Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 4
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Due to the extensive use of nonlinear power consumers, there is currently an urgent problem of high harmonic content in power supply networks. The paper provides experimental investigations and a study of the nature of the change in the main harmonic components of the current in the neutral working wire of a three-phase four-wire network with a voltage of 0.38 kV. The purpose of this study is to compare the load readings on the amplitude-phase-frequency characteristics of the current in the neutral working wire of the 0.38 kV network with the linear and non-linear load. To study the effect of load changes on the amplitude-phase-frequency characteristics of currents in the linear and zero working wires at the input of the load node, measurements were carried out by certified electrical measuring instruments. The analysis of the results obtained for the load node whose power was formed mainly by a lighting system with fluorescent and LED lamps and a system of office electrical receivers (computers, copiers, printers, scanners, etc.) was performed. It can be concluded that a current comparable to the currents of the linear wires of the network flows from the load node with the predominant nonlinear power receivers through the zero-working wire. At the same time, in the zero-working wire of the network, the third harmonic currents prevail over the main frequency currents.
Go to article

Bibliography

[1] Golub I., Boloev E., Methods of linear and nonlinear state estimation of distribution network, Proceedings of E3S Web of Conferences, Irkutsk, Russian Federation (2018).
[2] Grigoriev O.A., Petukhov V.S., Sokolov V.A., Krasilov I.A., On the impact of electronic equipment on power networks, Computer Press 1, http://www.compress.ru/article.aspx?id=9553&iid=404 (2003).
[3] Om P.M., Abdul G.S., Neeraj G., Acritical review of detection and classification of power quality events, Renewable and Sustainable Energy Reviews, no. 41, pp. 495–505 (2015).
[4] Daus Y.V., Yudaev I.V., Taranov M.A., Voronin S.M., Gazalov V.S., Reducing the costs for consumed electricity through the solar energy utilization, International Journal of Energy Economics and Policy, vol. 9, no. 2, pp. 19–23 (2019).
[5] Ded A.V., To the problem of the current state of the levels of indices of asymmetry of voltages and currents in networks of 0.4 kV, Omsk Scientific Herald, vol. 2, no. 152, pp. 63–65 (2017).
[6] Kosoukhov F.D., Vasiliev N.V., Kuznetsova E.S., New scientific directions in energy saving in threephase transformers and four-wire lines with asymmetric, non-linear and reactive loads, News of St. Petersburg State Agrarian University, vol. 2, no. 47, pp. 300–309 (2017).
[7] Belitsky A.A., Shklyarsky Y.E., Estimation of additional power losses in networks with non-linear and asymmetric load, Bulletin of Tula State University, Technical Science, no. 7, pp. 86–93 (2018).
[8] Deokar S.A., Waghmare L.M., Analysis of distribution transformer performance un-der non-linear balanced load conditions and it’s remedial, International Journal of Technology and Advanced Engineering, vol. 1, no. 2, pp. 152–161 (2011).
[9] Corasaniti V.F., Barbieri M.B., Arnera P.L., Valla M.I., Characteristics of the loads in medium voltage networks from the point of view using active filters, in IEEE PES Transmission and Distribution Conference and Exposition, pp. 1–7 (2006).
[10] Ge J., Shuai Z., Zhao H., Shen Z.J., Generalized power and current control for three-phase fourwire converter under unbalanced grid conditions, Procceding of the IECON, Lisbon, Portugal, pp. 3900–3905 (2019).
[11] Szulborski M., Kolimas Ł., Łapczynski S., Szczęśniak P., Single phase UPS systems loaded with nonlinear circuits: Analysis of topology in the context of electric power quality, Archives of Electrical Engineering, vol. 68, no. 4, pp. 787–802 (2019).
[12] Barutskov I.B., Vdovenko S.A., Tsygankov E.V., Harmonic distortion during operation of frequency converters, Chief Power Engineer, no. 6, pp. 5–13 (2011).
[13] Om P.M., Abdul G.S., Topological aspects of power quality improvement techniques: A comprehensive overview, Renewable and Sustainable Energy Reviews, no. 58, pp. 1129–1142 (2016).
[14] Bodart M., Denejer A., Keppens A., Rikart U.R., Rojzin B., Characteristics of compact fluorescent lamps with integrated ballasts and their comparison with incandescent lamps, Lighting Engineering, no. 2, pp. 18–24 (2010).
[15] Suslov K.V., Stepanov V.S., Solonina N.N., Effect of high harmonics on electricity consumers in distribution networks, in 2013 International Symposium on Electromagnetic Compatibility (EMC Europe 2013), pp. 841–845 (2013).
[16] Fursanov M.I., Zalotoy A.A., Makarevich V.V., Calculation of technological consumption (loss) of electricity in modern 0.38-10 kV electrical distribution networks, Energetika, Proceedings of CIS Higher Education Institutions and Power Engineering Associations, vol. 61, no. 5, pp. 408–422 (2018).
[17] Florkowski M., Florkowska B., Zydron P., High voltage harmonics induced modifications of PD phase-resolved patterns, Archives of Electrical Engineering, vol. 67, no. 2, pp. 231–246 (2018).
[18] European Standard EN 62040-3, https://files.stroyinf.ru/Data/704/70439.pdf (2018).
[19] Zeng X.J., Zhai H.F., Wang M.X., Yang M., Wang M.Q., A system optimization method for mitigating three-phase imbalance in distribution network, International Journal of Electrical Power and Energy Systems, no. 113, pp. 618–633 (2019).
Go to article

