[10] T. Lerch, M. Rad and I. Wojnicki, "Selected power quality issues of LED street lighting," 2020 12th International Conference and Exhibition on Electrical Power Quality and Utilisation- (EPQU), Cracow, Poland, 2020, pp. 1-4, DOI: 10.1109/EPQU50182.2020.9220310.
[11] F. A. Karim, M. Ramdhani and E. Kurniawan, "Low pass filter installation for reducing harmonic current emissions from LED lamps based on EMC standard," 2016 International Conference on Control, Electronics, Renewable Energy and Communications (ICCEREC), Bandung, 2016, pp. 132-135, DOI: 10.1109/ICCEREC.2016.7814966.
[12] L. S. Czarnecki, "Considerations on the Reactive Power in Nonsinusoidal Situations," in IEEE Transactions on Instrumentation and Measurement, vol. IM-34, no. 3, pp. 399-404, Sept. 1985, DOI: 10.1109/TIM.1985.4315358.
[13] D. Vieira, R. A. Shayani and M. A. G. de Oliveira, "Reactive Power Billing Under Nonsinusoidal Conditions for Low-Voltage Systems," in IEEE Transactions on Instrumentation and Measurement, vol. 66, no. 8, pp. 2004-2011, Aug. 2017, DOI: 10.1109/TIM.2017.2673058.
[14] C.I. Budeanu, “Puissances reactives et fictives,” Instytut Romain de l'Energie, Bucharest, Romania. 1927.
[15] D. Jeltsema, "Budeanu's concept of reactive and distortion power revisited," 2015 International School on Nonsinusoidal Currents and Compensation (ISNCC), Lagow, 2015, pp. 1-6, DOI: 10.1109/ISNCC.2015.7174697.
[16] IEC 61000-3-2 – “Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase),” 2019
[17] R. Nawrowski, Z. Stein and M. Zielińska, “Analiza wpływu przekraczania dopuszczalnych wartości współczynnika mocy w sieci nn na pracę systemu elektroenergetycznego,” Poznan University of Technology Academic Journals, Electrical Engineering 2013, 74, 111-117.
[18] IEEE 519-1992 - IEEE “Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems,” 1993.
[19] S. Ernst, L. Kotulski, T. Lerch, M. Rad, A. Sȩdziwy and I. Wojnicki “Calculating Reactive Power Compensation for Large-Scale Street Lighting”, Computational Science – ICCS 2020. Amsterdam, June 2020, vol 12138. DOI: 10.1007/978-3-030-50417-5_40.
Go to article

Authors and Affiliations

Tomasz Lerch
1
ORCID: ORCID
Michał Rad
1
ORCID: ORCID
Igor Wojnicki
1

  1. AGH University of Science and Technology, Krakow, Poland
Download PDF Download RIS Download Bibtex

Abstract

Unintentional islanding detection is one the mandatory criterion that must be met by PV inverters before connecting them into the grid. Acceptable time for inverter for islanding detection is less than 2 seconds. In this paper voltage parameters after islanding occurrence and before turning off the inverter are analyzed. In order to simulate islanding state and perform measurements the testing system was build. Three different commercial PV inverters were tested. Measured signals were used to calculate voltage envelope, phasor, frequency and ROCOF. Collected data proved to be helpful to compere different inverters.
Go to article

