Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 2
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Effects of specimen thickness and stress ratio on fatigue crack growth and crack closure levels under constant amplitude loading and after a single overload have been studied experimentally for a structural steel ( I 8G2A). The corresponding crack growth data from the fatigue tests have been presented and evaluated. The experimental trends have been compared to those reported in the literature for various steels. The ability of the effective stress intensity factor range based on crack closure measurements to correlate the observed crack growth response has been investigated.
Go to article

Authors and Affiliations

Małgorzata Skorupa
Andrzej Skorupa
Jaap Schijve
Tomasz Machniewicz
Paweł Korbut
Download PDF Download RIS Download Bibtex

Abstract

The aim of this document is to present the topic of modeling district heating systems in order to enable optimization of their operation, with special focus on thermal energy storage in the pipelines. Two mathematical models for simulation of transient behavior of district heating networks have been described, and their results have been compared in a case study. The operational optimization in a DH system, especially if this system is supplied from a combined heat and power plant, is a difficult and complicated task. Finding a global financial optimum requires considering long periods of time and including thermal energy storage possibilities into consideration. One of the most interesting options for thermal energy storage is utilization of thermal inertia of the network itself. This approach requires no additional investment, while providing significant possibilities for heat load shifting. It is not feasible to use full topological models of the networks, comprising thousands of substations and network sections, for the purpose of operational optimization with thermal energy storage, because such models require long calculation times. In order to optimize planned thermal energy storage actions, it is necessary to model the transient behavior of the network in a very simple way – allowing for fast and reliable calculations. Two approaches to building such models have been presented. Both have been tested by comparing the results of simulation of the behavior of the same network. The characteristic features, advantages and disadvantages of both kinds of models have been identified. The results can prove useful for district heating system operators in the near future.

Go to article

Authors and Affiliations

Michał Leśko
Wojciech Bujalski

This page uses 'cookies'. Learn more