Authors and Affiliations

Igor V. Yudaev
1
Evgeny V. Rud
2
Mikhail A. Yundin
1
Tamara Z. Ponomarenko
2
Aleksandra M. Isupova
1

  1. Azov-Black Sea Engineering Institute of Don State Agrarian University, Russia
  2. ICPE Energy Institute for Advanced Studies of the PJSC “Kubanenergo”, Russia
Download PDF Download RIS Download Bibtex

Abstract

In the paper, a procedure for precise and expedited design optimization of unequal power split patch couplers is proposed. Our methodology aims at identifying the coupler dimensions that correspond to the circuit operating at the requested frequency and featuring a required power split. At the same time, the design process is supposed to be computationally efficient. The proposed methodology involves two types of auxiliary models (surrogates): an inverse one, constructed from a set of reference designs optimized for particular power split values, and a forward one which represents the circuit S-parameter gradients as a function of the power split ratio. The inverse model directly yields the values of geometry parameters of the coupler for any required power split, whereas the forward model is used for a post-scaling correction of the circuit characteristics. For the sake of illustration, a 10-GHz circular sector patch coupler is considered. The power split ratio of the structure is re-designed within a wide range of ��6 dB to 0 dB. As demonstrated, precise scaling (with the power split error smaller than 0.02 dB and the operating frequency error not exceeding 0.05 GHz) can be achieved at the cost of less than three full-wave EM simulations of the coupler. Numerical results are validated experimentally.

Go to article

Authors and Affiliations

Slawomir Koziel
Adrian Bekasiewicz
Download PDF Download RIS Download Bibtex

Abstract

Electrophoretic methods were used to identify protein complexes formed between ostrich egg yolk lipoprotein fractions (LPFo) with seminal plasma (SP) of fractionated ejaculates, and to investigate the effect of these complexes on boar semen quality after cryopreservation. Chromatographic SP fractions (F1, F2 and F3), with or without LPFo solution, were subjected to sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) analysis. Comparative electrophoretic analyses of the SP revealed marked differences in the SDS-PAGE protein profiles among boars. Electrophoretic analyses showed that the interactions of LPFo with SP resulted in the appearance of high-intensity protein bands. Spermatozoa were exposed to SP chromatographic fractions originating from F1, F2 and F3, and the whole SP (wSP) before being frozen. Spermatozoa exposed to F1 and F2 exhibited significantly higher post-thaw motility compared to those treated with either F3 or wSP. In most of the boars the proportions of membrane-intact frozen-thawed spermatozoa differed among the treatments, being significantly lower in the wSP-treated samples. The incidence of frozen-thawed spermatozoa with DNA fragmentation was less prevalent in samples exposed to F3 or the wSP. The results of this study confirmed that the interactions of LPFo with fractionated SP during the cooling period contributed to alterations in the sperm membranes, rendering them less susceptible to temperature-related injury.

Go to article

Authors and Affiliations

L. Fraser
Ł. Zasiadczyk
J. Strzeżek
W. Kordan
A. Mańkowska
Download PDF Download RIS Download Bibtex

Abstract

Two vibrating circular membranes radiate acoustic waves into the region bounded by three infinite baffles arranged perpendicularly to one another. The Neumann boundary value problem has been investigated in the case when both sources are embedded in the same baffle. The analyzed processes are time harmonic. The membranes vibrate asymmetrically. External excitations of different surface distributions and different phases have been applied to the sound sources’ surfaces. The influence of the radiated acoustic waves on the membranes’ vibrations has been included. The acoustic power of the sound sources system has been calculated by using a complete eigenfunctions system.

Go to article

Authors and Affiliations

Wojciech P. Rdzanek
Krzysztof Szemela
Witold J. Rdzanek

This page uses 'cookies'. Learn more