Bibliography

[1] S. Barczentewicz, A Bień, K. Duda , „The use of PMU data for detecting and monitoring selected electromagnetic disturbances”, International Journal od Electronics and Telecommunication. 2020, https://doi.org/10.24425/ijet.2020.134040
[2] IEEE Standard for Synchrophasor Measurements for Power Systems—Amendment 1: Modification of Selected Performance Requirements, IEEE Standard C37.118.1a, Apr. 2014.
[3] International Standard Synchrophasor for power systems – Measurements, IEC/IEEE 60255-118-1, Edition 1.0, Dec. 2018.
[4] G. A. Dileep, “Survey on smart grid technologies and applications”, Renewable Energy, vol. 146, pp. 2589-2625, 2020, https://doi.org/10.1016/j.renene.2019.08.092
[5] S. Barczentewicz, T. Lerch, A. Bień, K. Duda, “Laboratory Evaluation of a Phasor-Based Islanding Detection Method”. Energies. 2021; 14(7):1953. https://doi.org/10.3390/en14071953
[6] IEEE 15471-2020 „Standard Conformance Test Procedures for Equipment Interconnecting Distributed Energy Resources with Electric Power Systems and Associated Interfaces”
[7] S. Raza, H. Arof, H. Mokhlis, H. Mohamad, H. Azil Illias, “Passive islanding detection technique for synchronous generators based on performance ranking of different passive parameters”. IET Gener. Transm. Distrib. 2017, 11, 4175–4183, https://doi.org/10.1049/iet-gtd.2016.0806
[8] Z. Lin, T. Xia, Y. Ye, Y. Zhang, L. Chen, Y. Liu, K. Tomsovic, T. Bilke, F. Wen, “Application of wide area measurement systems to islanding detection of bulk power systems.” IEEE Trans. Power Syst. 2013, 28, 2006–2015, https://doi.org/10.1109/TPWRS.2013.2250531
[9] S.I. Jang, K.H. Kim, “An islanding detection method for distributed generations using voltage unbalance and total harminic distrotion of current.” IEEE Trans. Power Deliv. 2004, 19, 745–752, https://doi.org/10.1109/TPWRD.2003.822964
[10] R. Teodorescu, M. Liserre, P. Rodriguez, “Grid Converters for Photovoltaic and Wind Power System” John Wiley & Sons, Ltd: Chichester, West Sussex, UK; 2011; pp. 93–96
[11] S. Murugesan, M. Venkatakirthiga, “Active Unintentional Islanding Detection Method for Multiple PMSG based DGs.” IEEE Trans. Ind. Appl. 2020, 56, 4700–4708, https://doi.org/10.1109/TIA.2020.3001504
[12] S. Murugesan, V. Murali, “Hybrid Analyzing Technique Based Active Islanding Detection for Multiple DGs.” IEEE Trans. Ind. Inform. 2019, 15, 1311–1320, https://doi.org/10.1109/TII.2018.2846025
[13] D. Sivadas, K. Vasudevan, “An Active Islanding Detection Strategy with Zero Non detection Zone for Operation in Single and Multiple Inverter Mode Using GPS Synchronized Pattern.” IEEE Trans. Ind. Electron. 2020, 67, 5554–5564, https://doi.org/10.1109/TIE.2019.2931231
[14] M. Ropp, E. Aaker, K. Haigh, J. Sabbah, “Using power line carrier communication to prevent islanding”. IEEE Photovolt. Spec. Conf. 2002, 1675–1678, https://doi.org/10.1109/PVSC.2000.916224
[15] X. Wilson, Z. Guibin, L. Chun, W. Wencong, W. Guangzhu, K. A Jacek, “Power line signaling based technique for anti-islanding protection of distributed generators-Part I: Sheme and analysis.”, IEEE Trans. Power Deliv. 2007, 22, 1758–1766, https://doi.org/10.1109/TPWRD.2007.899618
[16] Z. Ye, R. Walling, L. Garces, R. Zhou, L. Li, T. Wang, “Study and Development of Anti-Islanding Control. for Grid-Connected Inverters”; Nat. Renew. Energy Lab.: Golden, CO, USA, May 2004, NREL/ SR-560-36243.
[17] S. Katyara, A. Hashmani, B.S. Chowdhary, H.B. Musavi, A. Aleem, F.A. Chachar, M.A. Shah, “Wireless Networks for Voltage Stability Analysis and Anti-islanding Protection of Smart Grid System.” Wirel. Pers. Commun. 2020, 1–18, https://doi.org/10.1007/s11277-020-07432-w
[18] K. Duda, T.P. Zieliński, S. Barczentewicz, “Perfectly Flat-Top and Equiripple Flat-Top Cosine Windows”, IEEE Trans. Instrum. Meas. 2016, 65, 1558–1567, https://doi.org/10.1109/TIM.2016.2534398
[19] K. Duda, T.P. Zieliński, “FIR Filters Compliant with the IEEE Standard for M Class PMU”. Metrol. Meas. Syst. 2016, 23, 623–636, https://doi.org/10.1515/mms-2016-0055

Go to article