TY - JOUR N2 - Measurement of the perfusion coefficient and thermal parameters of skin tissue using dynamic thermography is presented in this paper. A novel approach based on cold provocation and thermal modelling of skin tissue is presented. The measurement was performed on a person’s forearm using a special cooling device equipped with the Peltier module. The proposed method first cools the skin, and then measures the changes of its temperature matching the measurement results with a heat transfer model to estimate the skin perfusion and other thermal parameters. In order to assess correctness of the proposed approach, the uncertainty analysis was performed. L1 - http://www.czasopisma.pan.pl/Content/106338/PDF/10.15.15mms-2016-0032%20paper%2005.pdf L2 - http://www.czasopisma.pan.pl/Content/106338 PY - 2016 IS - No 3 EP - 381 DO - 10.1515/mms-2016-0032 KW - active thermovision KW - perfusion KW - thermal model KW - skin tissue KW - measurement uncertainty A1 - Strąkowska, Maria A1 - Strąkowski, Robert A1 - Strzelecki, Michał A1 - de Mey, Gilbert A1 - Więcek, Bogusław PB - Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation VL - vol. 23 DA - 2016.09.30 T1 - Evaluation of Perfusion and Thermal Parameters of Skin Tissue Using Cold Provocation and Thermographic Measurements SP - 373 UR - http://www.czasopisma.pan.pl/dlibra/publication/edition/106338 T2 - Metrology and Measurement Systems ER -