Search results

Filters

  • Journals
  • Authors
  • Keywords
  • Date
  • Type

Search results

Number of results: 1
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

This study focused on the fatigue and corrosion fatigue of maraging steel 18Ni (250). The 18Ni (250) samples were tested for axial fatigue in air and 3.5% NaCl solution. The effects of loading frequency and stress ratio on the fatigue strength of 18Ni (250) were studied. In air, the loading frequency was 10 Hz, and the stress ratio was 0.5. However, three loading methods were used in the 3.5% NaCl solution: (i) the loading frequency of 1 Hz and stress ratio of 0.5; (ii) the loading frequency of 1 Hz and stress ratio 0.1, and (iii) the loading frequency 5 Hz and stress ratio 0.5. The corrosion fatigue strength of samples in the 3.5% NaCl solution was 63.3% lower than that of the samples in air. The fractures in the samples were observed after the test.
Go to article

Authors and Affiliations

Zhu Yongmei
1
Chen Junjie
1
Tang Wenxian
1
Cui Weicheng
2 3
Wang Xiaorong
1
Wang Fang
2
Yin Baoji
1

  1. Jiangsu University of Science and Technology, College of Mechanical Engineering, Zhenjiang 212003, China
  2. College of Engineering Science and Technology, Shanghai Ocean University, Shanghai 201306, China
  3. Westlake University, School of Engineering, Hangzhou 310024, China

This page uses 'cookies'. Learn more