N2 - The paper presents proposal of a model of the fluidized bed boiler adapted for use in model-based controllers e.g. predictive, adaptive or internal model control (IMC). The model has been derived in the form of transfer function matrix which allows its direct implementation in the controller structure. Formulated model takes into consideration the principal cross-coupling between process variables which enables the opportunity to search for feasibility of decoupling control. The results of the identification of the dynamics of the 2 MW industrial bubbling fluidized bed boiler using the proposed model form was presented. According to the experimental data it was found that despite of introduced simplifications presented model allows the boiler behavior prediction. L1 - http://www.czasopisma.pan.pl/Content/94269/PDF/17_paper.pdf L2 - http://www.czasopisma.pan.pl/Content/94269 PY - 2011 IS - No 3 December EP - 261 DO - 10.2478/v10173-011-0026-0 KW - Bubbling fluidized bed boiler KW - Transfer function matrix KW - System identification A1 - Porzuczek, Jan PB - The Committee of Thermodynamics and Combustion of the Polish Academy of Sciences and The Institute of Fluid-Flow Machinery Polish Academy of Sciences DA - 2011 T1 - Transfer function matrix model of the bubbling fluidized bed boiler SP - 245 UR - http://www.czasopisma.pan.pl/dlibra/publication/edition/94269 T2 - Archives of Thermodynamics